SMC Corporation of America
Elite Part Number Search
Search Results "CDQSB25-10D-M9BWV"

Size, Body, Valve Type: 10D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 3A (24VDC; DIN Terminal w/Surge Voltage Suppressor w/o DIN Connector), Other Options: B (NPT Thread)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating

Clean Series: 10 (Relief Type), Magnet: D (Built-in), Bore Size: 25mm, Stroke: 10mm, Rod End Thread: Female, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Clean Series: 11 (Vacuum Suction Type), Magnet: D (Built-in), Bore Size: 25mm, Stroke: 10mm, Rod End Thread: Female, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical

Clean Series: 10 (Relief Type), Magnet: D (Built-in), Bore Size: 25mm, Stroke: 10mm, Rod End Thread: Female, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating

Clean Series: Relief Type, Magnet: Built-in, Bore Size: 25mm, Stroke: 10mm, Rod End Thread: Female, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Clean Series: Vacuum Suction Type, Magnet: Built-in, Bore Size: 25mm, Stroke: 10mm, Rod End Thread: Female, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, Lead Wire or Prewired Connector: -, Number: -

Clean Series: Relief Type, Magnet: Built-in, Bore Size: 25mm, Stroke: 10mm, Rod End Thread: Female, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 10mm, Finger Option: Standard Tapped Mounting, Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical

Bore Size: 10mm, Finger Option: Standard Tapped Mounting, Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical, Lead Wire or Prewired Connection: -

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC Yes 24 V 3-wire (NPN) 5 V, 12 V M9NAV1 M9NA1 M9NAV1 M9NA1 v v V v v IC circuit 3-wire (PNP) M9PAV1 M9PA1 M9PAV1 M9PA1 v v V v v 2-wire 12 V M9BAV1 M9BA1 M9BAV1 M9BA1 v v V v v Grommet Water resistant (2-color indicator) With diagnostic output (2-color indicator) 4-wire (NPN) 5 V, 12 V H7NF F79F V V v

Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P V V V v v Grommet 2-wire 12 V M9BV M9B V V V v v Connector H7C V V V V Terminal conduit 3-wire (NPN) 5 V, 12 V G39A V IC circuit 2-wire 12 V K39A V Solid state auto switch Relay, PLC Yes 3-wire (NPN) 5 V, 12 V M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW V V V v v 2-wire 12 V M9BWV

AC 20 to 63 80, 100 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line In-line M9NV M9N IC circuit 3-wire (NPN) G59 5 V, 12 V 3-wire (PNP) M9PV M9P G5P Grommet 2-wire 12 V M9BV M9B K59 Connector H7C Solid state auto switch M9NWV M9NW IC circuit G59W 3-wire (NPN) 5 V, 12 V Relay, PLC Yes 24 V 3-wire (PNP) M9PWV M9PW G5PW Diagnostic indication (2-color indicator) 2-wire 12 V M9BWV

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches