Series VXZ22/23 Construction N.C. N.O.

38 38 46.5 18.3 (18.8) 6 12.8 29.4 18.5 59 40.9 55 8 15.2 31.9 20.5 61 43.4 57 19.8 45.8 40.8 R 3/8 19 23 40.6 35.6 10 18.5 33.6 45.1 23 63 59 (20.9) (46.9) (41.9) 12 20.9 34.8 46.3 24 65 61 10 18.5 35.6 49.9 23 107 100 24.5 57.2 49.7 R 1/2 24 28.6 49.9 42.4 12 21.7 38.2 24 109 102 52.5 (25.4) (58.1) (50.6) Note 1) Reference dimensions Note 2) Reference dimension for threads after installation

38 38 46.5 18.3 (18.8) 6 12.8 29.4 18.5 59 40.9 55 8 15.2 31.9 20.5 61 43.4 57 19.8 45.8 40.8 R 3/8 19 23 40.6 35.6 10 18.5 33.6 45.1 23 63 59 (20.9) (46.9) (41.9) 12 20.9 34.8 46.3 24 65 61 10 18.5 35.6 49.9 23 107 100 24.5 57.2 49.7 R 1/2 24 28.6 49.9 42.4 12 21.7 38.2 24 109 102 52.5 (25.4) (58.1) (50.6) Note 1) Reference dimensions Note 2) Reference dimension for threads after installation

When mounting on the bottom of the cylinder, the guide rod protrudes from the bottom at the retraction stroke end. Therefore, drill holes for the hexagon socket bolts used for mounting purposes, and relief holes for the guide rods. Moreover, in applications where impact occurs from a stopper, etc., the mounting bolts should be inserted to a depth of 2 d or more.

Auto switch 1 Auto switch 1 Blue Blue Brown Brown Auto switch 2 Auto switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 kW = 6 V Example: Load impedance is 3 kW. Leakage current from auto switch is 1 mA.

In addition, when valve is used at low temperature, low temperature oil should be used. The used of turbine oil at temperatures lower than 0C leads to increased viscosity and may cause the valve to malfunction.

Swivel elbow P. 106 L Use to pipe at right angle to female thread portion. Swiveled at any direction. Swivel long elbow P. 106 LL Use to pipe at right angle to female thread portion. Swiveled at any direction. Solid piece moves fittings up from workpiece. 103 Series H, DL, L, LL Self-align Fittings Male connector: H Applicable tube O.D.

the body side, while in case of A2 and B2, at the manifold side.

Change of the return point at the time of power failure At the time of power failure, circuits A to C return the piston to the retraction end. To return the piston to the intermediate point at the time of power failure, add changes to the 3 port valve on the cylinder rear side so that it will be normally open.

at 40 mA) Current leakage 100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.

For details, refer to pages 7-9-23 and 7-9-21. 7-4-45

The graphs below show the response time when the workpiece is approached at 90% distance and 0% distance (close contact). (*: The switch point is 100% distance.) (Example: When the switch point is set to 0.1 mm, the response time when the workpiece is at 0.09 mm and 0 mm are measured.)

/SO2+ 23 1 Lock interlock signal 2 Used for general-purpose output. Note: Set the parameter to allocate a function.

39 2.3 Pg.7 1 20.5 P = 19 13.5 5 1.5 20.5 25 30 53.5 Approx. 300 (lead wire length) L2 L1 31 10.5 8 39 23 49.5 1.5 10.5 49.5 4-M3 x 0.5 depth 6 (bracket mounting screws) 4-4.5 (bracket mounting holes) 7 7 5 L3 P = 19 16 nRc(PT) 1/8 (port A) 23 8 19.5 L: Dimension table n: Stations n L L1 L2 L3 1 37 27 13 2 56 46 32 3 75 65 51 4 94 84 70 5 113 103 89 6 132 122 108 7 151 141 127 8 170 160

10mA load current) 0.8mA or less at 24VDC Leakage current 100A or less at 24VDC Indicator light Red LED lights when ON Lead wireOil proof heavy duty vinyl cord, 3.4, 0.15mm2, 3 cores (brown, black, blue), 2 cores (brown, blue), 0.5m Note 1) Refer to page 10 for solid state switch common specifications.

D-M9/M9W D-M9A/A9 Note 1) The mounting position should be referred for reference only for the auto switch mounting position at the stroke end detection. Adjust the auto switch after confirming the operation to set actually. Note 2) The auto switch mounting position is temporarily set at the time of shipping from our factory.

MK/MK2 RSQ/RSG 0.2 l53 RSH l67 CE1 CE2 ML2B 4-6.6 Through hole 8-11 Counter bore depth 5 ML1C Load carrying direction REA 12 3 REC *28 13 *10.3 6 RHC 6 MTS 12 Conveyor lower limit position CC 1 *3 R25 73 87 Stroke 2-Rc(PT)1/8 20 16 8 160 16 Pressure port at rear side Pressure port at front side 23 6.5 14 2-Plug 46 51.5 (Diagonal 62) Basic type: RSH32-20ll SRSH32A, #1 (#1+#5) With locking

Characteristics Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range. Air cushion is standard. Enables the impact to be absorbed at the stroke end when the cylinder is operated at high speeds. Cylinder position can be detected.

Characteristics Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range. Air cushion is standard. Enables the impact to be absorbed at the stroke end when the cylinder is operated at high speeds. Cylinder position can be detected.

solenoids possible.) 20 20 stations Note 1) Double wiring specifications: Single, double, 3 position and 4 position solenoid valves can be used at all of the manifold stations.