SMC Corporation of America
Elite Part Number Search
Search Results "CS2F125-75"

Analog voltage 1 to 5 V Analog voltage 1 to 5 V Or IO-Link hub (Commercially available) Process Data Bit offset 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 Item CH11 measured value: 16-bit signed integer Bit offset 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 Measurement data of sensors for 4 channels are combined and cyclically sent as a process data.

(PVQ31, 33) L 03 04 06 08 16 23 40 0.3mm ( for PVQ13) 0.4mm ( for PVQ13) 0.6mm ( for PVQ13) 0.8mm ( for PVQ13) 1.6mm ( for PVQ31, 33) 2.3mm ( for PVQ31, 33) 4.0mm ( for PVQ31, 33) M G Flow rate characteristics PVQ13-5-04 (24VDC type) at 0.45MPa PVQ3-5G-23 (24VDC type) at 0.35MPa 140 8 7 120 6 100 Flow rate (Lit/min) Flow rate (Lit/min) 5 80 4 60 3 40 2 20 1 0 0 30 40 50 60 70 80 75

adjustment bolt With adjustment bolt With adjustment bolt With adjustment bolt With adjustment bolt With adjustment bolt With adjustment bolt Configuration Shock absorber model MY1 W MY1 W Without spacer 0 to 6 6 to 12 12 to 18 0 to 11.5 11.5 to 23 23 to 34.5 0 to 12 12 to 24 24 to 36 0 to 16 16 to 32 32 to 48 0 to 5.6 5.6 to 11.2 11.2 to 16.8 0 to 20 20 to 40 40 to 60 0 to 25 25 to 50 50 to 75

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

spring Pilot Diaphragm Repair Kit SUS304 9 11 KT-AR6 5 KT-AR8 5 KT-AR9 5 Dimensions Model A B C D E F Bracket Dimensions G H J NAR425435 3.15 5.55 1.46 2.64 3.01 0.12 1.83 1.89 3.15 (80) (141) (37) (67) (76.5) (3) (46.5) (48) (80) NAR625635 3.86 5.98 1.57 3.07 3.23 0.28 3.35 2.05 3.54 (98) (151.9) (40) (78) (82) (7) (85) (52) (90) NAR825835 4.96 8.54 2.95 4.33 3.86 0.20 (126) (216.9) (75

Under certain circumstances, the use of an electronic type pressure gauge is recommended. 22 0 0 43.5 58 72.5 87 101.5 Supply pressure (psig) 142 Return to Menu Specialty Regulators NARM Series Regulator for Manifold NARM1000, 2000 Dimensions Dimensions Symbol A B C D E F G H J K M P Q R Model NARM1000 .18 .98 1.34 .83 .71 2.20 .63 .35 .71 .75 2.05 .35 .45 .19 (4.5) (25) (34) (21) (18) (

Please contact SMC for the product usage with a voltage at 75 VDC or more. Standard required by CE mark is different. 3. Since this valve is air return (differential pressure return) type, the valve may not close due to back pressure when the flow on the downstream side is restricted extremely. 4.

Two EPDM 75 durometer O-rings are supplied with each unit. Two O-rings are recommended in case of surface imperfections, damage to an O-ring during assembly, etc. The O-rings must be lubricated with silicone grease during assembly. This not only eases the assembly procedure, it also enhances the sealing characteristics of the O-ring, especially in vacuum applications.

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

Max. operating pressure Note 1) 2R (MPa) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Note 1) Note 2) Min. bending radius 100 15 25 30 50 65 13 20 24 30 40 50 60 Min. bending radius (mm) Note 3) Fixed end Bending value (Reference) 75 12 20 23 40 48 10 15 18 23 30 40 45 40 to +100C, Water: 0 to +70C (No freezing) Nylon 12 Operating temperature

Momentary Energizing Time Wiring When the double solenoid type is used with momentary energizing, the energizing time should be taken as 0.1 second or more (At the supply pressure 50 kPa [75 PSI].) For DIN terminal and terminal block (with light/surge voltage suppressor), the interior wiring is shown below. Please connect with respective poewr terminals.

Coil rated voltage (V) 24, 6, 12, 48 Allowable voltage fluctuation (%) Power consumption (W) [Current mA] 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Note) Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200

DXT170-75-1) SET2 Indicator light Caution Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages 687 to 691 for Pressure Switch Precautions. Set the possible min. pressure for adsorption confirmation. If setting the pressure lower than that, switch becomes ON in case that adsorption is not completely done.

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

.: DXT170-75-1) VQZ Note) Ensure the locking type manual override is unlocked before using.

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

Palmitic acid Triacetin Barium sulfide Diisopropyl keton Isobutyl alcohol Perchlorate Tributoxy ethyl phosphate Beer Dioctyl phthalate Isooctane Perchloroethylene Tributyl phosphate Beet sugar liquors Dioctyl sebacate Isopropyl acetate Petroleum Trichloroethylene Benzaldehyde Dipentene (Limonene) Isopropyl alcohol Phenol Tricresyl phosphate Benzine Diphenyl Isopropyl ether Phosphoric acid (75%

retaining ring Fe 11 Body CAC or Stainless steel 316L equivalent Dimensions Insulated adapter (PPS, FKM, Fe) (Other special options) M5 (Tightening torque: 0.4 to 0.6 Nm) 10-32UNF can be connected. 45 22.5 27 1/8 Pilot port 17 D E OUT IN E 2 x P Port size A C B A Dimensions [mm] Model Port size P A B C D E VXB215A D 3/8 23 55 99.8 88.3 11.5 VXB215B E 1/2 27 65 106.8 90.8 13.5 VXB215C F 3/4 32 75

.: DXT170-75-1) VQZ Note) Ensure the locking type manual override is unlocked before using.

Cylinder Stroke Standard stroke (mm) Manufacturable stroke range 25 50 75 100 Model CEP1B12 1 to 150 CEP1B20 1 to 300 Strokes other than standard strokes are available upon request for special. Consult with SMC separately. 648 A