VXS VXS VXB VXE (3) Formula for flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + T When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + T Conversion with sonic conductance C: VXP VXR VXH VXF VX3 VXA S = 5.0 x C(5) Q : Air flow rate[L/min(ANR)] S : Effective area [mm2] P1 : Upstream pressure [MPa] P2 : Downstream

Series MXP/MXPJ6 11226, 10, 12, 16 Air Slide Table How to Order Clean series 11 Vacuum suction type MXP 11 12 15 M9N MXP 22 12 15 M9N Copper, fluorine and silicone-free + Low particle generation Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. 22 Vacuum suction type Bore size Stroke (mm) Auto switch 6 10 12 16 5, 10 10, 20 15, 25 20, 30 Nil Without auto switch Refer to the table below

(rad/s) : Rotation angle.(rad) 180 = 3.14rad t: Rotation time.

Valve model VCW2 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCW3 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW4 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket) are included

LVH VNB1 VNB12 1 4 12 (P1) 12 (P1) LVD External pilot solenoid Valve Specifications LVQ Fluid Water/Oil/Air/Vacuum, etc. 5 to 60C (1) 2 (B) 1 (A) 2 (B) 1 (A) VNBA Fluid temperature LQ 5 to 99C (1) (Water, Oil etc.

Do not drop, bump or apply excessive impacts (300m/s or more for reed switches and 1000m/s or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

(Sinking type) 12 to 24[V DC] NPN transistor MAX80[mA] MAX30[V] Main circuit Load Detection Switch Fig.1 Connection example of NPN output PLC High level 12 to 24[V DC] MAX80[mA] MAX30[V] Main circuit Load No current flow. Load is not powered. Fig.2 Equivalent circuit of an NPN switch with the output off PLC Low level 12 to 24[V DC] MAX80[mA] MAX30[V] Main circuit Load Current flows.

S 6-2. XLD-63 XLD-80 XLD-25 XLD-40 XLD-50 XLD-100 XLD-160 0.08 Nm 0.3 Nm 6-3.S S S S 6-4.M M M S 6-5./ S M S M 12 XL-OMY0002 7.

67 18 190 210 135 11 200 42 194 Rc(PT) 35 142 115 M10 95 J I GR GQ GL P Q U O T N S W K L M R V Bore size (mm) 20 25 32 40 60 35 4 4 5.5 M5 X 0.8 93 M6 X 1 16 25 26 50 80 50 12 53 105 112 70 40 7 7 9 M5 X 0.8 M8 X 1.25 20 32 31 60 95 60 12 63 125 132 103 1/8 Rc(PT) 70 40 7 7 9 M8 X 1.25 20 32 38 60 95 125 60 12 132 63 104 1/8 Rc(PT) 45 8 8 11 M8 X 1.25 25 38 47 70 75 12 73 150 162 115 82.5

2 Maximum speed 300(mm/s) or less 10 1 20 16 0.1 10 6 0.01 20 40 60 80 100 0 Overhang L(mm) 1 kg = 2.2046 lb 28 Compact Slide MXH Series Model Selection Method Selection Graphs 4 to 12 (Horizontal Mounting) Maximum speed 100mm/s or less Maximum speed 300mm/s or less Maximum speed 500mm/s or less Graph 4 Load eccentricity 50mm Graph 7 Load eccentricity 50mm Graph 10 Load eccentricity 50mm

m AFJ20-02-40-S/AFJ30-03-40-S/AFJ40-04-40-S AFJ20-02-40-T/AFJ30-03-40-T/AFJ40-04-40-T 12 12 AFJ20-02-40-T AFJ30-03-40-T AFJ20-02-40-S AFJ30-03-40-S AFJ40-04-40-S 10 10 Pressure drop [kPa] Pressure drop [kPa] 8 8 AFJ40-04-40-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 40 m Large flow type Nominal filtration rating: 40 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate

LED in pairing mode (Wireless Base) -105No.EX-OMV0017-C (12) Click the Refresh button to update the information in the setting tab window.

LED in pairing mode (wireless master) -104No.EX-OMV0017-B (12) Click the Refresh button to update the information in the setting tab window.

LED in pairing mode (wireless master) -104No.EX-OMV0017-A (12) Click the Refresh button to update the information in the setting tab window.

Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-M090 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.

In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction 2-wire s 3-wire Wiring type NPN PNP Output type 24VDC relay, PLC s s IC circuit, Relay, PLC Applicable load 5, 12, 24VDC (4.5 to 28V) Power supply voltage 10mA or less Current consumption 24VDC (10 to 28VDC) 28VDC or less Load voltage 40mA or less s 5 to 40mA 80mA or less Load current 0.8V or less

204 100 10 26 M26 x 1.5 23 100 1/2 21 130 40 204 4 End Lock Cylinder Series CBG1 With front lock: CBG1BN Bore size Stroke R GB (mm) Bore size (mm) DL1 GB S TB ZZ 20 19.5 10 (12) 80 (88) 11 117 (125) 25 19.5 10 (12) 80 (88) 11 122 (130) 32 20 10 (12) 81 (89) 10 (11) 123 (131) 40 19 10 (13) 87 (96) 10 (12) 139 (148) 50 23.5 12 (14) 102 (114) 12 (13) 162 (174) DL1 63 23.5 12 (14) 102 (114

0(0) 0 o 12. 2 4(7.a B 1(0) 8 10{6. 83 88 104 0(0) 0(3) 2.5{6.5) 4.5 B 1.5(O) 1 . 5 s.st2) 8.s{4.5) 10.5 38 ,t3.5 50.5 B 3(O) 3 10{6) 12i3. = H s 40 43.5 49 55.5 42 50 B 3(0) 3 7 10(6) 12 38 50.5 59 B 3(0) 7.4 10.5(6) 12.5 40 43.5 4S 55.5 35 42 50 Acrtssofies $eries CLA Di mensions Of Accessories lType Single Knuckle Joint Y Type Double Knuckle Joint Malerial: Free cutting sulfer steel l

0(0) 0 o 12. 2 4(7.a B 1(0) 8 10{6. 83 88 104 0(0) 0(3) 2.5{6.5) 4.5 B 1.5(O) 1 . 5 s.st2) 8.s{4.5) 10.5 38 ,t3.5 50.5 B 3(O) 3 10{6) 12i3. = H s 40 43.5 49 55.5 42 50 B 3(0) 3 7 10(6) 12 38 50.5 59 B 3(0) 7.4 10.5(6) 12.5 40 43.5 4S 55.5 35 42 50 Acrtssofies $eries CLA Di mensions Of Accessories lType Single Knuckle Joint Y Type Double Knuckle Joint Malerial: Free cutting sulfer steel l\