Flat bracket Dimensions L-bracket Description Part no.
V 564 H 364 K 332 J 116 J 116 J 116 V 564 J 116 K 332 V 564 V 564 V 564 K 332 K 332 K 332 Model LW53 3 Way Normally Closed Piped Exhaust LW53GG8XGB LW53GH8XGB (G or L) LW53GJ8XGB (G or L) LW53GV8XGB (G or L) LW53GK8XGB (G or L) LW53HH8XGB (G or L) LW53HJ8XGB (G or L) LW53HV8XGB (G or L) LW53HK8XGB (G or L) LW53JJ8XGB (G or L) LW53JV8XGB (G or L) LW53JK8XGB (G or L) LW53VV8XGB (G or L) LW53VK8XGB
A AA C J L L J K (4 locations) Flat washer With 4 pcs.
MLU Clevis pin and knuckle pin Rod end nut ML1C D30 d Dd9 -X d 20D C l m m t t L H B Data (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 d 7.6 9.6 9.6 13.4 L 23 27 31 38 d M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 D 16.5 18 21 26 Dd9 C 19.6 21.9 25.4 31.2 B 17 19 22 27 H 6 7 8 11 Size 25 32 40 50 Part no.
LVC DIN terminal: D Conduit terminal: T Cable 6 to 12 LVA F S Q 27.5 34 F (Q) LVH LVD LVQ LQ R C U 25 LVN C (44) R E R TI/ TIL G1/2 E PA G1/2 A H D (S) B B A H D 2-P Port size 2-P Port size PAX 2-M Thread depth N 2-M Thread depth N PB L L K K N.C.
How to find the flow rate for air/ Flow rate formulas based on the air temperature of 20C For subsonic range where P + 0.1013 < 1.89 (P + 0.1013) Q = 226S P(P + 0.1013) For sonic range where P + 0.1013 1.89 (P + 0.1013) Q = 113S (P + 0.1013) Q : Flow rate [l/min(ANR)] S : Effective area (mm) P : Pressure drop P P (MPa) P: Upstream pressure (MPa) P: Downstream pressure (MPa) How to make
Twist Selector (3 position)/VM131-01-35R, B, G, Y/VM151-01-35R, B, G, Y Panel mounted hole JIS Symbol 2 port 3 port 15N F.O.F. 0.5MPa supply 45 T.T. 3.5-15 VM100 Series VM100/Bottom Piping Basic/VM122-M5-00, VM132-M5-00 VM123-M5-00, VM133-M5-00 JIS Symbol 2 port 3 port SlA 20N F.O.F. 0.5MPa supply A L Model 7.5 VM122-M5-00 VM132-M5-00 VlA 37.5 1.5mm P.T. 3.5 VM123-M5-00 VM133-M5-00 1.5mm
Data Clevis Pin, Knuckle Pin Rod End Nut l Bore size (mm) Bore size (mm) l d B H Dd9 L C D d Part no.
Data Clevis Pin, Knuckle Pin Rod End Nut l Bore size (mm) Bore size (mm) l d B Dd9 H L C D d Part no.
CY1L CY1H CY1F Shock absorber CYP The RJ series soft stop shock absorbers fitted as standard DM10 M8 M6 M20 M14 -X (For 20) (For 10, 15) (For 6) (For 32, 40) (For 25) Technical Data 1487 CY1S Series Model Selection Selection Flow Chart Operating Conditions D: Bore size (mm) L: Stroke (mm) m: Load mass (kg) Va: Piston speed (mm/s) P: Operating pressure (MPa) E: Kinetic energy (J) Mounting
Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.
Fittings & Tubing Air Cylinders Rotary Actuators 4 x MM thread depth J Cylinder tube outer circumference: Hard chrome plated + special treatment Note 1) 0 -0.1 L H B G E 2 x P (Piping port) G NN Effective thread length T (R) D X Mounting nut width across flats C NA I N W K N F F S + Stroke ZZ + Stroke Note 1) 50, 63: L 0 -0.2 8 x V Effective thread depth Y H A B E G Mounting nut width across
x 1.25 depth 14 32 40 75 22 16 18 107 8.6 140 50 34.5 160 14 depth 10 M10 x 1.5 depth 18 37 M8 x 1.25 depth 16 45 110 22 19 23 142 10.5 170 80 37 194 17 depth 12 M12 x 1.75 depth 21 42 M10 x 1.5 depth 20 Bore size (mm) W Z Y X WH W V U T S R Q O N M L K J I P 20 25 32 40 50 30 140 80 30 23 36 40 86 12 26 12 21 M6 x 1 25 38 80 60 44 25 M5 x 0.8 30 153 80 37 25 44 47 98 13 31 12 21 M6 x 1
The result is approximately 10 L/min (ANR). Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.
CE2 ML2B ML1C Mounting Position (Stroke End)/Reed Switch Mounting Position (Stroke End)/Solid State Switch D-E73A (L), D-E76A (L), D-E80A (L) D-M5B (L), D-M5N (L), D-M5P (L) D-M5BW (L), D-M5NW (L), D-M5PW (L) D-M5NTL, D-M5PTL REA REC RHC MTS CC Lead wire clamp/Lead wire cap (option) Series Lead wire clamp Lead wire cap ML1C LC-01 LP-01 Unit: mm Lead wire clamp/Lead wire cap (option) 25 32
A B L L2 MM R1 R2 U L2 MM L1 NDd9 3 NDH10 3 NX Part no.
A B L L2 MM R1 R2 U L2 MM L1 NDd9 3 NDH10 3 NX Part no.
input No., State (P-No.) label C-AND OR input time out subroutine call command General-purpose input No., State (P-No.) label C-OR AND input condition jump command General-purpose input No., State (P-No.) label J-AND Condition jump OR input condition jump command General-purpose input No., State (P-No.) label J-OR Program Control Commands Parameter value Mnemonic Classification Function
Digital Flow Switch Unit Specifications Detection type Heat type Measured flow range 50 to 500 L/min 5 to 100 L/min Minimum unit setting 5 L/min 1 L/min Accumulated pulse flow rate exchange value (Pulse width: 50 [ms]) 5 L/pulse 1 L/pulse Accumulated flow range 0 to 9 L 5% F.S. or less (15 to 35C: Based on 25C) Linearity 2% F.S. or less Repeatability 5% F.S. or less (15 to 35C: Based on 25C