SMC Corporation of America
Elite Part Number Search
Search Results "IZF21-BY"

Communication status 0 1 By default 2 Run/stop operation of the product is carried out by the contact input signal, and by reading/writing the Change in set value of circulating fluid temperature and Operation status by serial communication.

assembly on manifold block and hold it by tightening two round screws by Phillips driver. 1) Loosen and remove round head screws of regulator assembly by Phillips head screw driver to become the regulator assembly able to be disconnected manually. 2) Rotate bonnet counterclockwise by holding its width across flats by spanner to disconnect.

assembly on manifold block and hold it by tightening two round screws by Phillips driver. 1) Loosen and remove round head screws of regulator assembly by Phillips head screw driver to become the regulator assembly able to be disconnected manually. 2) Rotate bonnet counterclockwise by holding its width across flats by spanner to disconnect.

After tightening by hand, the barb fitting type should be tightened by an additional 1/4 rotation using an appropriate wrench. 2. After tightening by hand, the barb elbow type should be tightened by an additional 1/2 rotation using an appropriate wrench. 2) M5 1. After tightening by hand, the barb fitting type should be tightened by an additional 1/6 rotation using a suitable tool. 2.

Simple and unencumbered appearance by adopting round-shaped cord.

Do not carry a rotary actuator by the auto switch lead wires. Never carry a actuator by its lead wires. This may not only cause broken lead wires, but it may cause internal elements of the switch to be damaged by the stress. 3. Mount switches using the proper tightening torque.

The actuator performance can be configured by tuning these control parameters according to the specific work load. The Card Motor can perform a pushing operation by selecting one of 4 modes of pushing force.

(Normally Open) merely by turning over the switch cover.

By using these software functions the Card Motor operation can be simulated and checked step by step. Operation Start Starts the selected step data operation. Operation End (stop) Stops the operation and the position is held. The Step Data can be executed in a sequence by selecting a Step Data and by pressing the [Operation Start] button.

(Set the pressure by turning the screw in the increase direction.)

Average speed of cylinder is obtained by dividing the full stroke time by the stroke. Load factor: ( (Load weight x 9.8) /Theoretical force) x 100% The histograms with marked are the case when piping is done by using steel.

U1 UA4640 Produced by Mitsubishi Cable Industries, Ltd.

Equal dimensions are indicated by the same marker.

Cuts air consumption by operating the return stroke at a reduced pressure.