. : Time it takes for ozone to generate cracks (h) C: Ozone concentration (ppm) n: Constant that varies depending on the rubber material Take the logarithm and rearrange the above equation as follows: log = K n logC K: Constant YU.S Zuev and S.I.
15 D-M9mA n 15 + 40 (n 2) 2 ( n =2, 4, 6, 8) Note) 2 (Different surfaces, Same surface), 1 15 D-M9mAV n 15 + 30 (n 2) 2 (n = 2, 4, 6, 8) Note) Note) When n is an odd number, an even number that is one larger than this odd number is used for the calculation. 6 JMB Series Operating Range [mm] Auto switch model Bore size 32 40 45 50 56 63 67 80 85 100 D-M9/M9V D-M9W/M9WV D-M9A/M9AV 3.5 4
Setting range: 156 k/625 k/2.5 M/5 M/10 Mbps (3) Station number setting Specifies a station number to assign to the compact wireless Base (Remote device station) on CC-Link.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, THERMO CHILLER, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 489.42621 lb
Standard Strokes Bore size (mm) 20 32 40 50 63 80 100 Standard strokes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Made to Order 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Page 34 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 JIS symbol 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30
40 0.4MPa 0.4MPa F 0.3MPa 0.3MPa 20 20 0.2MPa 0.2MPa 0 0 10 10 20 20 30 30 40 40 Gripping point L mm Gripping point L mm MHS2-25D MHS2-25D 100 100 F Internal gripping Pressure 0.6MPa Pressure 0.6MPa 80 80 Gripping force N Gripping force N 0.5MPa 0.5MPa 60 60 Note: 1N = 0.2248lbf 1in = 25.4mm 1MPa = 145psi 0.4MPa 0.4MPa 40 40 0.3MPa 0.3MPa 0.2MPa 0.2MPa 20 20 0 0 10 10 20 20 30 30 40 40 Gripping
At least 40 mm of maintenance space is necessary for removing the bowl. Bolt Flange drop prevention stopper Stainless steel bowl Minimum maintenance space 40 mm It is possible to remove the bolts from the same direction (front). An element service indicator is fitted as standard. The new red ring is larger than the existing indicator, which improves visibility.
H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 144.5 55 125.5 52 42 26 29 4.5 14 24.3 72.5 2.3 80.5 25 75 34 80 84.5 124 135.5 151.5 137 153 156 172 60.5 73 1 80 90 62 72 50 60 31 36 35 40 5.5 6.5 17.5 20 28.3 33.3 84 100 2.3 2.3 92 108 30 35 84 90 43 49 89 95 93.5 99.5 Port
-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.
-X 545 C(L)KU32 Series Auto Switch Mounting 2 Auto Switch Mounting Height Applicable cylinder: C(L)KU32-X2321 C(L)KU32-X2322 D-P3DWA 44.5 23.5 D-M9V D-M9WV 40 35 D-A7 40 22 546 Auto Switch Mounting C(L)KU32 Series Auto Switch Mounting Bracket Part No.
(AR20(K)/25(K)/30(K)/40(K)) AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR20(K)/25(K)/30(K)/40(K) Hook spanner Nominal Tightening torque 2.0 0.2 Nm 2.5 0.2 Nm 3.5 0.3 Nm 4.0 0.4 Nm AR20(K) AR25(K) AR30(K) AR40(K) AR20(K) AR25(K) AR30(K) AR40(K) 34/38 40/42 52/55 52/55 Assembly (Bracket assembly) 1) Mount the bracket to the product.
(AR20(K)/25(K)/30(K)/40(K)) AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR20(K)/25(K)/30(K)/40(K) Hook spanner Nominal Tightening torque 2.0 0.2 Nm 2.5 0.2 Nm 3.5 0.3 Nm 4.0 0.4 Nm AR20(K) AR25(K) AR30(K) AR40(K) AR20(K) AR25(K) AR30(K) AR40(K) 34/38 40/42 52/55 52/55 Assembly (Bracket assembly) 1) Mount the bracket to the product.
B L A C K L E A D W I R E Connects with minus (-) side of the direct current to actuate the switch.
LVC DIN terminal: D Conduit terminal: T Cable 6 to 12 LVA F S Q 27.5 34 F (Q) LVH LVD LVQ LQ R C U 25 LVN C (44) R E R TI/ TIL G1/2 E PA G1/2 A H D (S) B B A H D 2-P Port size 2-P Port size PAX 2-M Thread depth N 2-M Thread depth N PB L L K K N.C.
SI unit of the SDTC or SDTD specification to an input block or valve.
12.5 145 Rubber cushion: C76RBY Without magnet, Built-in magnet Bore Stroke B S + Stroke ZZ + Stroke (mm) AM 20 24 C 12 14 D 37.5 46.5 EE G 1/8 G 1/4 F 42.4 52.4 FF M6 x 1 depth 11 M8 x 1.25 depth 14 FX 30 36 G1 22 27 H 36 40 K 10 12 KK M10 x 1.5 M12 x 1.75 N1 29 38 N2 17 22 NB 34.5 42.5 NDh8 S 80 105 SW 17 19 WH 16 16 ZZ 116 145 Bore 26 0 0.033 32 40 32 0 0.039 6-10-40 41 Series C76R Air
Stroke B C95 CP95 NCM NCA D-X 20Data S + Stroke ZZ + Stroke (mm) AM 20 24 C 12 14 D 37.5 46.5 EE G 1/8 G 1/4 F 42.4 52.4 FF M6 x 1 depht 11 FX 30 36 G1 22 27 G2 9 12 H 36 40 K 10 12 KK M10 x 1.5 M12 x 1.75 N1 29 38 N2 17 22 NB 34.5 42.5 NDh8 S 80 105 SW 17 19 WH 16 16 ZZ 116 145 Bore 26 0 0.033 32 40 32 0 0.039 M8 x 1.25 depht 14 6-10-39 40 Series C76R Dimensions [First angle projection]
Bore size Series CJ2 Pressure 0.5 MPa Load ratio 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm Series MB, CA Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load ratio 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 125 140 160 180 200 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQC1000
67 k 1 0 to 10V Note 2) Not conforming to ISO1179-1. 24 V 2 4 to 20 mA 120 3 0 to 20 mA 5 1 to 5 V 67 k 10 k 6 0 to 10 V 12 V 7 4 to 20 mA 120 8 0 to 20 mA Symbol Symbol B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) Body size Port size Rc Option Applicable pilot valve (4) Mounting Port 1(P), 2(A) Port 3(R) 00 M5 00 M5 01 00 01 02 00 02 03 04 M5 01 02 02 03 04 04 06 10 10 12 14 20