SMC Corporation of America
Elite Part Number Search
Search Results "VQZ115-5LO1-N7-PR"

Series: VQZ2000, Configuration: 2 Position Single, Seal Type: Metal Seal, Function: Standard (0.35W DC, AC), Coil Voltage: 24VDC, Lead Wire: L Plug w/o Connector, w/Light & Surge Suppressor, Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 1/4" One-touch Fitting, Thread: -, Foot Bracket: -, CE Compliant: -

Series: VQZ3000, Configuration: 2 Position Single, Seal Type: Metal Seal, Function: High Pressure 0.9W - DC Only, Coil Voltage: 24VDC, Lead Wire: L Plug w/o Connector, w/Light & Surge Suppressor, Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 1/4" One-touch Fitting, Thread: -, Foot Bracket: -, CE Compliant: -

Series: VQZ1000, Configuration: 2 Position Single, Seal Type: Rubber Seal, Function: Standard (0.35W DC, AC), Coil Voltage: 24VDC, Lead Wire: L Plug w/o Connector, w/Light & Surge Suppressor, Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 1/4" One-touch Fitting, Thread: -, Foot Bracket: -, CE Compliant: -

Series: VQZ1000, Configuration: 3 Position Closed Center, Seal Type: Metal Seal, Function: High Pressure 0.9W - DC Only, Coil Voltage: 24VDC, Lead Wire: L Plug w/o Connector, w/Light & Surge Suppressor, Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 1/4" One-touch Fitting, Thread: -, Foot Bracket: -, CE Compliant: -

Function: High Pressure 0.9W, Coil Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Manual Override: Non-locking Push Style, Port Size: 1/4" One-touch Fitting, Model: -, Option: -, CE Compliant: -

Function: External Pilot, Coil Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Manual Override: Non-locking Push Style, Port Size: 1/4" One-touch Fitting, Model: -, Option: -, CE Compliant: -

Series: 2 (VQZ2000), Configuration: 1 (2 Position Single), Seal Type: 1 (Rubber Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector, w/Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: N7 (1/4" One-touch Fitting)

/N.C.), Seal: 1 (Rubber Seal), Function: Standard Type (0.4W), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

/N.O.), Seal: 1 (Rubber Seal), Function: Standard Type (0.4W), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 1 (2 Position Single), Seal: 1 (Rubber Seal), Function: NR (N + R), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 1 (2 Position Single), Seal: 1 (Rubber Seal), Function: B (Quick Response Type (0.95W), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 1 (2 Position Single), Seal: 1 (Rubber Seal), Function: Standard Type (0.4W), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard Type (0.4W), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 1 (2 Position Single), Seal: 1 (Rubber Seal), Function: N (Negative Common), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

/N.O.), Seal: 1 (Rubber Seal), Function: Standard Type (0.4W), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 1 (2 Position Single), Seal: 1 (Rubber Seal), Function: Standard Type (0.4W), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 2 [2 Position Double (Double Solenoid)], Seal: 1 (Rubber Seal), Function: D [2 Position Double (Double Solenoid Specification)], Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 1 (2 Position Single), Seal: 1 (Rubber Seal), Function: N (Negative Common), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

/N.C.), Seal: 1 (Rubber Seal), Function: Standard Type (0.4W), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 1 (2 Position Single), Seal: 0 (Metal Seal), Function: N (Negative Common), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)