SMC Corporation of America
Elite Part Number Search
Search Results "HRR030-AN-20-U"

mm Lead 150 Slide screw 20 mm Lead 500 10 mm Lead Ball screw Horizontal specification Maximum speed 1000 600 500 930 740 20 mm Lead 100W mm/s 500 Slide screw 20 mm Lead 180 10 mm Lead Ball screw 100W Nm Rated thrust 90 20 mm Lead 50 Slide screw 20 mm Lead Rolled 0.05 Repeatable positioning accuracy Ball screw Ground 0.02 mm 0.1 Rolled Slide screw Motor output Horizontal specification

<18> 20 20 GA 19 17 17 13 B1 6 5.5 5.5 5 K 44 35.5 29 24 NA 9 7 7 7 RA 26 20 16.5 14 C 130 121 119 114 ZZ 14 10 8 6 KA 78 79 77 77 S 16 12 10 8 D 25 18 14 12 E 2 2 2 2 F 40 32 25 20 30 22 22 18 23 0<23> 0 0 10 0 0 0 M5 x 0.8 depth 7.5 M5 x 0.8 depth 8 M14 x 1.5 M6 x 1 depth 12 12 12 1/4 1/4 3/8 1/2 58 58 27 27 32 41 14<12> 14<12> 10 10 10 10 23 20 20 20 11 11 58 72 20<17> 20<17> 16 16 71

Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Standard type Nil PNote 1) Axial piping type Note 1) The combination of axial piping type and both ends adjusters or retraction end adjusteris not

Content of diagnosis 0 There is an error in unit 0. 1 There is an error in unit 1. 2 There is an error in unit 2. 3 There is an error in unit 3. 4 There is an error in unit 4. 5 There is an error in unit 5. 6 There is an error in unit 6. 7 There is an error in unit 7. 8 There is an error in unit 8. 9 There is an error in unit 9. 10 Reserved 11 Reserved 12 Reserved 13 Reserved 14 Reserved

Operation stop Combination Symbol: D1 Combination Symbol: D4 An N.C. solenoid valve is used for the vacuum release valve. An external supply valve must be provided. An external valve must be provided to serve as the supply valve. An air operated N.C. valve is used for the vacuum release valve.

There may be the case it will vary substantially depending on an ambient environment. (n 2) 2 20 + 55 D-A59W 30 (n = 2, 4, 6, 8 ) Note 1) (n 2) 2 20 + 40 D-Z7/Z80 20 (n = 2, 4, 6, 8 ) Note 1) D-A5/A6/A59W cannot be mounted to 40, 50. Note 1) When n is an odd number, an even number that is one larger than this odd number is used for the calculation.

Low Profile Air Gripper Series MHF2 Height is approximately 1/3 the size of an equivalent Series MHZ2. (mm) MHZ2-20D3 42 Height Bore size 19 25 33 41 8 12 16 20 MHF2-12D 72.8 52 25 50 The low profile design saves space and reduces bending moments.

Install an air filter near this product on the supply side. Select a filtration degree of 5m or less. 2. Compressed air containing a large amount of drainage can cause malfunction of this product and other pneumatic equipment. As a countermeasure, install an after-cooler, air dryer or water separator, etc. 3.

6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/M9mW(V)/M9mA(V) 3 3 4.5 4.5 Values which include hysteresis are for guideline purposes only, they are not a

Dimensions (mm) Electrical entry Z J E H C G A B D Model Grommet Conduit DIN terminal Conduit terminal Y N X W V U T S R Q VV2CL2 56 34.5 4.5 17.3 24.5 38 49 20 28 77 66 99 41.5 58 46 43.5 44 45.5 22 VV2CL3 66 38.5 5.5 19.3 28.5 42 57 25.5 30 86.5 68 101 51 60 48 53 45.5 55 24 VV2CL4 74 41.5 5.5 20.8 28.5 42 57 25.5 30 94 70 103 58.5 62 50 60.5 47.5 62.5 26 17-2-37

D2012-10-9 9 Series MHY2 Construction Closed condition Size 10 Size 16 Size 20, 25 r o !8 e w !7 t r o !8 e w @0 !7 t r o !8 e w @0 !7 t !5 !5 !5 !6 !6 !0 u !2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !4 Open condition Component Parts Note Note No. q Description Material No. Description Material Bushing B !

D2012-10-9 9 Series MHY2 Construction Closed condition Size 10 Size 16 Size 20, 25 r o !8 e w !7 t r o !8 e w @0 !7 t r o !8 e w @0 !7 t !5 !5 !5 !6 !6 !0 u !2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !

Trigger input GND 8 4 Input/Output circuit 20 IZN10E Series Made to Order 1 This product is an individually applicable product. For details about the delivery time and price, please consult with SMC representative.

VV4Z1 05 20 1 VP VG Option Thread type 02 2 stations A port F: With foot bracket VP Nil Rc G NPT 00F 20 20 stations R port 00N S070 Rc NPTF 00T VQ P port Rc Bracket is not mounted.

(mm) A 158 B 70 C 50 D 20 E F 24.5 G 60.5 H 5 I 70 J 60 K 5.5 L 72 M 37 N 2 O 30 P Rc1/4 Q R 59 Sa Sb T 500 U 250 V 310 Model ZH30--X185 ZH40--X185 28.5 146.5 M4 x 0.7 10 203 90 64 25 27.2 33.5 196.8 74.5 6 90 78 6.5 92 47 2.3 42 Rc3/8 76 500 250 310 Note 1) This thread portion is intended to adjust the product characteristics.

2 x 3.4 33 IZH 30 30 52 46 44 26 17 11 40 5 8 x 3.4 20 26 12 2 x Hexagon socket head cap screw M3 x 6 (Accessory) Internal mounting Pivot mounting 21 33 (Mounting angle adjustable range) (90) 61 61 30 Pivoting bracket/IZN10-B2 20 3.4 56 64 28 20 (Mounting angle adjustablerange) 20 9.5 9 90 24 3.4 4 14 40 2 x Hexagon socket head cap screw M3 x 16 59 11 (Accessory) 18 457 IZN10 Series Dimensions

Construction VHS20/30 VHS40/40-06/50 y i u w w t t r q IN OUT OUT IN q e o EXH. EXH. VM Component Parts No.

20 20 20 20 20 20 20 9.5 9.5 9.5 11.5 D-F7, F7V D-J79, J79C D-F7W, F7WV D-J79W D-F7BAL, F7BAVL D-F7NTL, F79F D-F7W D-J79W D-F7BAL D-F79F D-F9BAL 6 6 6 6.5 Number of auto switch D-F7LF D-A9 D-F9 D-A79W 7.5 7.5 8 D-F7LF 7.5 D-F9, F9V D-F9W, F9WV D-F9BAL 1 pc. 2 pcs. 20 20 20 20 25 25 20 20 5.5 5.5 5.5 6.5 The operating ranges are provided as guidelines including hystereses and are not guaranteed

Standard Stroke Model Standard stroke (mm) 10, 20, 30, 40, 50 MXQ6 10, 20, 30, 40, 50, 75 MXQ8 10, 20, 30, 40, 50, 75, 100 MXQ12 10, 20, 30, 40, 50, 75, 100, 125 MXQ16 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ20 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ25 8-5-9 10 Series MXQ Theoretical Output IN OUT The dual rod ensures an output twice that of existing cylinders.