Vacuum Switch Diaphragm Style Series ZSM1-115/121 Specifications ZSE ISE PSE ZSM1-115 ZSM1-121 Model Solid state Contact (Reed switch) Switch specifications Z I SE3 Air/Inert gas Fluid 0.5 MPa Max. operating pressure PS 27 to 80 kPa Regulating pressure range Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
1 Adsorption Confirmation Switch Series ZSP1 ZSE ISE PSE For General Pneumatics Z I SE3 PS Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 IF Data Can be integrated with ZX ejector system.
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [dm3] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Power supply Thermometer Pressure switch Control circuit Solenoid valve Pressure control equipment
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [dm3] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Power supply Thermometer Pressure switch Control circuit Solenoid valve Pressure control equipment
Indicator Unit (LED) Descriptions and Functions SI unit (DeviceNet) SI unit (PROFIBUS-DP) Input block 1 3 5 7 PWR 0 2 4 6 TM TM PWR(V) RUN PWR(V) MOD/NET PWR ADDRESS 1 H L 0 SETTINGS DIA BF FB FB PS PS Description Description Function Function Description Function PWR(V) ON when solenoid valve power supply is turned ON. ON when sensor power is turned ON.
Pressure setting of 7 Ps|{0.51kgflcmr} (lT1 000 only), 50 PSI{3.51 kg7cm,}, '|0O PSI{7.1kg cml are available in addition lo the existing pressure setting ol 15 PSIII.oftgtcmr), 72 PSI{5.1kg't cm'?), and l3O Ps|{9.2kgflqrr}. . The subdivided pressure range rmproves pfessure accuracy. . The change in zero span cor rol range improves the controlling ope.ation.
]ucoro-cs -l,r'c6zo.cTfm-r'rcozs+s' rircora-ns l,tcolo-cs I mcoso-es [tco63-Ps MGo8o'Ps lMGoloGP 1gq so,0111 31!
|.tE: 21" vscuum @ PS|G (20 Kgvcnf) P-..cr rbnlr: 2e v@m 3OO Ps|G (2O Kgt/.m1 b.bF: Pon io po.r {inrdr'6D nor ro qcd 0,007 d$rc i6.r por minutg d 1@ PslG (6.9 Ba.l. MOUNTING: Intended for suFplate or manifold mounting. Elct.icalwires exit from base o( the valve into manifold or individual sub-plale junclion boxes for simplification & proteclion of wi.ing connections.
NC1A: NC1A, Option: Single Rod, Bore: 325, PS: PS, Special Options: XB5B6 (Oversized Rod w/High Temperature)
NC1A: NC1A, Option: Single Rod, Bore: 250, PS: PS, Special Options: XB5B6 (Oversized Rod w/High Temperature)
NC1A: NC1A, Option: Single Rod, Bore: 200, PS: PS, Special Options: XB5B6 (Oversized Rod w/High Temperature)
NC1A: NC1A, Option: Single Rod, Bore: 400, PS: PS, Special Options: XB6 (High Temperature)
PS-Thermistor Assy. 300.00000 lb. 729.
Stations: 06, System, Port Combinations: Vacuum Pump System, Common PV: ø8, Common PS: ø6, Metric Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: D [w/Common Release Pressure Supply (PD) Port], Manifold Assembly, Delivery Condition: Delivered as Individual Parts, not Assembled
Stations: 03, System, Port Combinations: Vacuum Pump System, Common PV: ø8, Common PS: ø6, Metric Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: D [w/Common Release Pressure Supply (PD) Port], Manifold Assembly, Delivery Condition: Delivered as Individual Parts, not Assembled
Stations: 10, System, Port Combinations: Vacuum Pump System, Common PV: ø8, Common PS: ø6, Metric Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: D [w/Common Release Pressure Supply (PD) Port], Manifold Assembly, Delivery Condition: Delivered as Individual Parts, not Assembled
Stations: 06, System, Port Combinations: Vacuum Pump System, Common PV: ø8, Common PS: ø6, Metric Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: Individual Wiring Specification, Option: w/DIN Rail Mounting Bracket, Manifold Assembly, Delivery Condition: -
Stations: 10, System, Port Combinations: Vacuum Pump System, Common PV: ø8, Common PS: ø6, Metric Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: D [w/Common Release Pressure Supply (PD) Port], Manifold Assembly, Delivery Condition: -
Stations: 03, System, Port Combinations: Vacuum Pump System, Common PV: ø8, Common PS: ø6, Metric Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: D [w/Common Release Pressure Supply (PD) Port], Manifold Assembly, Delivery Condition: -
Stations: 06, System, Port Combinations: Vacuum Pump System, Common PV: ø8, Common PS: ø6, Metric Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: D [w/Common Release Pressure Supply (PD) Port], Manifold Assembly, Delivery Condition: -