Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.18 to 0.7, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7A2
Diameter(φ): 20, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.08~1, Cushion: Rubber cushion, Specification: Built-in magnet, Auto Switches: H7A2
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: Rc, Auto Switches: H7A2, Lead Wire Length(m): 0.5
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: Rc, Auto Switches: H7A2, Lead Wire Length(m): 3
Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1/2", Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Number: 1 pc.
Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1", Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Number: -
Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1", Port Location: In-line, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Number: -
Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1 1/2", Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Number: -
Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7A2
Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: H7A2
Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7A2
Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7A2
Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7A2
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): null~1.0, Port thread type: Rc, Auto Switches: H7A2, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: H7A2, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: H7A2, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: H7A2, Lead
Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7A2
Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7A2
Inner Diameter(φ): 20, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7A2