Stations: 6 Stations, Port Size: 5/32" One-touch Fitting, SI Unit: EtherNet/IP, -COM, Number of Input Blocks: Input Block 6 pcs., Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: Name Plate, Option 2: Built-in Silencer, Direct Exhaust, US Option: -
Stations: 6 Stations, Port Size: 5/32" One-touch Fitting, Wiring Specification: +COM, Lead Wire Length: 5.0m Cable, Option 1: -, Option 2: -, Option 3: -, Option 4: -, Option 5: -, Option 6: -, CE Compliant: -
SI Unit: DeviceNet, Input Block Stations: 63 [6 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: -COM, Stations: 6 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, A, B Port: 5/32" One-touch Fitting, Mounting Method: DIN Rail Mounting, US Option: Preferred US Option for DeviceNet Type
SI Unit: EtherNet/IP, Input Block Stations: 63 [6 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: +COM, Stations: 6 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: 5/32" One-touch Fitting, Mounting Method: DIN Rail Mount w/o DIN Rail, US Option: -
Type: Base for Manifolds, Communication Protocol: EtherNet/IP, EtherCAT Compatible, Output Format: PNP (Negative Common), Type: EX500, 128 Points Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: 32 points (output), Connector: N/A, Mounting Method: Direct mounting, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø8 single-action
Type: Base for Manifolds, Communication Protocol: EtherCAT Compatible, Output Format: PNP (Negative Common), Type: EX260 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: 32 points (output), Connector: M12 Connector, Mounting Method: Direct mounting, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action pipe fitting
Type: Base for Manifolds, Communication Protocol: EtherNet / IP Compatible, Output Format: PNP (Negative Common), Type: EX260 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: 32 points (output), Connector: M12 Connector, Mounting Method: Direct mounting, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action pipe fitting
Type: Base for Manifolds, Communication Protocol: PROFINET Compatible, Output Format: PNP (Negative Common), Type: EX260 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: 32 points (output), Connector: M12 Connector, Mounting Method: Direct mounting, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action pipe fitting
Type: Base for Manifolds, Communication Protocol: PROFIBUS DP Compatible, Output Format: PNP (Negative Common), Type: EX260 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: 32 points (output), Connector: M12 Connector, Mounting Method: Direct mounting, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø12 single-action pipe fitting
CP96, profile tube design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm. The series is available with a single or double rod in 6 bore sizes from ø32 to ø125mm. The air cushion and bumper cushion combination greatly reduces noise at the end of stroke. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life.
CP96, profile tube design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm. The series is available with a single or double rod in 6 bore sizes from ø32 to ø125mm. The air cushion and bumper cushion combination greatly reduces noise at the end of stroke. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life.
Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are light weight in design with a bright and easy to read LED display. The monitor output is available either as analog output or switch output. The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Operation Manual, N, ITV, "REGULATOR, N lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Body Style: Body Ported Stacking Manifold Type, Coil Voltage: 24VDC, Flow Rate: Power Consumption: 0.5W, Operating Press: 0.3MPa, Cv: 0.016, Electrical Entry: Grommet, Port Size: Body Ported, Barb Fitting ø4/ø2.5, Made to Order: Special Lead Wire Length, Lead Wire Length: 1000 mm
Body Size: 1500 L/min, Pressure Range: 0.005~0.1Mpa, Fieldbus: EtherNet/IPâ„¢, Thread: Rc, Port: 1/4", 1000, 2000, Made to Order: Manifold Mounting
Body Size: 1500 L/min, Pressure Range: 0.005 ~0.5Mpa, Fieldbus: EtherNet/IPâ„¢, Thread: Rc, Port: 1/4", 1000, 2000, Made to Order: Manifold Mounting