XAH7 (mm) XL T-slot dimensions Bore size (mm) 50 80 a 11 13.3 b 17.8 20.3 c 10 12 d 6 8 e 17.5 22.5 Section XX detail 8-RR depth RL Section XX WB Z QA WA QB Section XX 4-OA through 4-OB depth of counter bore OL 4-MM depth ML 4-NN depth NL Section XX Z WA L HA T-slot for hexagon bolt X 0.02 X 0.02 DA VB VA X X T H U PW DB PB GC XAH7 depth XL 2-P (plug) XAH7 depth XL Q J K GA GB S G FB 2-P
F3 = (W + WB) x 9.8 x ( + 1) Refer to the allowable driving force table for (Fn) of data A. Determination of connection fitting weight (WB) WB > WBmax Review of connection fitting (See the standard stroke table on p.9.) WB WBmax Max.
This is a legacy product, and replaced byZSE20CF-R-M-N02-WB-X502, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KD, ZSE40/50/60 1/4 PORTED, .28660 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
l Mounting orientation m m Refer to the caution notes below.
Double clevis CT 2 x N D E M Y CD hole H10, Axis d9 RR CW CU CX +0.4 +0 T L CZ 0.1 0.3 [mm] Part no.
MXQ MXF m m MXW MXP MG MGP MGQ MGG 25/50 stroke Over 50 stroke 200 200 MGC P=0.5MPa P=0.5MPa MGPS80 MGPS80 MGF 100 100 Load weight m (kg) Load weight m (kg) CY1 MGPS50 MGPS50 50 50 MY1 40 40 30 30 20 20 10 20 30 40 50 100 200 10 10 20 30 40 50 100 200 10 Eccentric distance l (mm) Eccentric distance l (mm) 3.17-31 Series MGPS Construction !6 o i !0 !8 r !1 t !9 !2 !6e q u !4 w !7 !3 @0 !
m (kg) 80 100 80 10 10 80 5 10 20 29 30 50 49 300 200 100 5 10 20 29 30 50 49 300 200 100 Stroke (mm) Stroke (mm) 8-19-16 Compact Guide Cylinder Series MGP Horizontal Mounting (Ball bushing bearing) (19) l = 50 mm, V = 400 m/s (20) l = 100 mm, V = 400 m/s MGPL12 to 25 5 MGPL12 to 25 5 25 25 25 25 25 25 MX Load weight m (kg) Load weight m (kg) MTS 20 20 20 20 20 20 MY 16 16 16 16 16 16 CY
3 t CJ1 CJP CJ2 JCM y t CM2 CM3 CG1 CG1 20 to 32 CG3 Component Parts JMB No.
D D t D t t c e c c e e u u s u s s d i d i d i g g g o o o n n n r r r P P P A A A 1 1 9 9 9 9 9 9 w w 9 w 9 9 m I m I n n 9 9 9 u d u d a a a r u r u o s o F s tr F i e tr i e 9 9 9 D r r D r r r e e e e v v s 1 d d s 1 1 d o o i i n g n g n n n n a a H H n P n P g g r r o o i i s s d d e e u u D D c c t t d A d A r r w w a a 12-11-1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,
Inclined operation W + WB WV P PV W + WB > WV P > PV Allowable driving force table (Fn) (n = 1, 2, 3) Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (cos + sin) Inclined F3 = (W + WB) x 9.8 x ( + 1) Vertical (Refer to page 5 for vertical operation.)
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked are produced upon receipt of order. Other than the applicable auto switches listed in How to Order, the other auto switches can be mounted. For detailed specifications, refer to page 1479.
Lead wire length symbols: 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN Since there are other applicable auto switches than listed above, refer to page 6-4-24 for details.
s m s Type of impact s m 1 2 m2 Kinetic energy E1 Thrust energy E2 Fs Fs + mgs Fs mgs Absorbed energy E E1 + E2 Symbol : Speed of impact object (m/s) F: Cylinder thrust (N) s: Shock absorber stroke (m) m: Weight of impact object (kg) g: Gravitational acceleration (9.8 m/s2) Note) The speed of the impact object is measured at the time of impact with the shock absorber.
orientation Ceiling m Wall m Vertical m Note) Static load m Horizontal m M M m x g x X m x g x X m x g x Z M Static moment z y Y m x g x Y m x g x Y m x g x Z M Z m x g x X m x g x Y m x g M Note) m is a mass movable by thrust.
Inclined operation W + WB WV P PV W + WB WV P PV Allowable driving force table (Fn) (n=1,2,3) Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined (Refer to page 5 for vertical operation.)
Inclined operation W + WB WV P PV W + WB WV P PV Allowable driving force table (Fn) (n=1,2,3) Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined (Refer to page 5 for vertical operation.)
(E X C E S S I V E F O R C E I N T H E D I R E C T I O N O F R O TAT I O N A P P L I E D T O T H E P I S T O N R O D M AY D A M A G E T H E I N T E R N A L M E C H A N I S M.) R E F E R T O T H E F O L L O W I N G TA B L E F O R D I M E N S I O N S W I T H A R M 32/40/50/63S E R I E S MK2 T I G H T E N I N G T O R Q U E F O R M O U N T I N G.
6y qw t re i u !2 !3 u LEYG M LEYG L #2 #1 @9 #0 #3 #4 #5 #6 Component Parts No.
Lead wire length symbols: 0.5 m Nil (Example) Y69A 3 m L (Example) Y69AL 5 m Z (Example) Y69AZ Since there are applicable auto switches other than the listed above, refer to page 9-11-29.