SMC Corporation of America
Elite Part Number Search
Search Results "KRM11-06-10-10"

; price is per piece) $0.79 + Add to Quote Add To Cart Add to Cart SMC KQ2P-06 fitting, plug, KQ2 FITTING (sold in packages of 10; price is per piece) $0.92 +

AMX-OMZ0092 PRODUCT NAME Line Filter MODEL / Series / Product Number AFF50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AFF60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1. Bowl assembly for AFF50 10 6-2.

AMX-OMZ0093 PRODUCT NAME Mist Separator MODEL / Series / Product Number AM50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AM60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1. Bowl assembly for AM50 10 6-2.

AMX-OMZ0094 PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AMD50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AMD60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1.

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Abnormal low tank fluid level 1 Low tank fluid level 2 None 3 None 4 None 5 Fan failure Alarm flag 1 6 None 7 None 8 Abnormal rise of circulating fluid temperature 9 Circulating fluid temperature rise 10 Circulating fluid temperature drop 11 TEMP READY

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 CH1 abnormal low tank fluid level 1 CH1 low tank fluid level 2 CH2 Abnormal low tank fluid level 3 CH2 low tank fluid level 4 Reservation 5 Fan failure Alarm flag 1 6 Reservation 7 Reservation 8 CH1 abnormal rise of circulating fluid temperature 9

AMX-OMZ0095 PRODUCT NAME Activated Carbon Filter MODEL / Series / Product Number AMK50-(F,N)06 ~ (F,N)10(B)(-R,Z)-D AMK60-(F,N)10(B)(-R,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 6-1. Bowl assembly for AMK50 10 6-2.

to 50C (No freezing) 10 ms or less (Standard), 15 ms or less (Low wattage type) Non-locking push type Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)

Applicable Element size Element O-ring filter model mm for cover I-34S-A ZFB10 10 x 6 x L33 10 pcs. 10 pcs. I-35S-A ZFB20 12 x 8 x L42 10 pcs. 10 pcs. I-36S-A ZFB30 14 x 10 x L45 10 pcs. 10 pcs. I-39S-A ZFA401 16 x 14 x L60 10 pcs. 10 pcs. -9- < Element Replacement > 1. Stop the operation and reduce the internal pressure of the filter to atmospheric pressure. 2.

(UL standard V-0) Applicable model: ASV310F, ASV410F, ASV510F Inch size Note) Elbow: M3, M5 only Port size AS 04 06 08 10 12 03 07 09 11 13 M3 M5 U10/32 01 02 03 04 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 With One-touch fitting Thread type ASP Brass parts are all electroless nickel plated.

How to Order VCHR 06 30 G Body size Thread type (Conforming to ISO1179-1 on the pneumatic/hydraulic G thread) 30 40 Symbol Port size Port size VCHR30 VCHR40 Symbol 06 10 14 3/4 1 11/2 630 Series VCHR Direct Operated Regulator for 6.0 MPa (Relieving Type) Specifications Model VCHR30 VCHR40 Valve construction Piston type Valve material Polyurethane elastomer Relief mechanism Relieving type

T 04 06 08 10 12 4 6 8 10 12 VMG Construction Description Material Component Parts No. q w e r t y u i o !0 !

AD Accessory (Option) GD Applicable model HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Screw flange (With companion flange) HAWF-141 HAWF-142 HAWF-200 HAWF-200 Auto drain AD402-04 AD600-06 AD600-10 Model Selection (Flow Capacity l/min (ANR)) JIS Symbol Model HAW2-04 HAW7-06 HAW22-14 HAW37-14 HAW55-20 HAW75-20 HAW110-30 50C 2000 6000 12000 12000 12000 18000 1000 70C 100C 180C Inlet air temperature

HA Accessory (Option) AT HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Applicable model Screw flange (With companion flange) HAWF-141 HAWF-142 HAWF-200 HAWF-200 ID Auto-drain AD402-04 AD600-06 AD600-10 AMG Model Selection (Flow Capacity l/min (ANR)) AFF HAW2-04 HAW7-06 HAW22-14 HAW37-14 HAW55-20 HAW75-20 HAW110-30 Model 1000 70C 100C 180C 50C 2000 6000 12000 15000 22000 30 Inlet air temperature

VHS20/30 VHS40/40-06/50 2-10 I 10 I G H F E X H .

Compact size (Width: 18 mm) Low power consumption: 1.8 W DC Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50C (No freezing. Refer to page 3-13-4.) 20 or less 50 or less 10 3 Refer to the table below.

Recommended flow rate Note) (l/min (ANR)) Mass (g) Internal capacity (cm3) 1.7 ZA Model IN side, OUT side 2 3.2 4 4 6 6 8 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" ZFC050-02 ZFC050-23 ZFC050-04 ZFC100-04 ZFC100-06 ZFC200-06 ZFC200-08 ZFC051-01 ZFC051-03 ZFC101-03 ZFC101-07 ZFC201-07 ZFC201-09 2 7 10 10 20 30 50 7 10 10 20 30 50 4.9 ZX 1.7 4.3 IN/OUT straight piping Metric size ZR Easy installation

Mounting/ Piping Equivalent tightening torque [Nm] KF 04 1.5 to 2.0 2 to 7 KF 06 1.5 to 2.0 3 to 8 KF 08 1.5 to 2.0 4 to 9 KF 10 1.5 to 2.0 6 to 9 KF 12 1.5 to 2.0 9 to 12 KF 04 1.5 2 to 4 KF 06 1.5 4 to 6 KF 08 1.5 6 to 9 KF 10 1.5 10 to 12 KF 12 1.5 10 to 12 Sleeve material Fitting size Appropriate tightening rotations Nylon 66 C2700 2.

Compact size (Width: 15 mm) Low power consumption: 1.8 W DC Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50C (No freezing.