SMC Corporation of America
Elite Part Number Search
Search Results "VVEX4-2-5-AN"

" L2 M1 1/4" 5/32" O 1/4" 5/16" L1 N 3/8" 5/16" M2 1/2" 3/8" Note 1) D is maximum diameter.

TABLE 2-1 DIVISION OF DANGER, WARNING, CAUTION, AND NOTE -2-2 TABLE 2-2 MEANING OF A SYMBOLS -2-2 TABLE 2-3 SAFETY INTERLOCK LIST(PART 1) -2-6 TABLE 2-4 SAFETY INTERLOCK LIST(PART 2) -2-6 TABLE 3-1 QUALITY STANDARD FOR WATER(TAP WATER) -3-4 TABLE 5-1 FUNCTION OF COMPONENTS -5-3 TABLE 6-1 SPECIFICATIONS OF HEC006 -6-1 TABLE 6-2 SPECIFICATIONS OF HEC012 -6-2 TABLE 8-1 AVAILABLE MODE IN LEVEL

As a guide, insert bolts in 2 locations for 2-5 stations, 3 locations for 6-10 stations, 4 locations for 11-15 stations, 5 locations for 16-20 stations and 6 locations for 21-24 stations. Caution 2. When using the manifold with DIN rail in an environment where any vibration or impact is applied to it, the DIN rail itself may be broken.

For example, if the product is operated 24 hours per day, the life will be as follows: Data stored every 5 minutes: 5 minutes x 1 million cycles = 5 million minutes = 9.5 years Data stored every 2 minutes: 2 minutes x 1 million cycles = 2 million minutes = 3.8 years Press the or button in function selection mode to display [F10]. Press the button.

and before communication . 2-2 2.2 Communication specification . 2-2 2.3 Contact input signal . 2-5 2.3.1 Setting of contact input signal type and form . 2-5 2.3.2 Run/stopRunStopExternal switch signal . 2-7 2.3.3 External switch signal . 2-8 2.4 Contact output signal . 2-10 2.4.1 Contact output signal 1 to 3 .2-10 2.4.2 Contact output signal 4 to 6 . 2-11 2.5 Analog output signal . 2-14

[Metal seal] 2. Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 1) These valves can be used without lubrication. 2) If a lubricant is used in the system, use class 1 turbine oil (no additives), ISO VG32. For details about lubricant manufacturers brands, refer to the SMC website.

The delay time can be set in the range 0.00 to 60.00 sec. in 0.01 sec. increments. (5) Press the button for 2 seconds or longer to complete the setting.

Step 2 by on the flow-rate characteristics charts on pages 5 and 6.

. 3-7 Chapter 4 Operation/ Shutdown . 4-1 4.1 CHECK POINTS BEFORE OPERATION . 4-1 4.2 OPERATION . 4-1 4.3 STOP . 4-2 4.4 CAUTIONS FOR RE-START . 4-2 4.5 CHECK POINTS BEFORE RESTART. 4-2 4.6 CAUTIONS WHEN THE PRODUCT IS SHUT DOWN FOR AN EXTENDED PERIOD OF TIME . 4-2 Chapter 5 Checks and Maintenance . 5-1 5.1 DAILY INSPECTION . 5-1 5.2 REGULAR MAINTENANCE . 5-2 5.2.1 Clean the dustproof filter

Warning Caution 4 No.VQC5000V-OMU0002 Precautions for 5 Port Solenoid Valve 2 2 2 2 VQC5000 Series Be sure to read before handling. Refer to main text for detailed precautions on every series. Design / Selection 3.

(The selection should allow a sufficient margin because the value calculated by the selection software involves an error with reference to the actual value.) m3max m1max m2max Weight kg MY340 20 30 40 50 Collision deceleration G 1500 N 10 5 4 3 2 1 40 30 20 10 5 4 3 2 1 m3 max m1 max m2 max Weight kg 8-14-11 11 Series MY3A/3B Model Selection 2 Calculation of Guide Load Factor 1.

www.stevenengineering.com I 2.c VALVES VQZ1000/2000/3000 2.84 5 PORT SOLENOID VALVE BASE MOUNTED / PLUG LEAD TYPE VQZ1000/2000/3000 2.87 5 PORT SOLENOID VALVE BODY PORTED / PLUG LEAD TYPE (N)VH 2.90 4/2, 4/3 HAND VALVE (N)VM400 2.91 3/2 MECHANICAL VALVE (N)VM800 2.92 3/2 MECHANICAL VALVE (N)VM1000 2.93 3/2 NORMALLY CLOSED MICRO MECHANICAL VALVE (N)VZM550 2.94 5/2 MECHANICAL VALVE (N)VR2110

-2 Fig. 4-4 Electrical diagram -4-3 Fig. 4-5 Circulating fluid circuit -4-3 Fig. 5-1 HEC002-A -5-1 Fig. 5-2 HEC006-A -5-1 Fig. 5-3 Air Filter -5-2 Fig. 5-4 Top view -5-2 Fig. 5-5 Operation panel-5-3 Fig. 5-6 Display -5-3 Fig. 5-7 Reservoir Cap -5-4 Fig. 6-1 Cooling capacity -6-2 Fig. 6-2 Heating capacity -6-2 Fig. 6-3 Pump capacity -6-3 Fig. 9-1 Alarm indication in the event ERR14 arises

time . 4-2 4.7 Signal output . 4-2 Chapter 5 Checks, Maintenance and Adjustment . 5-1 5.1 Daily inspection . 5-1 5.2 Regular maintenance . 5-2 5.2.1 Maintenance for water-cooled condenser . 5-2 5.2.2 Auto Drain Maintenance . 5-6 5.3 Adjustment . 5-8 5.3.1 Capacity Control Valve . 5-8 5.3.2 Sight glass (for IDF240D-3-W only) . 5-8 IDF190D/240D Series IDX-OM-Y002 Contents Chapter 6 Troubleshooting

Note) Auto shift input time Series PSE 200: 10 [ms] or longer Other series: 5 [ms] or longer Hi Auto shift input time Lo Note) Auto shift input time Series PSE 200: 10 [ms] or longer Other series: 5 [ms] or longer 885 Technical Information Auto shift function 12 2-wire pressure switch connections 13 A 3-wire type switch is a switch that has an output line other than the positive and negative

Please consult with SMC. 2. Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator.

ITV X88 2 0 1 0 S 0 1 2 High-speed response time specifications Model Pressure range 1 2 1000 type 2000 type 1 3 5 0.1 MPa 0.5 MPa 0.9 MPa Pressure display unit 2 3 4 5 MPa kgf/cm2 bar PSI kPa Power supply voltage Input signal 0 1 24 VDC 12 to 15 VDC 0 1 2 3 Current 4 to 20 mA (Sink type) Current 0 to 20 mA (Sink type) Voltage 0 to 5 VDC Voltage 0 to 10 VDC Cable connector type S L N Straight

3 0 1.3 1.06 2.19 3/8-18 1 3/8 2.13 3 3/4 2.48 5 1/4 1 1 1/4 2 3/8 2 5/16 3/4-16 7/8 3/8 3/8 19/32 325 (3.25) 1 5/8 3.9 2 1 1/2 5/8 1 1/4 3/8-24 3 3/4 0 1.57 1.18 2.76 1/2-13 1 5/8 2.59 4 1/4 2.72 6 5/64 1 3/8 1 1/2 2 5/8 2 11/16 1-14 1/2 5/8 5/8 400 (4) 1 3/8 1 5/8 4.7 2 1 1/2 5/8 1 1/4 3/8-24 4 1/2 0 1.57 1.18 3.32 1/2-13 1 5/8 2.59 4 1/4 2.72 6 5/64 2 1/10 2 5/8 2 11/16 1-14 1/2 5/8 5/

ABOUT REINSTALLATION . 3-7 Chapter 4 Operation/ Shutdown . 4-1 4.1 CHECK POINTS BEFORE OPERATION . 4-1 4.2 OPERATION . 4-1 4.3 STOP . 4-2 4.4 CAUTIONS FOR RE-START . 4-2 4.5 CHECK POINTS BEFORE RESTART . 4-2 4.6 CAUTIONS WHEN THE PRODUCT IS SHUT DOWN FOR AN EXTENDED PERIOD OF TIME . 4-2 Chapter 5 Checks and Maintenance . 5-1 5.1 DAILY INSPECTION . 5-1 5.2 REGULAR MAINTENANCE . 5-2 5.2.1

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge temp. 4 High circulating fluid return temp. 5 High circulating