Pad Diameter: ø25, Pad Material: N (NBR), Vacuum Entry: N01 (NPT 1/8)
Pad Diameter: ø40, Pad Material: N (NBR), Vacuum Entry: N01 (NPT 1/8)
This is a legacy product, and replaced byZSE20F-N-N01-L, VACUUM SWITCH, *LQA, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .38827 lb
Adapter Material: Brass, Standard, Vacuum Inlet Direction: T (Vertical), Pad Diameter: ø20, Pad Styles: C (Flat w/Ribs), Material: N (NBR), Vacuum Entry: N01 (Female Thread, NPT 1/8)
This is a legacy product, and replaced byISE20-N-P-N01-L ISE30/ISE30A PRESSURE SWITCH. SWITCH. INSTRUMENTATION. ISE30 1/8 INCH NPT VERSION. .16640 lb. CB.
M5 Port size M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Type 01 02 03 04 U10/32 N01 N02 N03 N04 Elbow Universal 2 3 Universal type Applicable tubing O.D.
8.4 12.7 AS221F-01-04SD AS221F-N01-01SD 1/8" 8.4 4 9.3 27.5 20.4 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-01-06SD AS221F-N01-03SD 6 11.6 13.5 35.6 R 1/8 14.2 7.2 1.2 31.6 12 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-01-08SD AS221F-N01-05SD NPT 1/8 12.7 14.2 7.2 35.6 1.2 31.6 8 15.2 18.5 32.4 25.3 AS221F-01-10SD AS221F-N01-07SD 1/4" 13.2 23.9 31 18.5 10 18.5 21 40.2 33.1 15 AS221F-02-04SD AS221F-N01
Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION, 0.84315 lb
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Metric size Inch size Model Port size Pilot port 6 8 10 12 1/4" 5/16" 3/8" 1/2" ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 ASP330F-N01 ASP430F-N02 ASP530F-N03 ASP630F-N04 R 1/8 M5 x 0.8 R 1/4 Rc 1/8 R 3/8 Rc 1/8 R 1/2 Rc 1/4 R 1/4 G 1/8 R 3/8 G 1/8 R 1/2 G 1/4 NPT 1/8 10-32 UNF NPT 1/4 NPT 1/8 NPT 3/8 NPT 1/8 AS NPT 1/2 NPT 1/4 Note
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter for w/Flow Adjustment Valve
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,
Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION, .00000 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air
or 2s can be chosen., Easy connection and removal of wiring., DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)