The power supply for control and input, or the input device, is Off. 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 DX E/DX F DY B/DY E/DY F Content Content Content DM E/DM F ST: STatus display LED ST: STatus display LED ST: STatus display LED
URL http://www.smcworld.com -10 V to 10 V -20 mA to 20 mA for 2 hours each in direction X, Y and Z respectively (De-energized) 24 VDC Class2, 2 A 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 0 V to 10 V 0 mA to 20 mA Content Content Content 0 V to 10 V 0 mA to 20 mA 0 V to 10 V 0 mA to 20 mA
Hysteresis 150 L/min Item Default setting System error Panel mount adapter Caution Delay time 0.00 s 3000 L/min Flow range The switch output specification can be selected by pressing or button.
0.510.5 L/min 2.552.5 L/min 5105 L/min 10210 L/min 25525 L/min / 0.1 L/min 0.5 L/min 1.0 L/min 2.0 L/min 5.0 L/min / 09 L / 1 L 3 4 -50 kPa0.5 MPa -50 kPa0.75 MPa 1.0 MPa NPN PNP 3 () 3 80 mA DC30 V(NPN ) NPN1 V (80 mA ) PNP1.5 V (80 mA ) 1 s 1F.S. 2F.S. 5F.S. 0 3 (3 digits) 50 ms 0.1 L/pulse 0.5 L/pulse 1 L/pulse 2 L/pulse 5 L/pulse 5F.S. 3 7 OUT1ON OUT2ON DC1224 V10 () 150
Lead free heat and oil resistant PVC Finished O.D. 6 -66No.LV50***-OMQ0002-G Characteristics Chart Flow characteristics (pressure loss) LFE1 LFE2 0.02 0.02 P r essur r e l oss[ M P a] 0.015 0.015 P r essur e l oss[ M P a] 0.01 0.01 0.005 0.005 0 0 0 5 10 15 20 0 20 40 60 80 100 Fl ow r at e[ L/ m i n] Fl ow r at e[ L/ m i n] LFE3 0.02 0.015 P r essur e l oss[ M P a] 0.01 0.005 0 0 50 100 150
7(69 []) 8 9M12 10DC(-)/+ 65 No.LFE*-OMY0008 100200S/cm 50% () 5S/cm M12 M12 M12 M12 LFE LFE LFE LFE-1 1 1 1-A3 A3 A3 A3 AWG21 0.9 mm PVC 1.7 mm PVC 6 66 No.LFE*-OMY0008 ( ( ( ( ) ) ) ) LFE1 LFE2 0.02 0.02 0.015 0.015 [MPa] [MPa] [MPa] [MPa] [MPa] 0.01 0.01 0.005 0.005 0 0 0 20 40 60 80 100 [L/min] 0 5 10 15 20 [L/min] [L/min] [L/min] LFE3 0.02 0.015 [MPa] 0.01 0.005 0 0 50 100 150
. -25No.LFE*-OMZ0012 Characteristics Chart Flow rate characteristics (pressure loss) LFE1 LFE2 0.02 0.02 Pressure loss [MPa] Pressure loss [MPa] 0.015 0.015 0.01 0.01 0.005 0.005 0 0 0 5 10 15 20 0 20 40 60 80 100 Flow rate [L/min] Flow rate [L/min] LFE3 0.02 Pressure loss [MPa] 0.015 0.01 0.005 0 0 50 100 150 200 Flow rate [L/min] -26No.LFE*-OMZ0012 Straight pipe length (reference value)
Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150
Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150
Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150
Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150
Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150
It is possible to create a multi-connector with mixed tube sizes.Rectangular multi-connector, Connecting tubing: 10, 20, Substantial reduction in mounting space, One-touch connection/disconnection of tubing, MULTI-CONNECTOR, PLUG SIDE, MULTI CONNECTOR, 621, 150 lb
It is possible to create a multi-connector with mixed tube sizes.Rectangular multi-connector, Connecting tubing: 10, 20, Substantial reduction in mounting space, One-touch connection/disconnection of tubing, MULTI-CONNECTOR, SOCKET SIDE, MULTI CONNECTOR, 621, 150 lb
In addition, the LES series is available in an optional symmetric style *.Reduced tact time - 5,000 mm/s¦ max. acceleration, 400 mm/s max. speed , Positioning repeatability: within ¦0.05 mm , Positioning pattern outputs: 64 points , Compact and space saving , Applicable strokes: 50, 75, 100, 150, Electric Slide Table/High Rigidity Type, ELECTRIC ACTUATOR, 2.5 lb
Series: NCDA1 (Standard w/ Magnet), Mounting: X (MP1, Double Rear Clevis), Bore Size: 150 (1 1/2"), Stroke: 0400 (4"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: SF (Short Female, Threaded)
The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.
A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking CLAMP CYLINDER W/LOCK CLKQ, CLK2.
A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking CLAMP CYLINDER W/LOCK CLKQ, CLK2.
A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking CLAMP CYLINDER W/LOCK CLKQ, CLK2.