Hs A B A B Proper auto switch mounting position (mm) D-A7H, A80H, A73C, A80C D-F7, F7V, F79F, J79 D-J79C, F7W, F7WV D-J79W, F7BAL, F7BAVL D-A7 D-A80 D-F7NTL D-A79W D-F7LF Bore size (mm) B B A A B A B A B A 32 11 10 50 51 3 43 6 46 5.5 45.5 40 13.5 12.5 56.5 57.5 5.5 49.5 8.5 52.5 8 52 50 18 19 61.5 60.5 11 53.5 14 56.5 13.5 56 63 22 21 67 66 14 59 17 62 16.5 61.5 Auto switch mounting height
Switch operating range Stroke (mm) 20 41 29 47 35 Type 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B MXP10 Auto switch MXP12 3 Screwdriver (Grip diameter 5 to 6mm) MXP16 2 Color indication solid state switch D-F9BW(V), D-F9NW(V), D-F9PW(V) mm Switch operating range Stroke (mm) 20 42 28 48 34 Type 25 47.5 33.5 30 56 46 10 32 18 15 37.5 23.5 A B A B A B MXP10 MXP12
VN LVC LVA LVH Variations LVD LVQ Valve Material Base, Body Seal Aluminum NBR, FKM, EPDM LQ Common SUP Individual SUP Common SUP Individual SUP Port A Port A Normally closed (N. C.) LVN Port P TI/ TIL Port P Port P PA Port A PAX Port A Port A PB Normally open (N. O.)
Piston A Piston A C A A Piston B Piston B First-stage extension First-stage retraction Piston A Piston A B A C A C Piston B Piston B Second-stage extension Second-stage retraction 10-10-4 5 3 Position Cylinder Series RZQ Weight Weight Table Unit: kg Cylinder stroke Bore size (mm) 25-5 50-5 75-5 100-5 125-5 150-5 175-5 200-5 250-5 300-5 32 40 50 63 0.81 0.88 0.94 1.01 1.07 1.13 1.20 1.26 1.39
Auto Switch Proper Mounting Position (Detection at Stroke End) A B Proper Mounting Position (mm) Bore size A B 40 63 100 32.5 0 16 0 27.5 0 Note) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.
(Plug: M-5P) 49 46 38 5 22 12 19 4 40 25 Y Y 5.5 Operating port M5 ~0.8 24 84 Operation direction B (Plug: M-5P) Operation direction B A 7 6.5 13 10 10 13 A 14.8 30 7 24 A 15.8 Z Cross section AA (scale 50%) (N-1) x H G H 6 depth 4.5 5H9 +0.03 N-M4 x 0.7 thread depth 8 0 Bottom through hole 3.3 5H9 +0.03depth 4.5 0 F E Model J N H G F E Z MXW8-25 64 3 32 47 48 55 157 MXW8-50 71 4 30 46 76
As a rule, it should be turned about 90 beyond the point at which tightening can be felt. Auto Switch Mounting Bracket Part No. Auto switch part no. D-M9(V) D-M9W(V) D-M9A(V) Auto switch mounting bracket part no.
Avoid to using 2 or more end lock cylinders at same time to perform a single task because binding may occur and one of the cylinders end lock may not release. y Use a speed controller as meter-out. Meter-in control may not allow lock to release. Locking style Turn 90 to counterclockwise pushing M/O button. Lock is released when G on cap and H OFF mark on M/O button correspond.
9 i *1 *1 C95K32 A A-A A !2 !1 @4 Component Parts Description Aluminum die-casted Aluminum die-casted Aluminum alloy Stainless steel Aluminum alloy Rolled steel Rolled steel Oil impregnated sintered alloy Steel Steel for spring Carbon Steel Steel Steel Material No. !4 !5 !6 !7 !8 !
Reliable outlet side A firm seal is secured through a special configuration combining a pressure clamp from an O-ring around the inner perimeter of the case with support from the cover, and there is no resistance when the cover is installed and removed. Large drain exhaust port The large M24 drain exhaust port assures rapid drainage.
Contents Bore size (mm) MB40-PS MB50-PS MB63-PS 40 50 63 80 100 MB40-PS MB50-PS MB63-PS MB80-PS MB100-PS #9 $0 41 Piston seal NBR Rod seal A NBR Set of left nos. #9, $0, $3, $5 Rod seal B NBR MB80-PS 42 $3 44 $5 46 Release piston seal NBR MB100-PS 41, 42, 44 and 46 to 49 are non-replaceable parts, so they are not included in the seal kit.
Cylinder Speed Chart Use as a guide for selection. Please confirm the actual conditions with P/A Sizing Program.
Dont use a wrench on push-to-connect end. 2 2 Cut tubing square with a clean 90 edge Dont use excessive tube angle cut which can lead to leakage or breaking. 90 90 3 3 Use SMC Tube Cutters Dont use dikes, a knife, a saw or a dull tool to cut the tubing.
4 SMC 37.6 53.6 B 2 18.5 12 12 e d i s U e d i s D Stations 1 2 3 4 5 6 7 8 n One-touch fitting [3(R), 1(P) port] Applicable tubing O.D.: 10 10 Lead wire length: L0, 0.6 m L1, 1.5 m L2, 3.0 m For top ported R 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 62.1 41.7 25.7 39.4 (58) 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 20.9 P 1 P=17.5 48.8 30 7.5 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4 :
Flow Characteristics Series Flow characteristics C [dm3/(sbar)] b Cv 0.29 0.90 1.4 2.5 0.28 0.37 0.28 0.29 1.1 2.8 4.5 10 SY3000 SY5000 SY7000 SY9000 Cover (stainless steel) Cylinder Speed Chart Use as a guide for selection. Please confirm the actual conditions with P/A Sizing Program.
-9200-www.stevenengineering.com V: Female thread for bracket mounting Same as back side 8 locations Main port Bracket U: Long hole for mounting 4 positions Flow indicator for 2 port valve Dimensions (mm) Model Main port 2 Port 2-Rc 2-Rc Pilot port A B C D E F G H I 3 Port 3-Rc 3-Rc 3 8 3 8 Rc 1 8 VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A A B A B A B A B 60 80 100 115 235.5 265 300 319.5 60
Use a dedicated hose nipple. On the panel mounting style, use the CJ5H-4 or CJ-5H-6, a dedicated hose nipple (with a fixed orifice) that is provided. If a different fitting must be used due to unavoidable circumstances, make sure to install a speed controller and use it by adjusting it to 500 mm/s or less.
Use a dedicated hose nipple. On the panel mounting style, use the CJ5H-4 or CJ-5H-6, a dedicated hose nipple (with a fixed orifice) that is provided. If a different fitting must be used due to unavoidable circumstances, make sure to install a speed controller and use it by adjusting it to 500 mm/s or less.
M B This is the amount of deflection on a dial gauge when the guide block travels a full stroke with the body secured on a reference base surface.