SMC Corporation of America
Elite Part Number Search
Search Results "21-CJ2B10-75"

Test DRV 1 Start test Safety speed SET 75 - StopSET AX IS. Test DRV 1 Step No. 0 Posn 0.00mm Stop SET 1 Return SET AX IS. Test DRV 1 Step No. 0 Posn 123.45mm Complete(Return) (5-3-4) ON/OFF (5-3-4-1) SET AX IS.

3 port base mounted: VK334 M3 x 26 Round head combination screw M3 x 26 Round head combination screw Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Manifold gasket Manifold gasket Applicable base Applicable base VV3K3-20 21 VV5K3-20 21 VK300-45-1 Sub-plate VV3K3

From back 2 x 2-M8 x 1.25, thread depth 16 14 56 12 (Max. 35) 94 82 43 (body width) 4 2-M10 x 1.0 Adjustment bolt 78 60 8 90 24 86 85 60 80 15 12 (absorber stroke) 2-RB1412 shock absorber M14 x 1.5 2-Rc(PT) 3/8 Cylinder port 129 Note) 244 + Stroke 7 7 134 2-10 through 12 110 48 43 75.5 11.5 21 87 85 65.5 75 55 SMC Body (Support bracket) (MY-S32A (B)) Note) The dimension can be adjusted to

M2 M3 m2 m3 16 20 25 32 40 50 63 16 20 25 32 40 50 63 6.0 3.0 1.0 18 7 2.1 10 5.2 1.7 26 10.4 3 15 9.0 2.4 38 15 4.5 MY1MW 30 15 5.0 57 23 6.6 59 24 8.0 84 33 10 115 38 15 120 48 14 140 60 19 180 72 21 6.0 3.0 2.0 18 7 2.1 10 5.0 3.0 25 10 3 15 8.5 5.0 35 14 4.2 30 14 10 49 21 6 MY1CW MY1B 60 23 20 68 30 8.2 115 35 35 93 42 11.5 MY1H 150 50 50 130 60 16 The above values are the maximum allowable

Bore size Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches Lead wire length (m) Load voltage Auto switch model no.

Bore size Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches Lead wire length (m) Load voltage Auto switch model no.

7 NBR Valve retainer seal #7 * Since ther is a possibility of improper operation, contact SMC regarding the replacement of seals. 4.4-9 Series CE1 Dimensions 12, 20 Both ends tapped CE1B Bore size Stroke (mm) A B C D E G H I K L M Bore (mm) 12 20 Standard stroke 25, 50, 75, 100, 125, 150 94 M5 X 0.8 16 5.2 25 15.5 69 15 6 25 42.5 25, 50, 75, 100, 125, 150, 175, 200 106 78 15.5 10 36 53.5

a) .250 \-24 0.50 .624 .621 0.25 0.86 0.38 it-l6 .251 .zfi 0.75 0.25 o.34 It.oo o.75 o.62 o.12 # 1 8 o.75 1-?

Magnet: None, Mounting: Basic Style, Bore Size: 10mm, Stroke: 75mm, Cushion: -, Head Cover Port: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

CY36 Consult with SMC in case a bracket with weight exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000 CY315 Note 1) According to the dead weight deflection in the figure on the right, provide clearance so that the cylinder does not touch the mounting surface or the load, etc., and is able

28 29 25 27 34 18 X 21 14 1 R P 3.5 40 4 26 40.5 26 34 4 48.7 10 2-M4 x 0.7 2-4.5 54.2 55.5 (3.6) 54.2 (Mounting screw) (For mounting) 8 1 (P, A, R port) 0.8 54.5 P R 1.8 (Breathing hole) 1.8 (Breathing hole) 20 16 14.5 With filter (80 mesh) 12 With filter (80 mesh) 23 15 , 8 1 4 1 48 (P, A, R port) 5-4-8

1 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 Compact yet provides a large flow capacity Various manifold piping directions V100 Output port: Manifold set-up allowing 360 rotation of 2 (A) entry direction (in 90 increments) Body width 18 mm SY Type 20 and 21 SYJ Available in vacuum applications (101.2 kPa) VK VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco

Confirm there is no rattle on the pulley cover. 21 Electric Actuator/Maintenance Guide 6 Be sure to read before handling. Motor Mounting X Y Z Applicable model LG-240ZMotor assembly instructions Motor Assembly Procedure 1. Remove the four bolts on the top cover. 4. Mount the motor on the mount block. At this time, be sure to take measures against loosening.

Oooosite side of 02 2 stations 20 20 stations Same side as A port Port size I B3T lone touch frttina fors/32'tube B7T lone touch fittino for 1/4" tube Body ported / Type 21 (A pon: top porting) NW3KF3-21-@-OOT Applicable valves NVKF3330 OOO -M5 NVKF333O OOO -o1T .

Port Direct Operated Poppet Solenoid Valve SeriesVKF300 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 Series VKF300 Compact with large flow rate Body width 18mm Cv0.25 (Standard: Base mounted type) Cv0.20 (Standard: Body ported type) Various manifold piping directions Output port: Manifold set-up allowing 360 rotation of 2(A) entry direction (in 90 increments) Types 20 and 21

Initial Test Drive .14 6.2.1 Start up the Setup software (MR Configurator2TM) . 15 6.2.2 System Settings . 16 6.2.3 Model Selection . 16 6.2.4 Driver ON LINE Check . 17 6.2.5 Help Function . 17 6.3 Parameter setting (Driver side) .18 6.3.1 Change of parameter block . 19 6.3.2 Reading parameters . 20 6.3.3 Parameter setting method . 20 6.3.4 The recommended parameters for each actuator . 21

No.1 No.2 No.3 Setting the Station Address Station Address S1 S2 No.1 03H 0 3 04H 0 4 No. 2 05H 0 5 No. 3 21 - 4. Parameter setting (Driver side) The setting is a necessary parameter. Please optionally set it. Please refer to "LECYU manual" for a detailed parameter.

cover (Part no.: ZS-46-D) 47.8 50.8 33.5 34.5 20.2 11 R4.5 R4.5 33.5 34.5 21 42.4 Panel thickness 0.5 to 7 Power supply/output connection lead wire (Part no.: ZS-46-5L) Sensor connector (Part no.: ZS-28-CA-4) 5 12.35 Pin no.

Under certain circumstances, the use of an electronic type pressure gauge is recommended. 22 0 0 43.5 58 72.5 87 101.5 Supply pressure (psig) 142 Return to Menu Specialty Regulators NARM Series Regulator for Manifold NARM1000, 2000 Dimensions Dimensions Symbol A B C D E F G H J K M P Q R Model NARM1000 .18 .98 1.34 .83 .71 2.20 .63 .35 .71 .75 2.05 .35 .45 .19 (4.5) (25) (34) (21) (18) (