Model Z ARP20(K) H J H J M N Q R S T U V W Y 27.8 1021 1021 1021 44 40 69 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 ARP30(K) 27.8 44 41 70 41 40 44 6.5 8 53 2.3 31 38.5 19 7 ARP40(K) 27.8 44 45 74 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 Note 1) The total length of B direction is the length when the filter regulator knob is unlocked.
D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.
Power dissipation (W): For AC , W = V/A cos. For DC, W = V/A. (Note) cos shows power factor. cos = 0.6 2. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. 3.
g n n k k ra oc c a o t r cl cl en nt er er e tm e m nt nt is us u t u w C 0 us o 90 k o c lo o C l dj C C 19 dj se c Cl 1 A k A A wi e w oc ge dj k A is oc k ng dj u wi e Cl an st us se ro ra m r ta t ot m r d at ti n e n io on e n e on nt e nt tio nd r r a a ti n n g ta e 5 9 g ta e 9 ro 5 ro m m u im u im ax M ax M Note) The drawing shows the rotation range of the positioning pin hole
DC (17 mA), 0.95 W DC (40 mA) Note 3) Power consumption (Current) 12 VDC 0.4 W DC (34 mA), 0.95 W DC (80 mA) Note 3) Note 1) Use dry air to prevent condensation when operating at low temperatures.
-W-20/40/46. 8-11 8.4 Cooling capacity . 8-12 HRS Series HRX-OM-S004 Contents 8.4.1 HRS100-A-20/40/46. 8-12 8.4.2 HRS150-A-20/40/46. 8-12 8.4.3 HRS100-W-20/40/46. 8-13 8.4.4 HRS150-W-20/40/46. 8-13 8.5 Pump capacity . 8-14 8.5.1 HRS100/150-A/W-20/40/46. 8-14 8.6 Types of Hazard Labels (HRS--40/46-) . 8-15 8.6.1 Positions of danger warning label . 8-16 8.7 Standards . 8-17 8.8 Sample DoC.
output: 1 to 5 V Output impedance: 1 k F: Analog output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 Max. applied voltage: 28 V, Max. load current: 80 mA, Internal voltage drop: 1 V or less C: Analog output: 1 to 5 V Output impedance: 1 k D: Analog output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 PNP (1 output) + External input type PFMC7--HNPN (1 output
force W x (kg) Lo: Distance from mounting surface to load center of gravity (cm) : Friction coefficient up to 45 1 up to 60 0.9 up to 75 0.8 up to 90 0.7 Angle k 32 Angle coefficient (k) : k = [to 45 (= )] = 1, [to 60] = 0.9, [to 75] = 0.8, [to 90] = 0.7 Lo: Distance from mounting surface to load center of gravity (cm) 40 6 10 15 20 Bore size (mm) 2.72 1.6 + Lo 5.55 1.95 + Lo 15.96 2.4
Apparent power AC Inrush VNC VNC Holding 1.8 W (without light), 2 W (with light) 4 W (without light), 4.2 W (with light) Non-locking push type, Other (Option) Non-locking push type Power consumption VNH DC Graph (1) VNC2 Pilot Pressure (N.O. type) 0.5 0.6 0.7 Pilot pressure should be within the range of A against the operating pressure.
2-M Thread depth 6 2-M Thread depth 6 K VN LVC LVA LVH DIN terminal: D Conduit terminal: T LVD F F (Q) Q S 34 LVQ D LQ LVN U 25 R C 44 TI/ TIL C R G1/2 PA E E G1/2 PAX B B 2-P Port size A A D 2-P Port size (S) PB Port size G1/2 Compatible heavy-duty cord Cable O.D. 6 to 12 L L K 2-M Thread depth 6 K 2-M Thread depth 6 (mm) Electrical entry P Port size B Model A C D E F K L M Grommet: G Conduit
Tank capacity (l) Tc [s] = L W Obtain the tank capacity V. Select tank from table below.
W 32 40 50 63 80 100 22 30 35 35 40 40 27 125 to 1000 50 223 97 15 17 120 1/2 38 M27 X 2.0 13 M12 X 1.75 6 20 19 27 60 32 110 136 54 46 52 65 75 95 114 32.5 38 46.5 56.5 72 89 12 16 20 20 25 30 30 35 40 45 45 55 13 13 14 14 20 20 13 14 15.5 16.5 19 19 47 51 58 58 72 72 16 16 16 16 16 16 4 4 5 5 5 5 M6 X 1 M6 X 1 M8 X 1.25 M8 X 1.25 M10 X 1.5 M10 X 1.5 6 6 7 7 10 10 M10 X 1.25 M14 X 1.5 M18
mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W704 0.5 4 PF3W720 2 16 PF3W740 5 40 PF3W711 10 100 PF3W721 30 250 -79No.PF-OMM0004-D / A B C D 0.6 V 1 V 5 V 5.4 V 2.4 mA 4 mA 20 mA 21.6 mA -80No.PF-OMM0004-D PF3W704/720/740/711 A AA B D E F G H J K L N P PF3W704 3/8 70 50 30 60 40.6 15.2 24 14 35 26 18 13.6 2.7 14 PF3W720
mA (PF3W511) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W521-12/14) A B C 1 V 1.8 V 5 V 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C 1 V 1.48 V 5 V 4 mA 5.92 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521-12/14 50 250 PF3W521-U30 30 250 () A B C D 0.6 V 1 V 5 V 5.4 V -40No.PF-OMN0009CN-F PF3W504/520/540/511 2X A AA B DD E F G H J K L N P PF3W504 3/8 70 50
Balance adjustment trimmer 4 x M4 x 0.7 depth 5 14 19 20 (For mounting, opposite side: Same) 13 17 7 Connection cable IZS31-CF-X210 14.9 16 20 20 52 (Cable length: Refer to the above table.) 65 8P modular jack (Plug for sensor cable) Maintenance detection level selection switch 15 100 4 x M4 x 0.7 depth 5 20 900 Connection cable length L (For mounting, opposite side: Same) 7 16 26 58 80x2
Flat finger [3] 4 x MM thread depth L Thread for mounting attachment K J A A D G B D B K J F C S W O (mm) Weight (g) F G Open Closed 2 2.5 3 4 L MM J K D C B Model A W MHZ2-10D3 1), 2) 11221122112211220 -0.05 0 -0.05 0 -0.05 0 -0.05 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 +0.025 0 +0.025 0 +0.025 0 +0.030 0 +2.2 0 +2.2 0 +2.3 0 +2.5 0 60 125 250 450 5 6 8 10 M2.5 x 0.45 M3 x 0.5 M4 x 0.7
is at least 10 to 20 times the work piece weight.
20 11 22 14 60 60 129 MB-SIO . 100 11 4 \20 90 15 158 132 \84 26 13.5 24 17 75 100 '29 25 +008001 (mm) [~ "r.
MSQ Angle adjustment Range Figure 5 MSZ MSZ CRQ2X MSQX ad a ge ju Cl lt MRQ an st bo oc t r m nd en g k en tm wi in e us 10 10 se t r st on dj a ju an r on ti ot ad iti ta os ge at p ro er y nt io e b C e b n y is e ge n ad w d k an c ju lo t r C st in en g m bo st lt ju b ad M 0 ax 19 im e u ng m ra ro n ta tio Center position adjustment Table 2 R: Clockwise adjustment L: Counterclockwise
2 u r e q w No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !8 !