DC 0.35 W DC 0.1 W DC (at holding) with power saving circuit Note 1) Note 1) With the 0.1 W DC specification, keep the vibration/impact within10/50 m/s2. 0.35 W DC at inrush (20 ms) and 0.1 W DC at holding.
R C R C (44) G1/2 E A H 2-P Port size B (S) E G1/2 2-M Thread depth N D A H B 2-P Port size 2-M Thread depth N D L L K K N.O.
Bore size (mm) MM W TC NA P S TA ZZ WA WH 30 30 25 20 20 20 20 20 M8 M10 X 1.25 M10 X 1.25 M14 X 1.5 M18 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5 24 29 35.5 44 55 69 80 100 M5 M5 Rc(PT)1/8 Rc(PT)1/8 Rc(PT)1/4 Rc(PT)1/4 Rc(PT)3/8 Rc(PT)1/2 77 77 79 87 102 102 122 122 11 11 11 12 13 13 M5 M6 X 0.75 M8 X 1.0 M10 X 1.25 M12 X 1.25 M14 X 1.5 147 157 159 187 218 218 264 264 16 16 16 16 18 18 22
(inch) Model H Connection thread Min. port size KQ2H01-M5 KQ2H07-M5 KQ2H01-M5 KQ2H07-M5 Note) Mass (g) (Width across flats) L A M D Applicable tubing R M KQ2H01-M5 2 9 16 6 11 12 3.3 10 15 M5 x 0.8 7 16.7 21.1 13.6 18 12.7 KQ2H01-01S 1 8 1 8 10 15.5 2.5 1 4 KQ2H01-02S 19 13.5 14 2.5 M5 x 0.8 KQ2H05-M5 10.7 10.3 24 21.1 20.5 18.4 21.6 22.5 20.5 18 15 15.3 18.5 17 8 11 14 11 16.5 1 8
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
Grommet: G Conduit: C 2-M 2-M L L K Approx. 300 K Q F D Approx. 280 D Q F C R C G (PF) 1/2 R E B A H E 2-P Port size A H 2-P Port size B DIN connector: D Conduit terminal: T 2-M 2-M L L K Cable 6.8 to 10 K 27.5 F F Q (Q) 34 S 25 U R C R C G (PF) 1/2 (44) E B A H D (S) E G (PF) 1/2 B A H D 2-P Port size 2-P Port size N.C.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
state auto switch Reed auto switch 5 V, 12 V IC circuit 12 V 5 V, 12 V 12 V IC circuit Relay, PLC Diagnostic indication (2-color indicator) 24 V Yes Grommet 5 V, 12 V IC circuit Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V 3-wire (NPN equivalent) Grommet 24 V A96V A96 IC circuit 5 V Yes A93V2 A93 A90 100 V IC circuit Relay, PLC 2-wire 12 V A90V No 100 V
DC 0.35 W DC 0.1 W DC (at holding) with power saving circuit Note 1) VZ VS VFN Note 1) With the 0.1 W DC specification, keep the vibration/impact within10/50 m/s2. 0.35 W DC at inrush (20 ms) and 0.1 W DC at holding.
DC 0.35 W DC 0.1 W DC (at holding) with power saving circuit Note 1) VZ VS VFN Note 1) With the 0.1 W DC specification, keep the vibration/impact within10/50 m/s2. 0.35 W DC at inrush (20 ms) and 0.1 W DC at holding.
In case of SJ3l60T, electric waveform of energy saving type 24 VDC Applied voltage 0 Standard products 0.4 W Indicator light A side: Orange B side: Green With power saving circuit 0.15 W Solenoid a 0 W Solenoid b 67 ms Changing the Connector Entry Direction When a power saving circuit is installed, a diode to prevent reverse current is not available for 12 V DC spec.
type (4 cores) Cable connector 3 m (33) 52 12.5 Setting part 12 M12 x 1 Cable connection thread (Plug type) 4 10.5 11 108 Digital pressure display M5 x 0.8 Solenoid valve EXH M4 x 0.7 depth 8 F.G.
R V Basic type (B)/CG5BAS : With air cushion X165US inch rod option dimensional changes WA WB Width across flats B1 Dim. GA GB 2-P Bore size A AL B1 H H1 MM ZZ W 10 M BM H1 20 14 12.7 11.0 25.4 4.0 1/4-28 108.4 25 14 12.7 12.6 28.4 4.8 5/16-24 111.4 Max.
50/60 Hz 5 24 VDC 6 12 VDC V 6 VDC S 5 VDC R 3 VDC F G Supply valve/Release valve combination Pilot valve J K Supply valve Nil DC: 1 W (With indicator light: 1.5 W) AC Supply valve and release valve A Supply valve (N.O.)
Station 16 Weight W(g) Note 2) n1: Stations n2: Number of SUP/EXH blocks m: Weight of DIN rail 3,4 W = 3.2n1 + 53n2 + m + 126.5 1,2 Note 1) This manifold is applicable to up to 16 solenoid valves.
N P Q R S T U V W X Y AV2000-02-1 to 4G(Z)-A 30 50 51.5 44 5.5 10 66 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width across flats 14 AV2000-02-5 to 6G(Z)-A AV3000-03-1 to 4G(Z)-A 41 50 53.5 46 5.5 15 70 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width across flats 19 AV3000-03-5 to 6G(Z)-A AV4000-04-1 to 4G(Z)-A 50 60 64 54 8.5 18 90 3.2 39 74 M5 x 0.8 Depth 6.5 4 Width across flats 22 AV4000-04-5 to 6G(Z)-A
C76
Construction q t e r w IN Description No.
Switch Characteristics How to Order Contact point configuration Maximum contact point capacity Operating voltage: AC, DC 1a 2 VA(AC), 2 W(DC) 100 V or less 30 X201 IS1000M 12 V to 24 VAC, DC : 50 mA 48 VAC, DC : 40 mA 100 VAC, DC : 20 mA Body size Accessory Maximum operating current Pressure switch X201 Lead wire length: 3 m Regulating pressure range: 0.1 to 0.6 MPa 20 30 40 For ACG20 X202
x 0.8 x 16 M5 x 0.8 x 20 M5 x 0.8 x 25 9-15-36 37 Solid State Switch Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) For details about certified products conforming to international standards, visit us at www.smcworld.com.