size Lubrication Model Rubber Air M3 x 0.5 12-CY3B6 6 300 50, 100, 150, 200 M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250

Condition: Pressure 0.5MPa, Load 50%, Piping length 5m Effective area mm 2(Cv ) Cylinder speed (mm/s) 50 63 80 100 125 140 Bore size (mm) 160 180 200 250 300 Port size Rc(PT) 40 250 25(1.4) VEX312 -01, 02 500 750 02 ( 1 4) 60(3.3) 250 500 750 250 500 750 500 750 1000 500 750 1000 250 500 750 250 500 750 VEX332 -02, 03, 04 Body ported Base mounted 03 (3 8) 160(8.9) VEX350 -04, 06, 10 06 (3

m 400 1 m 350 Displayed value 300 5 m 250 200 150 100 50 0 0.5 0.4 0.3 0.2 0.1 0 Actual distance [mm] Nozzle Shape Internal Circuit and Wiring Example ISA3-N NPN (1 output) The nozzle shape must be similar to Fig. 1.

The guideline is 80% or less. 0 to 100 % 7 Effective load ratio The continuous effective load torque is displayed. The effective value is displayed relative to the rated torque of 100%. 0 to 300 % 8 Peak load ratio The maximum torque is displayed.

Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.

VCW 20 1 G Clip Series Lead wire length 20 30 40 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 Class 2 Class 3 Class 4 Flat head screwdriver Voltage Solenoid coil 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Electrical entry Insert a flat head screwdriver into the hook section of the clip groove.

Relation between clamp arm length and maximum clamping force The length of the clamp arm L should be the length given below or less. operating pressure 0.5 MPa 5000 Arm length L Model 4000 Clamping force (N) CKZ3N50 CKZ3T50 CKZ3N63 CKZ3T63 150 mm 63 3000 300 mm 2000 50 1000 0 350 300 250 200 150 100 50 0 Arm length L (mm) Series CKZ3N Allowable load for clamp arm end Refer to the graph on

300 400 200 VXB215 B E(H) 100 300 400 500 600 200 VXB215 C F(H) 100 300 400 500 600 700 800 200 Flow rate Q [kg/h] How to read the graph The sonic range pressure to generate a flow rate of 300 kg/h is P1 0.3 MPa for the VXB215C F(H).

Speed Vc Acceleration Aa Speed [mm/s] Total travel distance S Time [s] Positioning time Tp LAT3LAT3MLAT3FShortest positioning time [ms] 600 350 700 Shortest positioning time [ms] Shortest positioning time [ms] Load weight1000g Load weight1000g Load weight1000g 300 600 [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g

ZX 36 A VJ10 ZR Rated voltage Lead wire length ZM (Mounting hole) Symbol L (mm) Symbol Rated voltage Lead wire color Nil 6 10 15 20 25 30 1 300 100 VAC 50/60 Hz 110 VAC 50/60 Hz (115 VAC 60 Hz) Blue (2 pcs.)

The result is approximately 50l/min. 100 50 1 0 2 3 4 5 6 7 Cycle (Hz) Viscosity characteristics (flow rate correction for viscous fluids) Caution 100 1. These flow rate characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2.

Operating temperature range (C) 5 to 60 Standard Strokes Bore sizes (mm) Standard strokes (mm) Max. manufacturable stroke (mm) 16 100, 200, 300, 400, 500, 600, 700 800, 900, 1000, 1200, 1400, 1600 1800, 2000 3000 20, 25, 32, 40, 50, 63 Strokes can be manufactured in 1mm increments, up to the maximum stroke.

Symbol Name Initial value Unit PC01 STA Acceleration time constant 0 ms PC02 STB Deceleration time constant 0 ms PC05 SC1 Internal speed command 1 100 r/min PC06 SC2 Internal speed command 2 500 r/min PC07 SC3 Internal speed command 3 1000 r/min PC08 SC4 Internal speed command 4 200 r/min PC09 SC5 Internal speed command 5 300 r/min PC10 SC6 Internal speed command 6 500 r/min PC11 SC7 Internal

Operating time 20 s 30 s Voltage 10 s 5 s Min. 2 s dV dt 1 s = Voltage increase ratio 0.5 s dV 0.2 s 0.1 s Time 0.05 s 0.02 s dt 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 < For option B [With earth leakage breaker]> 3. This product is installed with a breaker with the following operating characteristics.

Rated voltage G: Grommet (Lead wire length: 300 mm) D: DIN terminal DO: DIN terminal H: Grommet (Lead wire length: 600 mm) 50 60 1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 240 VAC, Hz Other (Without connector) 50 60 50 60 50 60 4 5 6 7 50 60 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside

+100 OFF GND 30 msec. 1 [ooo] 1 [ooo] [F20] [iNP] [iNP][-] [-] [F20] -47No.PF-OMM0004-D [F22] 5 V20 mA [F22] [AnA] [AnA][-] [F22] -48No.PF-OMM0004-D OFF ON 5 V 20 mA 10% [F22] -49No.PF-OMM0004-D [F30] OFF 2 5 100 24 5 5 100 500 9.5 2 2 100 200 3.8 [F30] [SAVE] [F30] 2 5 OFF OFF 2 5 B -50No.PF-OMM0004-D [F80] 12% 30 ON [F80] [dSP] [F80] ON 30 OFF -51No.PF-OMM0004-D [

Port size Nil N M12 3m lead wire with connector Without lead wire Port size Applicable model Flow rate (l/min) Symbol 4 16 40 100 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Output specification Symbol Nil 1 2 Specification Series PF2W300 Series PF2W200/300 Series PF2W300 Applicable display unit (monitor) model Output for display unit Output

20 MXP16-30 MXP16-20 MXP16-30 0.08 0.12 0.06 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 0.10 Table deflection (mm) Table deflection (mm) Table deflection (mm) 0.06 0.04 0.08 0.04 0.06 0.04 0.02 0.02 0.02 0 0 0 50 200 250 Load (N) 150 100 50 200 250 Load (N) 150 100 100 400 500 Load (N) 300 200 1 N = 0.2248 lbf 165 Series MXP Precision Air Slide Table Construction

The result is approximately 50l/min. 100 50 1 0 2 3 4 5 6 7 Cycle (Hz) Viscosity characteristics (flow rate correction for viscous fluids) Caution 100 1. These flow rate characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2.

Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04 Without light SY100-82-1 Caution With light Rated voltage Voltage symbol Part number 24 VDC 24 VN SY100-82-3-05 12 VDC 12 VN SY100-82-3-06 100