The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE20, AX, ISE20 M5 PT VERSION, 0.26455 lb

40 4B flange 60 6B flange Type Type 00 With manual drain cock 10 With auto-drain 01 With manual drain cock 11 With auto-drain Max.

From the View menu bar "parameter (A)" please click on the "parameter setting (P)". "Parameter Settings" screen will be displayed. Please click on Read". 6.3.3 Parameter setting method Please set the parameters for each actuator. Refer to "LECSS Operation Manual,chapter 5 for details of each parameter.

1 / 02 2 S / 1 S 12 12 PV PD 2 PD PVPD 01 Rc1/8 M5 M50.8PVPD 01N NPT1/8 2 01F G1/8 M5 M50.8 M50.8 M-5P ZB03 ZB04 ZB05 ZB06 PV N.C.

G33-P2-N01-X30 IR1010G33-4-01 G33-P4-N01-X30 IR1020G33-10-01 G33-P10-N01-X30 011/84 Rc NNPT FG 00.0050.2MPa 10.010.4MPa 20.010.8MPa PRECI SI O N REG U LATO R I R101BG M AX.

8 22 8 15 80 18 M6 x 1 20 40 36 M26 x 1.5 124 13 10 70 41 41.6 3 16 11 29 10 16 92 23 M6 x 1 26 50 46 M32 x 2 150 13 TF TN Nil P (Piping port) ZZ X W TT Model 12-REA25 12-REA32 12-REA40 50 Rc1/8 30 NPT1/8 137 G1/8 17 50 Rc1/8 40 NPT1/8 156 G1/8 19 60 Rc1/4 40 NPT1/4 182 G1/4 22 12-REA50/63 0 L0.2 33 B 2 x 4 x V Effective thread depth 16 2 x P (Piping port) 14 14 8 (R) D X Q Q 14.5 22 I 2

EX600-SEN4 TM EtherNet/IP (Composite 11) EtherNet (CAT5 100BASE-TX) 10/100 Mbps / SI 192.168.0 1.1254 IP DHCP Vendor ID7(SMC Corporation) Device type12(Communication Adapter) Product code203 (DLR) TM EtherNet/IP QuickConnect Web () 120 mA /PNP() /NPN() 32 DC24 V 1.0 W (SMC ) HOLD / CLEAR / ON 1 IP67() -1050 -2060 3585%RH( AC500 V1 FE DC500 V10 M FE 1057 Hz0.75 mm p-p

p ClAseies Air Cylinder Fine Lock Model High Intermediate Stopping Accuracy , 3 Types of Locking Mechanisms r Locks in Either Extended or Retracted ', 5 Bore Sizes Available Auto Switch CaPable Direction 4-5 I Product Features . .6 I Ho* To order lf, .7 I Standard Specifications 8-9 ! locf Specifications. ..'

G46-10-01 2 pcs. G27-10-R1-X209 2 pcs. G27-10-R1-X209 2 pcs. G46-10-01 2 pcs.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com L ISE30 01 25 M For positive pressure ZSE30 01 25 M For vacuum/low pressure Option 2 Piping specifications Nil None Bracket R 1/8 (With M5 female thread) 01 NPT 1/8 (With M5 female thread) A T1 Straight type 4 One-touch fitting 5/32" One-touch fiting

Box p. 105 Terminal Block Box p. 106 Lead Wire p. 107 EX600 p. 108 EX245 p. 110 EX250 p. 112 EX260 p. 113 EX120 p. 114 Manifold Exploded View [Common Parts] p. 115 Type 10: How to Increase Connector Type Manifolds p. 115 For the JJ5SY1-10, JJ5SY3-10, JJ5SY5-10/ Manifold Parts Nos.

Set pressure with a flat head screw driver. 42 Base Mounted Type Series VQ5000 Plug-in Unit Metal seal type Rubber seal type (A) 4 (B) 2 VQ5101 (A) 4 (B) 2 VQ5100 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5201 (A) 4 (B) 2 (A) 4 (B) 2 VQ5200 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5301 VQ5300 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5401 VQ5400 (A) 4 (B) 2 (A) 4

Series VQ7-8: Manifolds P.22 How to Order Manifolds P.23 Manifold Dimensions (DIN Connector Type) P.24 Manifold Dimensions (Prewired Connector Type) Manifold Options P.25 to 27 Option Dimensions P.28, 29 Manifold Option Mounting Bolt Part Numbers P.30 Manifold Exploded View P.31, 32 Manifold Specifications Sheets P.33 to 36 Safety Instructions P.37 5 Port Solenoid Valve/Precautions P.38

p p p m m m m m m m p p p p p p p p m m m m m M m M m R p m p p p m m m M m R m p R M p m p p m p m p M m m m m M m p p M m M p p m m m m p m M M m R m m m p m m p m m p p m p m p m p m m R p m m p m p m m M M m m m m p m m p M m p m p m m m m p m M p p m m R p p p p p p p p R p p p m m p m m R p m p m p m m p M p m m m m p p m p p m p m m p R m p p p R m p p p R p p m m p m m p p p p p p

2 VQ5250 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5351 (A) 4 (B) 2 VQ5350 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 VQ5451 VQ5450 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5551 (A) 4 (B) 2 VQ5550 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Parts list Parts list Description Material Note No. 1 2 3 Description Material Note No. 1 2 3 Body

(Values at the initial period) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 3 position pressure center (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 3-10-7 8 Series VQ7-6 DIN Terminal Type 2 position single : VQ7-6-FG-S single (Reverse pressure): VQ7-6-YZ-S 120.5 120.5 68.5 52 68.5 Mounting hole 2-6.5 50 50 42.5 42.5 25 25 13 (A port) 13 (B port) Manual override (R1, R2) 2-3/8 P R2 R1 A B 14 11 50 62 12 9 62

The series and their stopping accuracy are as follows: CLJ series (p.3.1-10), CLM2 series (p.3.1-18), CLG1 (p.3.127), CLA series (p.3.1-35), and CL1 series (p.3.1-50). wWhen kinetic energy acts upon the cylinder, such as when effecting an intermediate stop: There are constraints in terms of the allowable kinetic energy that can be applied to the cylinder in a locked state.