Rated voltage AC[V] C[ F] R[ ] Test voltage AC[V] Outline drawing [Unit: mm] Vinyl sheath 200 0.5 50(1W) Across 18 1.5 Blue vinyl cord Red vinyl cord T-C 1000 (1 to 5s) 6 10 or less 10 or less 10 3 10 3 4 15 1 31.5 1 200 48 1.5 200 or more or more Note that a diode should be installed to a DC relay, DC valve or the like.
Heat exchange plate Circulating Circulating Reservoir fluid OUT fluid IN DC pump Temp. sensor Heat sink Thermo-module DC fan DC fan Filter Fig.4-5 Circulating fluid circuit HEC002-A/HEC006-A 4-3 Unit Overview 4.6 Functions 4.6.1 Auto tuning This function sets the values necessary for the control system such as PID (proportional band, integral time, derivative time and ratio of cooling/ heating
Confirm the effect of the static neutralization after installation. 3) When installing Ionizers which operate in DC mode (one polarity, positive or negative) close together, they should be positioned at least 2m away from each other. When an Ionizer is used close to the Ionizer which operates in DC mode, separate them by at least 2m.
Without indicator light: 4.8 W, With indicator light: 5 W ZNR (Varistor), Neon bulb Diode, LED (Neon bulb for 100 V or more) How to Calculate the Flow Rate Inrush Holding (3) (4) Apparent power AC For obtaining the flow rate, refer to page 4-1-6. (3) (4) Power consumption Light/Surge voltage suppressor (Not applicable for grommet type) DC AC DC Courtesy of Steven Engineering, Inc.-230 Ryan
Example 1) In the case of VT317-001GB-05 Example 2) In the case of PVT317-5G Caution When the rated voltage is AC and if it is assembled with the coil for DC, response may be delayed and occur malfunction. Also, for DC valves, when the coil for AC is assembled, it occurs malfunction. For AC valves, assemble the coil for AC, and for DC valves, assemble the coil for DC.
1 Direct Operated Solenoid Valve Metal Seal Series VS4 10 Model Flow characteristics Max. (1) operating cycle (cpm) (3) VK Response (2) time (ms) Weight (kg) Model Port size Rc (Nominal size) Number of positions JIS Symbol P A/B A/B EA/EB VZ C [dm 3/(sbar)] C [dm 3/(sbar)] b b Cv Cv AC DC AC DC AC DC VS4110-01 (6A) 3.2 3.2 0.42 0.37 0.86 0.80 1 8 2 (Single) 1,200 180 13 or less 45 or less
Note that for DC units, idle time and return time increase if the voltage is lowered. If a surge voltage suppressor is installed, the return speed decreases. 32 Series VXF2/VXFA2 Specific Product Precautions 2 Be sure to read before handling.
CQM Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Auto switch model Lead wire length (m) Indicator light Electrical entry Type Special function 3 (L) Perpendicular In-line 0.5 (Nil) 5 (Z) 1 (M) MU M9N M9P M9B M9NW M9PW M9BW M9NV M9PV M9BV M9NWV M9PWV M9BWV 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire IC circuit IC circuit 5 V, 12 V Solid state
(+) 1.2K (Brown) DC (+) (Gray) Analog output (Gray) Auto shift input Main circuit Main circuit Main circuit Main circuit Load Load 1k 12VDC to 24VDC Load Load 6.8K 12VDC to 24VDC (Black) OUT 1 (Black) OUT 1 (White) OUT 2 (White) OUT 2 (Blue) DC () (Blue) DC () ZSE F/ISE --62(L)-(M) 50 60 50 60 ZSE F/ISE --70(L)-(M) 50 60 50 60 With analog output With auto shift input (Brown) DC (+) 1.2K
HYS Indicator light SE1(L)-18/-19 I Z Brown DC (+) Lead wire 0.2 to 0.33 mm2 Max. coating O.D. 1.7 mm Black OUT1 Socket LED Red Hook White OUT2 1 k Connector DC polarity indicator SE1(L)--16/-17 I Z Blue DC () With pressure setting trimmer 1 (SET 1), OUT 1 (Black lead wire, Red LED) can be set.
Connect with corresponding power side. a(+, *)indicate the direction of DC solenoid valve with tight or with surge vottage suppressor. However reverse direclion wiring is also possible in some cases. DIN connector (Wiring) Ground t l j + + H z t l 3 o o @ry a (+,-) indicate the direction of DC Solenoid valve with tight, surge vollage supprc$sor. NVFS valves can be used negative (-) COM.
Holding Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Note) At rated voltage Made to Order Specifications (For details, refer to page 3-3-85.) Option Part no.
mA] (1) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush (1) Apparent power (VA) [Current mA] AC Refer to pages 3-3-74 to 3-3-84 for manifold use. 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Holding (2) Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Made to Order Specifications
Lever SE1(L)-55 I Z 0.2 to 0.33 mm2 Max. coating O.D. 1.7 mm Brown DC (+) Lead wire Socket Connector DC polarity indicator Lever Pin Slot Housing Main circuit of switch Hook Black OUT +21LED Red Blue DC () Pressure setting trimmer 1 Pressure setting trimmer 2 SET1 2.
Electrical entry G H L LN LO Nil Grommet type, with 0.3 m lead wire (applicable to DC) Grommet type, with 0.6 m lead wire (applicable to DC) L plug connector, with 0.3 m lead wire L plug connector, without lead wire (applicable to DC) L plug connector, without connector (applicable to DC) Air operated/Without valve Pilot valve DC: 1 W (With indicator light: 1.05 W) DC: 0.45 W (With indicator
(42 mA), 0.5 W DC (21 mA) (3) 24 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Note (3) 12 VDC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 200
Switch Characteristics Contact point configuration Maximum contact point capacity Operating voltage: AC, DC 1a 2 VA(AC), 2 W(DC) 100 V or less 12 V to 24 V AC, DC: 50 mA 48 V AC, DC: 40 mA 100 V AC, DC: 20 mA Maximum operating current 25 Series AC Accessories (Spacers/Brackets) Spacer AC AFARAL AWAL AFAR AFAFMAR AWAFM AF AFM / AFD AR AL AW Attachment Center of F.R.L. body D X-X B C X Y200
) 100V or less 12V to 24V AC, DC: 50 mA 48V AC, DC: 40 mA 100V AC, DC: 20 mA Contact point configuration Maximum contact point capacity Operating voltage: AC, DC Note 1) in the model numbers indicates a thread type.
Basic type Pilot Solenoid Valve Specifications VEX5511/5711/5911/5501/5701/5901 SF4--20 Grommet (G), Grommet terminal (E), Conduit terminal (T), DIN terminal (D) Pilot valve Model Electrical entry Coil rated voltage (V) AC (50/60Hz) DC Allowable voltage 100 V, 200 V, Other (Option) 24 V, Other (Option) 15 to +10% of rated voltage Inrush AC Holding DC 5.6 VA (50Hz), 5.0 VA (60Hz) 3.4 VA (50Hz
(42 mA), 0.5 W DC (21 mA) 3 position exhaust center 12 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) 2 position double (Metal) (A) 4 (B) 2 (A) 4 (B) 2 100 VAC Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) Power consumption (Current) 110 VAC Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 1 (P) 5 (R1) 3 (R2) 200 VAC Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 1 (P) 5 (R1) 3 (R2) 220 VAC Inrush