Standard Type CDLS A93 A53 With Auto Switch L With auto switch Cylinder unit auto switch type Mounting brackets Number of auto switches B Basic type Tube material Nil Without auto switch L Foot type 2pcs.

Solid state switch D-F8 CUJ (As compared with SMC Series CU cylinders without magnet) Dimensions (Without magnet) Series Variations Bore size (mm) A(a) B(b) C(c) Bore size (mm) Rod end configuration Stroke (mm) Clean series 4 6 8 10 15 20 b Action Series Auto switch B Double acting Male thread Without thread None 4 10() 15() 13() 4 Single acting, Spring return 6 13(13) 19(22) 13(33) Double

Applicable load IC circuit, Relay, PLC Load voltage 24V or less 48V or less 100V or less AC DC AC DC AC DC Maximum load current 50mA 40mA 20mA Contact protection circuit None Internal resistance D-A93, D-A93V, D-A96, D-A96V (with indicator light) 1 or less (including 3m lead wire length) D-A93, D-A93V D-A96, D-A96V Auto switch part no.

Auto Switches/Proper Mounting Position at Stroke End Detection B A (mm) D-A9, D-A9V (mm) D-M9, D-M9V (mm) D-F9W, D-F9WV A A A B B B Operating range Operating range Operating range Nominal size 16 25 Nominal size 16 25 Nominal size 16 25 3 44 116 48 112 48 112 8 8.5 3.5 54 156 58 152 58 152 Auto Switch Mounting When mounting the auto switches, they should be inserted into the actuators switch

D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34(35.5) 3.5(2) 24(25.5) 6.5(8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) Note 1) The above mentioned values are indicated as a guide for auto switch mounting position for stroke end detection.

C D A B (mm) D-A9, D-A9V (mm) D-F9, D-F9V (mm) D-F9W, D-F9WV A B A B A B Bore size 16 25 32 Operating range Bore size 16 25 40 Operating range Bore size 16 25 40 Operating range 54 106 58 102 57 103 54 156 58 152 57 153 11 8.5 8.5 85 245 89 241 88 242 (mm) (mm) (mm) C D C D C D Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range 27 133

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, PIN, DBL ACT, ACTUATOR, CJP/CJP2 ROUND BODY CYLINDER, GE, 15/16MM CJP/CJP2 DBL-ACT,A-SW, .22046 lb

CRQ2X MSQX MRQ Auto Switch Working Principle [Pressure is applied from the B port.] The auto switch B is turned ON by the magnet B in the state that the pressure is applied from the B port and the piston B moves to the left side. At this time, the auto switch A turns OFF . Magnet B Piston B A port B port Auto switch B Auto switch A [Pressure is applied from the A port.]

G A A (mm) Model A 110 120 171 B 38 48 66 C 1 1 2 D 30 40 55 Fn 34 70 Fc 17 26 41 G 40 39 63 H J P.C.D L1 6 x 4.4 6 x 6.6 L2 XMC-16 XMC-25 XMC-40 40 50 65 26 28 36 P.C.D 27 P.C.D 58.7 XMC-50 to 80/Angle type C L2 D Fd Fc L1 (KF flange) Fn C (K flange) (CF flange) H J K B G A A (mm) Model A 183 209 250 B 80 100 117 C 31 39 45.5 D 75 87 114 Fn 95 110 Fd 114 Fc 52 70 83 G 77 76.5 105 H

Auto switch type Symbol Nil M9N (L) M9P (L) M9B (L) A90 (L) A93 (L) M9// Symbol Nil H0 Temperature range 5 to 60C 5 to 150C Without auto switch (without built-in magnet) Remarks Auto switch D-M9N (L) D-M9P (L) D-M9B (L) D-A90 (L) D-A93 (L) Solid state switch 6. No. of auto switches/Detecting position Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.

CDA2 B 50 200 X1184 B31J S With built-in special magnet Number of auto switches Cylinder stroke Description 2 pcs. 1 pc.

A90 A90V No Reed switch Solid state switch 2 wire 24V A93 A93V Grommet 100V 12V Yes 3 wire (NPN equiv.)

If using other screws, switch may be damaged. 12-13-16 17 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.

If using other screws, switch may be damaged. 12-13-16 17 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

LD Piping port P Operating direction A 7 Piping port P Operating direction B W K G With switch rail Q + Stroke Z + Stroke Piping port P (plug) Operating direction B HS CR HR Plug 22 8 Piping port P Operating direction B Piping port P (plug) Operating direction B 8 Piping port P Operating direction A 16 19.5 16 Plug REBR15 REBR15 (mm) A B C CB CR D F G GP GW H HA HB HC HP HR HS HT Model REBR15

(Detection at stroke end) and Its Mounting Height [mm] Auto Switch Proper Mounting Position (Standard type) Auto switch model D-Y59l D-Y69l D-Y7P D-Y7PV D-Y7H D-Y7lW D-Y7lWV D-Z7l D-Z8l D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-F5l D-J59 D-F59F D-F5NT D-A5l D-A6l D-A59W D-G39 D-K39 D-A3l D-A44 D-A9l D-A9lV D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5

38 35 42 40.5 A 33 32.5 34 31 38 36.5 49.5 48.5 A B A B A B A B 20 25 32 40 50 63 80 100 B 24 (32) 24.5 (32.5) 25 (33) 27 (36) 32 (44) 33.5 (45.5) B 14.5 (22.5) 15 (23) 15.5 (23.5) 17.5 (26.5) 22.5 (34.5) 24 (36) 29 (43) 30 (44) B 20 (28) 20.5 (28.5) 21 (29) 23 (32) 28 (40) 29.5 (41.5) B 16 (24) 16.5 (24.5) 17 (25) 19 (28) 24 (36) 25.5 (37.5) 30.5 (44.5) 31.5 (45.5) Hs 27.5 30 33.5