HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15

Current (% for chiller main breaker volume) HRS100-A/W-20 4 h 2 h 1 h 4 min 6 min 10 min 14 min 20 min 30 min 2 min 1 min Operating time 20 s 30 s 10 s Max. 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 5000 6000 7000 10 1500 Current (% for chiller main breaker volume) 28 Series HRS100/150 Specic Product Precautions 5 Be sure to

HRS100-A/W-20/40, HRS150-A/W-40 4 h 2 h 1 h 4 min 6 min 10 min 14 min 20 min 30 min 2 min 1 min Operating time 20 s 30 s 10 s Max. 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 5000 6000 7000 10 1500 Current (% for chiller main breaker volume) 123 HRS100/150 Series Specific Product Precautions 5 Be sure to read this before handling

4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated steam holding heat (kcal/kg).

Load DOCOM (Note) 24 V DC 10% 300 mA Note. If the voltage drop (maximum of 2.6 V) interferes with the relay operation, apply high voltage (maximum of 26.4 V) from external source. -12- 4. Axis No. settings Set the control axis No. with the rotary switch.

1 100 50 10 1 10 10 10.1 5.1 1.1 0.2 10.1 5.1 1.1 0.2 Speed (mm/s) Speed (mm/s) 40 40 2.6 1.3 0.3 0.1 2.6 1.3 0.3 0.1 80 80 1.3 0.7 0.2 0.1 1.3 0.7 0.2 0.1 For transfer load of 1kg For transfer load of 3kg Positioning time (sec) Positioning time (sec) Positioning distance (mm) Positioning distance (mm) 100 100 50 10 1 50 10 1 10 10 10 10.1 5.1 1.1 0.2 5.1 1.1 0.2 Speed (mm/s) Speed (mm/s

Parameter Definition Item Content Default setting 0: -10..10 V 1: -5..5 V 2: -20..20 mA 3: 0..10 V 5 Analog Range Set the analog input range per channel. Selects the analog input range. 0..10 V 4: 0..5 V 5: 1..5 V 6: 0..20 mA 7: 4..20 mA 0: None None 6 Analog Filter Sets analog input filtering time per channel.

10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40 50 60 70 80

A2 10 11 12 17 Model A1 6 10 10 11 MXF8 MXF12 MXF16 MXF20 A3 6 10 10 11 A4 21 23 28 34 A5 21 23 28 34 A6 10 11 12 17 Graph (2) Allowable Moment Coefficient: Note) Note) MXF8 MXF12 MXF16 MXF20 1.0 Allowable Moment Coefficient: Note) 16 mm for MXF8-10 only. 0.7 Stroke (mm) Table (4) Maximum Allowable Moment: Mmax (Nm) 0.5 0.4 Model 10 0.56 100 18.27 75 7.96 13.70 50 3.34 5.69 9.14 30 0.98

(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V) Output for display unit Output Note 2) specifications Environment Voltage output 1 to 5 V Accuracy: 5%F.S., Min. load impedance: 100 k (Output impedance: 1 k) Analog output Current output 4 to 20 mA Accuracy: 5%F.S., Max. load impedance: 300 or less (at 12 VDC), 600 or less (at 24 VDC) 12 to 24 VDC 10% Power

ble acting Single rod o12, o16/5to30 o20, o2t5 io 50 o32, @40l5lo 1N o50, 063/10 io 1m Double rod 612, E1U5lo 30 amlo @Q/5to50 o50, 0631 0 to 50 Large bor lize Double acting Single rod101o 300 Double rod 10 to 300 Standard Double acting Single @d o12. a16/5 lo 3A o20 p2t510 50 o32, o40l5 to 1 00 o50 to o10cy10 to 100 Double rod 012, 016/510 30 a20. o25/5 lo 5A 632, 64US lo 1OA o50 lo 0100

mm H: Lead wire length 600 mm M: With lead wire (length 300 mm) L: With lead wire (length 300 mm) Note) S type is not available with AC mode, since a rectifier prevents surge voltage generation.

Beler 10 tab e ar bn br derais. a5-jcylinder stroke (mm) Refer to Stroke Va alionslabe ,i6)air cusnion ffi Wilh ancushion applcab e ior N4&Ltypeonly 300 400 t t t t t l l l r t t t t t t l t t t l l l l l @Loct< position 350 Rear lock iiManual release type Hffi gAuto switch type + Beler to cataoq and Besr Pneumalcs iordelails. @Number of auto switches 2 pcs.

Operating: 0 to 50C, Stored: 10 to 60C (with no freezing and condensation) Resistance Operating or Stored: 35 to 85%RH (with no condensation) 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.

IN side OUT side Fitting size Straight Elbow Elbow Elbow Straight Elbow Elbow Elbow R S T U V W X Y 4, 5/32 2.5 6 11 35.5 6 3 12.5 19 35.5 3 6.5 11 36 1/4 3 12.5 19 35.5 6.5 6 11.5 38.5 8, 5/16 5 13.5 21 38.5 ARM5AB Centralized supply type (DIN rail mount) n = Number of stations for regulator block L2 L2-10.5 L1=(14 x n)+56 11.5 Y Pressure gauge (Accessory) 10 10 14 14 16 10 10 5.3 W V T

size (mm) 4 5 7 10 Symbol 4 5 7 10 Class 3 Class 4 Voltage 1 2 3 4 5 6 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC Manual override None Slotted locking type (tool required) Nil B Consult SMC regarding other voltages.

Valve 10-VQD1000 Dimensions Plug lead unit manifold: 10-VV4QD15Lead wire length 300 mm Indicator light 4 x Rc1/8 (P, R port) 2-4.5 (Mounting hole) 57.5 52.5 51 1(P) 3(R) 1(P) 3(R) 32 16 17 9 10 P=11 10 4 4 36.5 L2 L1 41.5 45 M plug connector (M) D side Stations U side 1 2 3 4 5 n Direct manual override (Non-locking) 2n-C4, M5 (A, B port) C4: 4 One-touch fitting M5: M5 thread 2(B) 2(B) 27.5

Flow rate L/min (ANR) Flow rate L/min (ANR) Condition: Inlet pressure 0.7 MPa Condition: Inlet pressure 0.5 MPa ARM11AA1-312 (One-touch fittings: IN 10, OUT 6) ARM11AA1-312-1 (One-touch fittings: IN 10, OUT 6) 0.35 0.7 0.6 0.30 Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 250 300 0 50 100 150 200 Flow rate L/min (ANR) Flow