Male Run Tee: KPY Effective area mm Note 1) D1 Model L1 TPH TPS A H (width across flats) 2-Applicable tubing Applicable tubing O.D. mm Connection threads R Weight g L1 L2 M D2 6 7 8 9 12 13 19 20 21 24 40 42 43 45.5 49 50 56 56.5 59.5 62.5 1/8 1/4 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 12 14 12 23.2 27.2 24.4 28.4 26.6 29.4 32.1 33.1 34.3 38.3 KPY04-01 KPY04-02 KPY06-01 KPY06-02 KPY08-01 KPY08-02
Male Run Tee: KPY Effective area mm Note 1) D1 Model L1 TPH TPS A H (width across flats) 2-Applicable tubing Applicable tubing O.D. mm Connection threads R Weight g L1 M L2 D2 KPY04-01 KPY04-02 KPY06-01 KPY06-02 KPY08-01 KPY08-02 KPY10-02 KPY10-03 KPY12-03 KPY12-04 1/8 1/4 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 12 14 12 23.2 27.2 24.4 28.4 26.6 29.4 32.1 33.1 34.3 38.3 40 42 43 45.5 49 50 56 56.5
Unrestricted Base mounted 300/50 SA Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
area (mm2) Rod size (mm) Bore size (mm) 0.3 0.2 0.4 0.5 0.6 0.7 34 23 OUT 45 57 68 79 113 12 6 26 17 IN 34 43 51 60 85 94 63 OUT 126 157 188 220 314 20 10 71 47 IN 94 118 142 165 236 Weights Unit: g Increase by stroke adjuster Stroke mm Weight g Increase by scraper Model Model 12 240 10 5 MIW12-12D MIW 20 650 30 10 MIW20-20D 10 130 MIS12-10D 20 160 5 3 MIS12-20D 30 190 MIS12-30D MIS 10 300
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 42 52 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 56 65 Two mounting screws (for mounting
(Nm) L(mm) MHM-16D M6x1 5.2 11.5 MHM-25D M8x1.25 12.5 12.4 MHM-32D M10x1.5 24.5 13.5 MHM-50D M12x1.75 42 16 3.
End plate ass'y 1 pc. 2500 3000 A B 146 Return to Menu Specialty Regulators NARM Series Regulator for Manifold NARM2500, 3000 P Dimensions Symbol A B C D E F G H I J K L M N O P Model NARM2500 .24 .67 1.73 2.20 1.65 4.98 2.28 1.77 .67 .83 1.50 1.65 1.14 1.89 2.68 1.32 (6) (17) (44) (56) (42) (126.5) (58) (45) (17) (21) (38) (42) (29) (48) (68) (33.5) NARM3000 .28 .83 2.13 2.68 2.17 6.04
Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications
42 21.5 18 16 18.5 182 215 281 325 144 166 188 230 Adapter Assembly Installation Procedure For details, refer to Best Pneumatics Vol. 16.
Note 2) Vibration resistance: No malfunction resulted in a one-sweep test in a 10 to 300 Hz range in the axial and right angle directions of the main valve and armature, for both energized and de-energized states. Shock resistance: No malfunction resulted in an impact test using a drop impact tester.
View A Terminal block number 4 3 2 1 1 2 3 4 5 6 7 8 8 7 6 5 16-11-42 7 Series PF2D Digital Flow Switch For Deionized Water and Chemicals Functions/PF2D Refer to the operation manual how to set and to operate. Output types Flow rate measurement selection Real-time flow rate and accumulated flow rate can be selected.
81 25.6 23 21.7 12" 13.5 H O W T O O R D E R A I R S U C T I O N F I LT E R S E R I E S (N)ZFB ACCESSORIES A I R S U C T I O N F I LT E R S E R I E S (N)ZF1B (N)ZFB E L E M E N T I-34S-A (N)ZFB100, 101 I-35S-A (N)ZFB200, 201 I-36S-A (N)ZFB300, 301 I-395-A (N)ZFB401 B O D Y S I Z E T U B E S I Z E OD M M 04 4 06 6 08 8 10 10 05 3/16 07 1/4 11 3/8 13 1/2 100 Max 20 ln/min 200 Max 50 ln/min 300
Lubrication Free Mounting position Body ported Impact/Vibrarion resistance (m/s2) (1) 300/50 Note 1) Impact resistance: Nomalfunction resulted from the impact test using a drop impact tester.The test was performed on the axis and right angle directions of the main valve and armature, when pilot signal is ON and OFF.
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 52 42 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 65 56 Two mounting screws (for mounting
T|lULTI'PURPOSE APPLICATIONS FOF USE AS: PORT'A' PORT "P" PORT "E'' Opg.ltng PrEsluEr 28" vacuum to 300 PSIG. (2oKgtcflf) 2-Way Normally Closed O!
Motion on RECL32-300 ML1C REA REC Pressure fluctuation Load fluctuation Speed fluctuation RHC 0.5 0.5 0.3 0.5 Pressure (MPa) Pressure (MPa) Pressure (MPa) Reducing actuation cycle time 10 10 30 10 Load (kg) Load (kg) Load (kg) MTS 100 300 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 CC Max. 500mm/s of high speed transfer is possible.
400 500 100 200 300 400 500 100 200 300 400 500 Elimination ratio (%) Elimination ratio (%) Elimination ratio (%) 75 70 60 50 40 30 20 10 0 1 5 10 50 30 100 1 5 10 50 100 Flow-back count Flow-back count Flow-back count Explanation of graph Explanation of graph Example: Elimination ratio and concentration after using the FHM-100 for one hour under the following conditions.
41 5 Max. 149F (65C) Max. 122F (50C) 40 Inlet air temperature 39 4 38 3 37 0 200 100 400 500 300 Flow rate [SCFM] New stainless steel heat exchanger helps reduce the load of the compressor Easier maintenance V The temperature range for normal operating conditions is indicated by the green zone.
When the analog output range is changed, check the set value and change it to an appropriate value. 42 EX## OMS1015-A No. Parameter Definition Item Content Default setting 1: True Output will be fault value. 8 Fault Mode Analog 0: False Output will be held last state.