Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate), Made to Order:
Series: 25A-PF3W5, Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment: w/Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G [Instantaneous Flow: L/min (gal/min); Temperature: °C/°F], Bracket: w/Bracket
Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Piping Material Brass
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate, Made to Order: EPDM Seal Material
Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 1.98416 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeWithstand pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput Note 2)specificationsPower
Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EA, IFW/PFW 3/8INCH PT VERSION, 1.66230 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeWithstand pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput Note 2)specificationsPower
Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EA, IFW/PFW 3/8INCH PT VERSION, 1.92154 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeWithstand pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput Note 2)specificationsPower
Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 1.69020 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeWithstand pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput Note 2)specificationsPower
(50%)Karman vortex0.5 to 4 l/min0 to 1 MPa1.5 MPa0 to 90C (with no cavitation)?
Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EA, IFW/PFW 3/8INCH PT VERSION, 1.97366 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeWithstand pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput Note 2)specificationsPower
Nozzle Diameter: ø1.8mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: Screw-in NPT 3/8, VAC: Screw-in NPT 3/8, EXH: Screw-in NPT 3/8, Accessories: -
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 162, Vacuum Port Connecting Port Shape: [Others] NPT3/8, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: NPT3/8, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C):
Nozzle Diameter: ø1.8mm, Vacuum Pressure: -89 kPa, SUP: Screw-in NPT 3/8, VAC: Screw-in NPT 3/8
Nozzle Diameter: ø1.8mm, Vacuum Pressure: -48 kPa, SUP: Screw-in NPT 3/8, VAC: Screw-in NPT 3/8
Nozzle Diameter: ø1.8mm, Vacuum Pressure: -90 kPa, SUP: Screw-in NPT 3/8, VAC: Screw-in NPT 3/8, EXH: Screw-in NPT 3/8, Accessories: w/o Bracket, w/o Silencer
Nozzle Diameter: ø1.8mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: Screw-in NPT 3/8, VAC: Screw-in NPT 3/8, EXH: Screw-in NPT 3/8, Accessories: w/o Bracket, w/o Silencer
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -66, Air Consumption Flow Rate(l/min): 113, Vacuum Port Connecting Port Shape: [Others] NPT3/8, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: NPT1/4, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C):
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 113, Vacuum Port Connecting Port Shape: [Others] NPT3/8, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: NPT1/4, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C):
The modular design of the AR series connects with other SM, REGULATOR 1/8 *LQA, AIRLINE EQUIPMENT, AR REGULATOR, ED, AR 3/8INCH STANDARD (NPT), 0.44 lb
Regulator manifold series ARM is available in standard size 1000 & 2000 and the modular style is available in sizes 2500 & 3000. Standard models are available with 4 connection methods and have backflow function availability. Modular styles can be freely mounted on a manifold station and have easy set up using the new handle. Regulator manifold, modular type, NPT type threads, Optimal for