4 3 position exhaust center 10-SY7000 02 02 03 1 4 S 5 VDC 5 3 position pressure center Note 1) : Enter a symbol for cable length.
For manifold type 30, 31 Large flow type (Cv: 0.012) 1 SY1 3 A 5 L M3 : Body ported Large flow type (Cv: 0.012) 5 SY1 4 A M 1 : Base mounted 3 port Rated voltage Port size 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Nil: Without sub-plate M3: With sub-plate Sub-plate type For manifold type S41 Large flow type (With gasket and screws) Electrical entry Manual override 24 V, 12 V, 6 V, 5 V, 3
-06 02 03 04 06 E400E500-06 Piping adapter Note 5) E20001 02 03 E30002 03 04 E30002 03 04 02 03 04 06 IS1000E-40 Pressure switch with piping adapter Note 5) IS1000E-20 01 02 03 IS1000E-30 02 03 04 IS1000E-30 02 03 04 Cross interface Note 5) Y2401 02 Y3401 02 Y3401 02 Y4402 03 Y5403 04 Note 1) in part number for the round pressure gauge indicates a type of connection thread.
AW+AL+V AF+AR+V AF+AFM+AR+V AW+AFM+V AC2001 to AC4001 AC2011 to AC4011 Residual pressure exhaust 3 port valve V AC2021 to AC4021 AC2031 to AC4031 Port size AC2041 to AC4041 01 02 03 04 1/8 1/4 3/8 1/2 Note 5) If indicating more than one symbol, place the desired symbols in alphabetical order.
N.C. 0.2MPa Note 2) Note 3) Float type auto drain Spacer Pressure switch Note 5) Note 4) Note 5) T-interface Y21001 (02) Y310(01) 02 Y310(01) 02 Y410(02) 03 Y510(02) 03 Note 5) 02 03 04 01 02 VHS302 03 VHS2000VHS302 03 VHS40003-port valve for residual pressure release 02 03 04 06 02 03 04 06 01 02 Y3401 02 01 02 03 E30002 03 04 E30002 03 04 E200E400E500-06 Note 5) Piping adapter Note 5) 01
110 V [115 V] 200 V 220 V [230 V] 1 (P) 1 (P) 5 (R1) 3 (R2) 3 (R) Apparent power VA 2 position double 2 position double AC (B) 2 (A) 4 (A) 4 (B) 2 Diode (DIN terminal, Varistor when non-polar types) LED (Neon light when AC with DIN terminal) Surge voltage suppressor Indicator light 1 (P) 5 (R1) 3 (R2) 1 (P) 3 (R) In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
3 4 5 Scale: 35% G H L type plug connector (L): SY7 40(R)-LM type plug connector (M): SY7 40(R)-MDIN terminal (D): SY7 40(R)-D02 03 3 4 5 3 4 5 02 03 02 03 3 4 5 Manifold spec. sheets Order made Type 45 Type 45Applicable cable O.D. 3.5 to 7 91.5 84 172.4 Max. 10 72.7 Pg.7 20.5 20.5 174.2 33 60.6 11.5 26.5 Grommet .
V 48 V 230 V 24 V 12 V 02 (1/4) 03 (3/8) 02 (1/4) 03 (3/8) AC Normally Open (N.O.)
V 200 V 110 V 220 V 240 V 48 V 230 V 24 V 12 V 02 (1/4) 03 (3/8) 02 (1/4) 03 (3/8) AC Note) Note) Note) The orifice diameter shown above are for the supply pressure side/ vacuum side port.
station 5 station 5 station 5 station VFS Connector terminal no.
(Z) DC AC 3-wire (NPN) 3-wire (PNP) 2-wire M9N M9P M9B A90 A93 5 V, 12 V Solid state switch Relay, PLC 24 V Grommet Yes 12 V 5 V, 12 V 12 V 100 V or less 100 V IC circuit no Yes Relay, PLC 24 V 2-wire Reed switch Grommet 161 Sine Rodless Cylinder/Direct Mount Type Series REAR 10, 15 Replacement Procedure is P.316 Construction @2 @3 @6 @7 !
pin) socket Note 1) Input channel 2 channels (1 channel/connector) Supplied voltage 24 VDC Max. supplied current 0.5 A/connector Protection Short-circuit protection Input Output 0 to 10 V, 1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA 12 bit resolution Input signal range 10 to 10 V, 5 to 5 V 20 to 20 mA 16 bit resolution EX600-AXA 15 V 22 mA Note 2) Max. rated input signal 50 100 k Input impedance
3.5 1.5 M 30 41 50 N 51 64 81 Q 24 35 40 U 5 7 7 V 33 45 50 W 34.5 41 AC21 AC31 AC41 * Without relief valve option ** With relief valve option mm AC-A A* 90 117 154 AA** 140 181 238 B 160 220 239 C 73 86 92 E 30 38 F 45.5 58.5 75.5 G 40 55 80 J 26 29.5 37.5 K 5 3.5 1.5 M 30 41 50 N 51 64 81 Q 24 35 40 U 5 7 7 V 33 45 50 W 34.5 41 AC21A AC31A AC41A * Without relief valve option ** With
Face seal Sealant 1 A One-touch Fittings KQ2 Series Metric size Inch size 2 3.2 4 6 8 10 12 16 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Oval Type From P.5 V V V V V V Round Type From P.101 V V V V V V V V V V V V V V V Refer to the next page for details on the applicable tubing sizes of each shape.
Example) AFM30-03BD-CR-A AFD A 30 03 BD q r t w e q Symbol Description 20 30 40 Body size Nil N Note 1) Rc NPT G w Thread type F Note 2) + 01 02 03 04 06 1/8 1/4 3/8 1/2 3/4 Port size e + Nil B Note 3) a Without mounting option With bracket Mounting + Option r Nil C Note 4) D Note 5) Float type auto drain b Without auto drain N.C.
VDC, 5 A Error signal ... 220 VAC, 1 A 24 VDC, 0.5 A Minimum current value: 20 V, 5 mA (AC/DC) for operating and error signals.
Body type 5 TS Directional Control Equipment Valve option TZ General Vacuum/Low pressure V Nil V DL DS Port size (IN/OUT port) DZ Port size Rc (Nominal size) VP3145 VP3165 VP3185 Symbol VP3145 VP3165 VP3185 Optional 03 04 06 10 12 14 20 (10A) 3/8 (15A) 1/2 (20A) 3/4 (25A) 1 03 04 Rated coil voltage 06 10 12 14 20 1 2 3 1 100VAC, 50/60Hz 200VAC, 50/60Hz 110VAC, 50/60Hz 220VAC, 50/60Hz 24VDC
110 V [115 V] 200 V 220 V [230 V] (R1)5 1 (P) 3(R2) 1 (P) (R)3 AC Apparent power (VA) 2 position double 2 position double 2(B) (A)4 4(A) (B)2 Diode (DIN terminal, Varistor when non-polar types) LED (Neon light when AC with DIN terminal) Surge voltage suppressor Indicator light (R1)5 1 (P) 3(R2) (R)3 1 (P) Common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
(The SI unit type is provided for use in Japan.) 01 02 03 04 06 10 1/8 V 1/4 V V V 3/8 V V 1/2 V 3/4 V V 1 V 17 Series AC Spacers and Brackets Accessories Spacer (X) D Center of F.R.L. body C 1 X-X B X RELEASE 2 Y200 Y400 X Applicable model A 6 3 4 5 5 B 27 35.5 47 57 61 C 15 18.5 26 31 33 D 33 48 59 65 70 Model Y100 Y200 Y300 Y400 Y500 Seal AC10, AC10A, AC10B AC20 AC25, AC30 AC40 AC40-
Normally closed Normally open Normally closed Normally open 10/12 16 0.1 AC125 AC250 DC8 DC14 DC30 DC125 DC250 5 5 5 5 5 0.4 0.3 1.5 1 0.7 0.5 4 4 2.5 1.5 1.3 0.8 3 3 3 0.1 0.05 0.05 0.04 5 4 3 3 3 0.1 0.05 06/08 Pressure drop (MPa) 4 4 0.4 0.3 0.03 0.02 03/04 Precautions 1.