-02 ASP ASN AQ ASV AK VCHC ASS ASR ASQ Component Parts No.
VQZ (A) 2 (A) 2 VZ 3 (R) 1 (P) 3 (R) 1 (P) VS VFN r e w q r e w q N.O. N.O. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Component Parts No.
(35) 33 (11) 2-4.5Mounting holes DIN rail clamp screw (5.5) Grommet (G) (7.5) 24 (2.5) U side 02: Rc(PT)1/4 n Manual override 5 A A A A 4 2 2 2 2 (L4) (L3) L2 L1 3 2 P=19 1 21 6 Stations D side 1.8 (C6, C8) 17.5 3.5 20.5 10.5 300 75.5 (Lead wire) Cover dia 1.6 Cross section 0.34mm2 (C10) (02) 63 56 (11) PE port R 3 1 P (24) 9 2-Rc(PT)1/4 P(SUP) port 2-Rc(PT)1/4 R(EXH) port 21 10 41 DIN terminal
, d e t e r i o r a t i o n o f a c c u r a c y, a n d breakage of parts.)
pilot port) 44 62 9 9 91 44 62 Station number 50.5 59 2-Rc 1/8 (External pilot port) R4.5 R4.5 50.5 9 9 U side entry (LU) U side D side D side U side n 15 X X n X 12 12 12 12 8 B 2 A 4 B 2 A 4 8 Manual override 7 B 2 A 4 SMC SMC SMC SMC SMC SMC SMC B 2 A 4 7 A B A B A B A B A B A A A B A B A B A B A B A A SMC SMC SMC SMC SMC SMC SMC B B B A A A A A A A B A B 2 A 4 6 B 2 A 4 6 B B A A A A
): 0.18kg Series EVS1-01/1-02 How to Order FG S EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 NPTF Passage symbol Port size (A) 4 (B) 2 Size 02 Size 01 Piping specifications Symbol Nil A01 A02 FG Without sub-plate 1 (P) 5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B) 2 Single Nil
www.stevenengineering.com I 6.11 VACUUM VACUUM PADS SERIES ZP H O W T O O R D E R ZPT P A D V E R T I C A L T Y P E W I T H O U T B U F F E R ZPT V A C U U M E N T R Y ( A L S O M O U N T I N G T H R E A D D I A) P A D D I A M E T E R S Y M B O L T H R E A D D I A M E T E R 2~ 8 10~ 16 20~ 32 40 50 02 2 04 4 06 6 08 8 10 10 13 13 16 16 20 20 25 25 32 32 40 40 50 50 P A D M AT E R I A L Male
5 Port Air Operated Valve Series VFA3000 How to Order Thread type (Including pilot port) Nil Rc G NPT NPTF Port size (P, A, B port) F N T 01 02 1 8 1 4 R1, R2 port are 1/8. Option F Foot bracket Mounting bracket are supplied, but unattached.
CE-compliant Valve mounting direction Stations R port Nil Pilot valve is opposite the A port side. 02 2 stations A A M5 x 0.8 Nil R port P R Q CE-compliant : : A A M5 x 0.8 A port M3 x 0.5 P port M5 x 0.8 Pilot valve is on the A port side. 20 S 20 stations P port M5 x 0.8 A port M3 x 0.5 Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of
(0.2 to 2.0 MPa) VBA11A-02 AR425 to 935 ARX 1/4" AMR ARM ARP VBA20A-03 VBA22A-03 IR-A IR IRV 3/8" VEX SRH SRP VBA42A-04 VBA43A-04 (0.2 to 1.6 MPa) VBA40A-04 SRF ITV 1/2" IC ITVH ITVX Air Tank VBAT Series PVQ P.1022 VY1 Perfect fit with a booster regulator VBA VBAT VBA VBAT This is an air tank to which a booster regulator can be connected compactly.
How to Order Sub-plate and Base Gasket Body size 22 42 VEX VEX VEX1 2 9 A VEX4 2A 1 A Port size Thread type Port size Thread type Symbol Port size A 1/8 B 1/4 Symbol Thread type Nil Rc F G N NPT T NPTF Symbol Port size A 1/4 B 3/8 C 1/2 Symbol Thread type Nil Rc F G N NPT T NPTF Sub-plate Base gasket VEX1 11 2 VEX4 4 Options/Part Number Description Part number VEX312-01 02 VEX322-01 02 VEX33202
A-q A-w A-e A-r A-t A-y A-u A-!1 A-y A-u A-!2 A-!
Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Max.
G A S K E T C O N S T R U C T I O N A g a s k e t m a d e o f s t a i n l e s s s h e e t c o v e r e d w i t h l a m i n a t e d N B R o n b o t h s i d e s i s s e a t e d o n t h e chamfer of a female thread to materialize a perfect sealing construction irrespective of the difference in thread diameters due to the difference in the types of female threads, variation in tolerance, difference
in Parentheses MECHANICAL VALVES DIMENSIONS Series NVM NVM121-N01-02 131-N01-02 NVMl21-N01-01 131-N01-01 f,-rgl1gtlr ?.
EX: NVM121-N01-01S NVM131-01-01 NVM131-01-35 NVMl51-01-35 NVMl21-01-02 NVM13t-01-02 NVM120-N01-00 130-N01-00 F.O.F.'lbs.
SYJA 2(A) 2(A) Standard VZA (P)1 3(R) (P)1 3(R) i VFA 2(A) 2(A) 2(A) 3(R) VFRA o For vacuum (P)1 3(R) (P)1 3(R) VPA4 SYJA X VZA 1(P) VTA For vacuum u y t r e w q VGA VPA VPA VPA3 i 2(A) 3(R) o X Component Parts No.
VVEX2-2-5-02 VEX1233-G VEX1-17 4 pieces 1 piece Set Pressure Characteristics (Air operated type) Set Pressure Characteristics (Manual handle type) A port pressure (MPa) A port pressure (MPa) Signal port PA Pressure (MPa) Handle rotation (Cycles) 14-6-5 6 Series VEX130 3 Flow Characteristics P port pressure: 1 MPa VEX1A33, VEX1B33-01 VEX1130 3, VEX1230 3-02 VEX1330 3-03 A port pressure (MPa
(1.8) 14.8 (0.8) 36 (2) 15.3 (0.85) 02 03 VFA5144 2 position single : 0.51 02 03 04: 0.56 34.2 (1.9) 34.2 (1.9) 33 (1.8) 36 (2) 45 (2.5) 52 (2.9) 02 03 04 1 8 3 8 1 2 1 4 , , : 0.52 02 03 04: 0.57 1 8 45 (2.5) 52 (2.9) VFA5244 2 position double 02 03 04 3 8 1 2 1 4 , , Body ported : 0.66 02 03 04: 0.71 VFA5344 -X1 3 position closed center 1 8 34 (1.9) 38 (2.1) 02 03 04 JIS Symbol 3 8 1 2
If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.