The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SV1000 SOLENOID VALVE, 5-PORT. SV1000 NO SIZE RATING. VALVE. SV1000 NO SIZE RATING. 0.22046 lb. 2F.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SV1000 SOLENOID VALVE, 5-PORT. SV1000 NO SIZE RATING. VALVE. SV1000 NO SIZE RATING. 0.39683 lb. 2D.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), ENDPLATE (SV1000), VALVE, SS5V1 MANIFOLD SV1000, 12, SS5V1 OTHER SIZE RATING, .16500 lb
Proper tightening torque (Nm) Connection thread size (R, NPT) 3 to 5 8 to 12 15 to 20 20 to 25 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 1 8 1 4 3 8 1 2 3 4 Ground nut 1 1 1 2 Washer Retaining screw 1 4 1 2 Grommet (Rubber) Housing Operating Fluid Caution 1.
IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 2 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part
SYJ7000-21-1A 1 pc. 0.2 Caution Be Sure to read before handing.
Response time (ms) (0.5 MPa) Type of actuation 52-SY5000 26 or less 22 or less 38 or less 52-SY7000 38 or less 30 or less 56 or less 52-SY9000 50 or less 50 or less 70 or less 2-position single 2-position double 3-position Note 1) According to dynamic performance test JIS B8375-1981. Note 2) Response time when barriers were combined with a valve.
Refer to back page 50 for Safety Instructions and pages 387 to 391 for Precautions on every series.
AV Tightening Torque when Piping Connection thread Applicable torque (Nm) M5 x 0.8 1.5 to 2 1/6 rotation 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 AU Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/4 Rc 1 Rc 1 1/4 Rc 1 1/2 Rc 2 AF Model Connection R AN120 AN110 AN200 AN300 AN400 AN500 AN600 AN700 AN800 AN900 Effective area (mm2) AR Courtesy of Steven Engineering, Inc
48 to 50 1 1 1 2 8 1 4 1 4 1 2 1 8 3 2 1 For details, refer to Best Pneumatics Vol. 5. 4 3 4 1 Exhaust cleaner (Series AMC) 2 1 Provides noise reduction and oil mist recovery functions.
1ab 1a (ZSM1-121) Possible with ISG2 (Equivalent to IP44) Enclosure Set pressure range 0.1 to 0.6 MPa (-X202) Micro-load type available Available indicator light Compliant with ZM ejector 2ab contact type (Option) With light (Refer to Series IS2761.)
(Example) 2000mm lead wire length Cover Groove Pin 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm Lever 6 10 15 20 25 30 50 DC indicator Socket DXT170-71-1 For DC SY114-5LOZ SY100-30-4A-20 For AC SY114-1LOZ SY100-30-1A-20 Connector Hook Lead wire 10 World Wide Support... Europe ENGLAND SMC Pneumatics (U.K.) Ltd.
Type: Block and Plate for Connection, Type: Air Supply / Exhaust End Block Assembly (Tie-Rod Base) SV1000, Number of Inputs/Outputs: -, Connector: -, Mounting Method: DIN rail mounting, Port pipe connection port diameter: Plug, Rated Voltage: -, Specification: Internal Pilot Specifications, Thread standard: -, Dimension: -, Applicable valve: -, Pressure reduction port: -, Option: -
Type: Block and Plate for Connection, Type: Air Supply / Exhaust End Block Assembly (Tie-Rod Base) SV1000, Number of Inputs/Outputs: -, Connector: -, Mounting Method: DIN rail mounting, Port pipe connection port diameter: ø8 single-action pipe fitting, Rated Voltage: -, Specification: Internal Pilot Specifications, Thread standard: -, Dimension: -, Applicable valve: -, Pressure reduction
Type: Block and Plate for Connection, Type: Air Supply / Exhaust End Block Assembly (Tie-Rod Base) SV1000, Number of Inputs/Outputs: -, Connector: -, Mounting Method: DIN rail mounting, Port pipe connection port diameter: ø5/16" single-action pipe fitting, Rated Voltage: -, Specification: Internal Pilot Specifications, Thread standard: -, Dimension: -, Applicable valve: -, Pressure
Model: VQC1000, Wiring: Single Wiring, Port Size: For 4mm One-touch fitting, Check Valve Option: -
Model: VQC1000, Wiring: Double Wiring, Port Size: For 4mm One-touch fitting, Check Valve Option: -
Model: VQC2000, Wiring: Single Wiring, Port Size: For 4mm One-touch fitting, Check Valve Option: -
Model: VQC2000, Wiring: Double Wiring, Port Size: For 4mm One-touch fitting, Check Valve Option: -