SMC Corporation of America
Elite Part Number Search
Search Results "CLA2B100-500-P"

NPN open collector 1 output w/analog output, 200 degrees adjustment 3 m 30 5 m 50 55 PNP open collector 1 output w/o analog output, 200 degrees adjustment 16-6-2 3 Compact Pressure Switch Series ZSE1/ISE1 Specifications ZSE1 For vacuum 0 to 101 kPa ISE1L For low pressure 0 to 100 kPa ISE1 For high pressure 0 to 1 MPa 1.5 MPa Air/Non-corrosive, non-flammable gas 12 to 24 VDC 10%, Ripple (P-P

kPa Fluid Power supply voltage Current consumption Response time Repeatability Enclosure 12 to 24 VDC 10%, Ripple (P-P) 10% or less 17 mA or less at 24 VDC 5 ms or less 1% F.S. or less IP40 Operating: 0 to 60C, Stored: 10 to 60C (With no condensation, nor freezing) Operating/Stored: 35 to 85%RH (With no condensation) ZSE ISE PSE Operating temperature range Operating humidity range Z I SE3

pressure range Regulating pressure range Proof pressure Min. regulating unit Fluid Power supply voltage Current consumption Switch output Air, Inert gas, Non-flammable gas 12 to 24 VDC, Ripple (p-p) 10% or less (With power supply polarity protection) 45 mA or less (at no load) NPN or PNP open collector output: 1 output 80 mA 30 V (With NPN output) 1 V or less (With load current of 80 mA)

Fig 9.4-4 Cooling capacity(HRS018--20) 9.4.5 HRS024--20-(BJMT) 3500 3500 Ambient Ambient 3000 3000 temperature temperature or or Cooling capacity[W] Cooling capacity[W] 2500 2500 facility water facility water temperature temperature 2000 2000 25 32 40 25 32 40 1500 1500 1000 1000 500 500 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature[] Circulating fluid temperature[]

) PFMC7501 [P_1] OUT1 250 L/min [H_1] OUT1 25 L/min 250 L/min [P_2] OUT2 25 L/min [H_2] OUT2 PFMC7102 [P_1] OUT1 500 L/min [H_1] OUT1 50 L/min 500 L/min [P_2] OUT2 50 L/min [H_2] OUT2 PFMC7202 [P_1] OUT1 1000 L/min [H_1] OUT1 100 L/min 1000 L/min [P_2] OUT2 100 L/min [H_2] OUT2 OUT1OUT2 [F 1]OUT1(29)[F 2]OUT2(47) -23No.PF-OMS0001CN-A <> 1 [P_1][n_1] [] 500 L/min OUT1OUT2[P_2

] [rEF] [Anr] 26 1 [ L] L/min [Uni] [oU1] OUT1 [HYS] [1ot] OUT1 [1_P] [ 250] 250 L/min(PFMB7501) [P_1] OUT1 [ 500] 500 L/min(PFMB7102) [F 1][oU1] [1000] 1000 L/min(PFMB7202) 28 [ 25] 25 L/min(PFMB7501) [H_1] OUT1 [ 50] 50 L/min(PFMB7102) [100] 100 L/min(PFMB7202) [CoL] OUT1 [SoG] ONOFF [oU2] OUT2 2 [HYS] [2ot] OUT2 2 [2_P] [ 250] 250 L/min(PFMB7501) 2 [P_2] OUT2 [ 500] 500 L/min(PFMB7102

*1: To use the power of the device, the total load current must be 500 mA or less.

*1: To use the power of the device, the total load current must be 500 mA or less.

Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at

AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 AMF150 Model Note) 500 1000 2000 3500 6000 12000 200 Rated flow (l/min (ANR)) Port size (Nominal size B) , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (KB) D-A7/A8 Auto switch KA A + Stroke B + Stroke W L S EA EB EC M J 2 x 2-OA 2 x 2-RA Both ends tapped style (CQMA) (mm) Without auto switch With auto switch Stroke range (mm) Bore size (mm) P P EA EB EC B F Q A B F Q A TN TF NN NN TN TF 5 5.5 11.5 M5 x 0.8 M5 x 0.8 40 23 32 10 to 50 50 33

Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at

Note 4) When ordering the body only, select the symbol from to respectively. 2020 PVQ Specifications VEF VEP Rated pressure range Display/Set pressure range Withstand pressure Display/Minimum setting unit Applicable fluid Power supply voltage Current consumption Switch output 0 to 1 MPa 0.1 to 1 MPa 1.5 MPa 0.01 MPa (Air, Non-corrosive gas, Non-flammable gas) 12 to 24 VDC 10%, Ripple (p-p

Note 4) When ordering the body only, select the symbol from to respectively. 2020 ITVX Specifications PVQ Rated pressure range Display/Set pressure range Withstand pressure Display/Minimum setting unit Applicable fluid Power supply voltage Current consumption Switch output 0 to 1 MPa 0.1 to 1 MPa 1.5 MPa 0.01 MPa (Air, Non-corrosive gas, Non-flammable gas) 12 to 24 VDC 10%, Ripple (p-p)

(The SI unit is provided for use in Japan.) *9 p: For pipe thread type: NPT only *10 : Select with options: E1, E2, E3, E4. 79 A AR20-B to AR60-B Regulator AR20K-B to AR60K-B Regulator with Backflow Function Made to Order Please contact SMC for detailed dimensions, specifications and lead times.

P tight screw (4 x 14) , 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc. P tight screw (4 x 14) , 2 pcs. (3) Intermediate support bracket EX600-ZMB1for direct mounting Enclosed parts: Round head screw (M4 x 5) , 2 pcs.

L X P Table displacement (m) Table displacement (m) LXPB-200 LXPB-200 1500 1500 LXPB-175 LXPB-175 1000 1000 LXPB-150 LXPB-150 LXPB-125 LXPB-125 LXPB-100 LXPB-100 500 500 LXPB-75 LXPB-75 LXPB-50 LXPB-50 0 Weight (kg) 0 Weight (kg) 1 2 3 4 5 6 1 2 3 4 5 6 Displacement at the section indicated by the arrow when a load is applied to this section with the slide table fully extended.

Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.

Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.