Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V
VCA20-12-1A 41 52 30 40 4.5 6 VCA30-12-1A 48 56 36 44 5.5 7 VCA40-12-1A 50 62 38 50 5.5 7 2 mounting screws (for mounting brackets) are included in bracket part no. 17-2-12 7 Series VCA Direct Operated 2 Port Solenoid Valve For Air Dimensions Grommet: G Conduit: C Q F D Q F 300 280 D VC G1/2 C R C R L VDW IN E E VQ Manual override A B B A 2-P Port size 2-P Port size VX2 VX Manual override
(mm) A B C D E F G H J L Port size Bracket part no.
cable O.D. 6 to 8 (D, DL) Pilot port B (Air operated) L (Terminal with indicator light: DL) M (Conduit terminal: T) K (DIN terminal: D) I (Grommet: G) J (Conduit: C) 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H I J K L M Model VNB5-32F VNB6-40F VNB7-50F 1 8 1 4 1 4 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 244 259.5
Applicable model H G A B C J K E D F 16.5 MXS-AT6 5 MXS 6 7 10.5 2.5 21 19 8 5 M2.5 X 8 M5 X 0.8 MXS6, MXS8 26.5 MXS-AT6-X11 15 D 16.5 MXS-AT8 5 E E H MXS 8 M3 X 10 M6 X 1 8 12.5 3 25 9 6 22.5 26.5 MXS-AT8-X11 15 36.5 MXS-AT8-X12 25 5 G 20 MXS-AT12 MXS12 12 18.5 4 32 13 8 31 M4 X 8 M8 X 1 30 MXS-AT12-X11 15 B C 40 MXS-AT12-X12 25 24.5 MXS-AT16 5 F K K F A J MXS16 M5 X 10 M10 X 1 14 23 5 40
dr to the current leakage llowing throuth the C-R element.
Adjustable range of display value fine adjustment function C Peak/Bottom value display D Keylock function Prevents operation errors such as accidentally changing setting values This function constantly detects and updates the maximum (minimum) pressure when the power is supplied, and allows to hold the maximum (minimum) pressure value.
Note 12 16 20 25 32 40 50 D-F7 , J79 D-F7 V D-J79C D-F7 W, J79W D-F7 WV D-F7BAL, F7BAVL D-F79F D-F7NTL D-F7, D-F7V D-J79, D-J79C D-F7W, D-F7WV D-J79W D-F7BAL, D-F7BAVL D-F7NTL, D-F79F -X Switch mounting screw (M3 x 0.5 x 10 ) Switch spacer Switch mounting nut D-A7 , A80 D-A73C, A80C D-A7 H, A80H D-A79W 6 6 6 32, 40 50 BQ-2 20Data D-F9W, D-F9WV D-F9BAL 5.5 3 4 5 5.5 5.5 5.5 Switch mounting
C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
Stainless Steel (mm) A B C D E F G H J L Bracket part no.
5 Super Mist Separator Series AME AME450 to AME850 Dimensions Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bracket 2-port size (Option) HA Maintenance space AT ID AMG AFF M Dimensions with mounting bracket Model Port size (Nominal size B) A H B C D E F G AM I 221
It cannot be used if connected in the opposite direction. 4.6-24 Series AME Dimensions: AME150 to AME350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4, 3/8
118.5 40 ZPT40HJ50-B01-A18 42 98 153.5 B 42 C 63 Model A 63 ZPT63HJ25-B01-A18 F 121.5 63 ZPT63HJ50-B01-A18 65 14.5 156.5 B 65 C 14.5 D 26 26 26 28 28 28 E 66 101 137 68 103 139 Y 3.5 3.5 3.5 4.5 4.5 4.5 194.5 40 ZPT40HJ75-B01-A18 42 134 189.5 63 ZPT63HJ75-B01-A18 65 14.5 192.5 50 ZPT50HJ25-B01-A18 52 63 118.5 80 ZPT80HJ25-B01-A18 83 16.5 123.5 50 ZPT50HJ50-B01-A18 52 98 153.5 80 ZPT80HJ50
dr to the current leakage llowing throuth the C-R element.
D Note 1) C Note 2) Note 1) Except double (latching) Note 1) The function symbol is D for double solenoid specifications.
A G i 2 x P Port size G A 2 x P Port size b B Conduit DIN terminal D F Q S Cable 6 to 12 G1/2 F Q 280 D G1/2 45 (42) (44) 31.5 Built-in full-wave rectifier type R C C R E J J E 2 x M depth 5 H 2 x M depth 5 B B1 H G A G A B B1 2 x P Port size 2 x P Port size Bracket mounting hole a1 (VXS23, 25) a a1 (VXS24, 26) 6.5 10.5 Dimensions (mm) Model Port size P A B B1 C D E F G H J M Bracket mounting
c Proper mounting positions (mm) A B Bore size (mm) 63 80 100 10 13 17.5 14 18.5 23.5 Proper mounting positions (mm) a b 14 18 17 c 20 24 23 d D-A9 type D-F9 type D-F9 W type 2 6 5 8 12 11 In order that adjacent switches do not misoperate, they should be set within 1mm of the proper mounting positions indicated in the table above.
(C) Outlet air press. dew point (C) Ambient temp.
D E E C G H I H V A C F U U M V E A V L Heater (Option) (Maintenance space) Auto switch (Option) B J XLA XL H XLQ XLQ G XM XY DXSA A XVD XGT CYV A (mm) Model A 120 133 178 190 B 38 48 66 79 C 1 1 2 2 D 12 11 11 E 30 40 55 75 F 17 26 41 52 G 40 39 63 68 H 87 91 129 142 J XLAQ-16 XLAQ-25 XLAQ-40 XLAQ-50 40 50 65 70 Note) The heater (Option) is not available with XLAQ-16. 471 Aluminum One-touch