View D-D D-A73C D-F7V Bore size (mm) C95 D-J79/F7V/F79W/F7WV, D-J79C/F7BA/F7PW, D-J79W D-A79W D-F79F D-A7/A8 D-J79C D-A79W D-A7/A8 Cylinder series D-F7WV D-A80C 63 to 100 Width across flats HT Reinforcing bracket Mounted in case of 301 mm or longer strokes.
BBA2: For D-A7/A8/F7/J7 types The stainless steel screws described above are used when the D-F7BAL switch is shipped mounted on to the cylinder.
BBA2: For D-A7/A8/F7/J7 D-F7BAL switch is set on the cylinder with the stainless steel screws above when shipped.
U Auto switch K M L B + Stroke A + Stroke E J S Note) This drawings above show type D-A7 and D-A8 reed switches. The values shown inside ( ) are for switches other than types D-A7 and D-A8. S and U dimensions for connector type auto switches (D-A7C, D-A80C, and D-J79C) are 7mm greater.
Pad dia. 10 13 16 20 25 32 40 50 Buffer stroke 10 mm 20 mm 30 mm 40 mm 50 mm Inclination 15 (Rotation 30 ) 708 Vacuum Pad: Ball Joint Type Vertical Vacuum Entry Without Buffer/Male Thread ZPT Series How to Order ZPT 25 F GN B5 A8 Mounting Pad diameter Symbol Mounting Pad dia. 10 10 A8 M8 x 1 10 to 16 13 13 A10 M10 x 1 20 to 32 16 16 A14 M14 x 1 40, 50 20 20 25 25 Vacuum entry port 32 32 40
Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw RS H A 20, 25 BQ-1 (M3 x 0.5 x 8l) Square nut D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W RZQ Switch mounting screw 32, 40 50, 63 Magnetic body (Steel plate, etc.)
Features 1 Series ZPT Without Buffer/Male Thread Vertical Vacuum Entry How to Order ZPT 25 F GN B5 A8 Mounting thread diameter male thread Pad diameter (mm) Symbol Thread Pad dia.
ZPT20F-B5-A10 10 12 10 12.5 37.5 20 22 1.5 12.5 15.5 48.5 ZPT13F-B5-A8 ZPT25F-B5-A10 13 15 25 28 ZP 10.5 13 38 ZPT16F-B5-A8 ZPT32F-B5-A10 2 13 16 49 16 18 32 35 ZCU 40 50 ZPT F-B5-A14 (Without buffer/Male thread) AMJ Misc.
BBA2: For D-A7/A8/F7/J7 The above stainless steel screw kit is used for water resistant auto switch types D-F7BAL and F7BAVL when they are shipped mounted on a cylinder. When only a switch is shipped independently, BBA2 screws are attached.
BBA2: For D-A7/A8/F7/J7 D-F7BAL/F7BAVL switch is set on the cylinder with the stainless steel screws above when shipped.
U Q P Front cylinder port P Rear cylinder port H effective thread depth C F V I D M E 22 11 Z T Minimum lead wire bending radius 10 Auto switch D-A7, A8 Dust cover (manual unlocking unit) 4-OA counter bore N 4-OB counter bore BP unlocking port (unlocks when pressurized) K Flat washer 4 pcs.
U Q P Front cylinder port P Rear cylinder port H effective thread depth C F V I D M E 22 11 Z T Minimum lead wire bending radius 10 Auto switch D-A7, A8 Dust cover (manual unlocking unit) 4-OA counter bore N 4-OB counter bore BP unlocking port (unlocks when pressurized) K Flat washer 4 pcs.
D-A7/A8, D-A7lH/A80H, D-A73C, A80C, D-C7/C8, D-C73C/C80C, D-E7lA, E80A, D-Z7/Z8, D-9/9lA, D-A9/A9lV, and D-A79W type Use an auto switch with a contact protection box in any case listed below. Unless using a contact protection box, the contact life may be shortened. (Due to permanent energizing conditions.)
2 54 32.5 110 57 12.5 3.5 34.2 75 12.5 5 8 9 M8x1.25 2 10 M8x1.25 10.4 17.5 10.5 67 5 5.5 170 5 22 16 17 MSQB70 3.5 27 59 2 59 37.5 130 66 14.5 4.5 34.3 86 14.5 6 8 12 M8x1.25 2 10 M10x1.5 10.4 17.5 10.5 77 6 6.5 189 6 24 19 17 MSQB100 5.5 32 MSQB200 74 2 69 44 150 80 16.5 4.5 40.2 106 16.5 9 8 15 M12x1.75 2 13 M12x1.75 14.2 20 12.5 90 8 8.5 240 8 32 24 24 A11 A9 CC Model AA BB FF OO A5 A8
ZR ZM Symbol Pad dia. 1 02 to 08 ZH 2 10 to 16 3 20 to 32 ZU 4 40, 50 ZL N6 A8 4 ZP Y [qY type adaptor] ZF ZP ZCU With Buffer Vacuum related ZP 50 K20 Y A14 U6 UGN [Pad model no.] Buffer connection thread Symbol Thread dia. 1 A8 Symbol Pad dia. 1 02 to 08 2 A10 B5 3 A14 2 10 to 16 3 20 to 32 B8 4 40, 50 4 ZP U6 B8 Y [qY type adaptor] B 3 ZP K20 [wBuffer] 3.8-63
Example of Selection from Minimum Operating Flow 100 Example) Vacuum saving valve used: ZP2V-A8-05 From Table 1, Q2 can be calculated as 5.0 l/min (ANR). 90 31 {l/min (ANR)} 5 {l/min (ANR)} 80 N = 6 (unit) Vacuum pressure (kPa) 70 Q2 = 5.0 l/min (ANR) 60 Table 1.
BBA2: For D-A7/A8/F7/J7 D-F7BAL/F7BAVL switch is set on the cylinder with the stainless steel screws above when shipped. When a switch is shipped independently, BBA2 screws are attached. 10-8-4 5 Stopper Cylinder: Fixed Mounting Height Series RSQ Weight Mounting Bolt for RSQB (kg) Mounting method: Mounting bolt for throughhole mounting style of RSQB is available as an option.
For BBA2: D-A7/A8/F7/J7 D-F7BAL/F7BAVL switch is set on the cylinder with the stainless steel screws above when shipped. When a switch is shipped independently, BBA2 screws are attached.
BBA2: For D-A7/A8/F7/J7 D-F7BAL/F7BAVL switch is set on the cylinder with the stainless steel screws above when shipped.
Auto switch model 6 10 15 20 25 32 40 D-A7/A8 6 6 6 6 6 6 6 D-F7/J7 3 3 4 3 3 3 3.5 Electrical entry (Fetching direction) Type Model Features D-F79F 4.5 4.5 4.5 4.5 4.5 4.5 4.5 Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion) There may be the case it will vary substantially depending on an ambient environment.