SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-P-N01-A2"

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A2 (Bracket B, Horizontal Mounting)

Refer to Fig. 4-1: Thrust force characteristics (P.9) and to Fig. 4-3: Allowable thrust force setting values (P.11) for details. Note 2) When mounted on a base with good heat dissipating capacity at 20oC ambient temperature. Note 3) The pushing force varies depending on the operating environment, pushing direction and table position. Refer to Fig. 4-1 Thrust force characteristics (P.9).

Flow Pressure characteristics Measuring method schematic 1) With high speed static neutralization cartridge 2) With Energy saving static neutralization cartridge 3) With Energy saving high-efficiency cartridge 600 1000 200 IZS4-2500 IZS4-2500 900 180 IZS4-2500 2320 2320 2320 500 800 160 1900 1900 700 140 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 1900 400 L/min

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: -

Connect head cover tubing wisely with consideration of surrounding conditions. 15 Driving Direction Left Right Brake O per ating P ort Brake Release P ort Head Cover-WL Head Cover-WR Tube Part No. 1 2 3 4 5 6 Head Cover Type Head Cover-WL Head Cover-WR Tubing Side Front Side Bottom Front Side Bottom Driving Left A C E G I K Direction Right B D F H J L Note

A22 Symbol: A23 Symbol: A24 30 30 DA L RD MM 30 MM DA 30 MM MM DB DB T T C B A H AL H A L K H A A W H H Symbol: A25 Symbol: A26 Symbol: A27 Symbol: A28 Symbol: A29 DA 30 MM MM DA 30 DA 30 30 MM L W MM A L H AL H LB K A AL A H L A H T AL L K H MM Symbol: A30 30 MM W A T H 84 Simple Specials Series CP96/C96 Symbol Change of Trunnion Bracket Mounting Position 2 -XC14 Series C85 Series

A 13 15 22 06 08 10 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 End bracket/IZS40-BE 35 22 4.5 30 18 2 x 5.4 105 33 L 33 Intermediate bracket/IZS40-BM 55 35 22 4.5 36 30 18 2 x 5.4 A 105 33 A A-A section 431 IZS40/41/42 Series Dimensions Ionizer/IZS41, 42 30 44 304 6.8 30 85 9 60 50 A 60 x (n-1) L n (Number of emitter cartridges), L Dimension L (mm) IZS4-340 IZS4-400 IZS4-460 IZS4

ZS-36-A2 2 station: 2 L-type brackets With mounting screws (M3 x 25 L) 2 pcs. ZS-36-A3 3 station: 2 L-type brackets With mounting screws (M3 x 35 L) 2 pcs. ZS-36-A4 4 station: 2 L-type brackets With mounting screws (M3 x 45 L) 2 pcs. ZS-36-A5 5 station: 2 L-type brackets With mounting screws (M3 x 55 L) 2 pcs. -11No.

(ZSE/ISE30A) P Reduction in setting w Reduction in setting work ork P Pre Prevention of mistakes in setting vention of mistakes in setting P Reduction in setting work P Prevention of mistakes in setting Cop Copy Copy 1 switch Slave pressure switch Master pressure switch (source of copy) 2 switches 10 switches 3-step setting -step setting 3-step setting 1 2 3 Push Push Adjust to the set-value

Bolt for manual release ML2B25 M50.8 L=8 ML2B32 M61 L=10 ML2B40 M81.25 L=12 37 Chapter 13: Installation & Wiring 13-1 Installation of Cylinder 1. It should be installed at high flatness surface. For uneven surface. Shim adjustment should be done to achieve smooth operation of slider with a minimum operating pressure of 0.1MPa. 2. Installed with utilizing both sides head cover.

L IZS41-CP 3000 +60 0 +100 0 IZS41-CPZ 9850 AC adapter Shield wire IZF21-CG1 (with AC cord) IZF21-CG2 (without AC cord) Inlet IEC60320-C6 33 Doc. No.: IZ-OMR0035 7.

1361213613PVQ Note 1) In the case of A1 and B1, a pressure gauge or a plug is mounted on the body side, while in case of A2 and B2, on the manifold side.

This is a legacy product, and replaced byISE30A-N01-P-L, PRESSSURE SWITCH *LQA, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, CB, ISE30 1/8 INCH NPT VERSION, .59355 lb

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)