, D-Z76, D-Z80 Auto Switch Specifications Grommet D-Z7 (with indicator light) D-Z73 D-Z76 Auto switch part no.

mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal

mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Circuit diagram Contact input signal 2 4 1 k 11 Run/stop signal input Contact input

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.

Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10

mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal

-3No.EX-OMN0029CN-D / 1 1.5 *3) *3)1 1 -4No.EX-OMN0029CN-D () () () () -5No.EX-OMN0029CN-D / () * UL UL1310 Class2 0V -6No.EX-OMN0029CN-D * IP67 / *() SI SI () ()SI SI * IP67 M12(M8) ( ) () -7No.EX-OMN0029CN-D CE * (20 ) PLC PLC * -8No.EX-OMN0029CN-D SI 1 SI 32 10 (SI ) U SI D SI ON/OFF PNP NPN PNP NPN PNP NPN EX600 D -9No.EX-OMN0029CN-D AD 16 10 16 10 DIN

D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V 20 to 63 B A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5

AS1001F-23D-X214 AS AS-FE KE AS-FG AS-FP AS-FM AS-D AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ 743 Dual Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting ASDF-D Series RoHS Model Applicable tubing O.D.

The CNA2 series cylinder with lock?is?suitable for mid-stroke stops, emergency stops, and drop prevention. An equal holding force in extending and retracting directions make it possible to lock at either end of the stroke. High reliability and stable holding force are maintained by using a substantially lengthened brake shoe with superior wear resistance. The locking mechanism is isolated

Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R016 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.

Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R005 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.

Additionally multiple components maybe added at D. (Example: Timer and Push Button combination for an automatic return or manual return.)

Additionally multiple components maybe added at D. (Example: Timer and Push Button combination for an automatic return or manual return.)

Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.

D type DIN connector with 9.4 mm pitch between terminals is not interchangeable. To distinguish from the D type DIN connector, N is listed at the end of voltage symbol.

Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.

Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.

AS-FG AS301FS, AS311FS AS401FS, AS411FS AS-FP Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa AS-FM 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 AS-D 06, 07 1000 AS-T 500 ASP 500 ASN 0 0 5 0 10 5 0 10 AQ Number of needle rotations Number of needle rotations ASV Note) The numbers above the flow rate characteristic curves

Wiring Electrical entry Auto switch type Electrical entry from inside 3-wire D-F9P B Solid state switch D-F9 In-line 2-wire D-F9B 3-wire D-F9NW,D-F9PW In-line 2 color indication solid state switch D-F9 W 2-wire D-F9BW 3-wire D-F9NWV,D-F9PWV Perpendicular B 2-wire D-F9BWV Install auto switch as shown in figure below.