Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 40mm, Port Thread Type: TN (NPT), Stroke: 40mm, Body Option: M (Rod End Male Threads), Locking Direction: B (Retraction Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 40mm, Port Thread Type: TN (NPT), Stroke: 40mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: None, Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector),
Mounting: Double Clevis, Bore Size: 40mm, Stroke: 40mm, Option: Rod End Male Thread, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: Light/Surge Voltage
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: None, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: G [Grommet
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical
Mounting: D (Double Clevis), Bore Size: 40mm, Stroke: 40mm, Option: M (Rod End Male Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector With Lead Wire), Surge Voltage Suppressor: Z
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: 40mm, Port Thread Type: NPT, Stroke: 40mm, Body Option: Rod End Male Threads, Locking Direction: Retraction Locking, By-Pass Piping: None (Emergency Stop), Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface, Version: None, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: G [Grommet (Lead Wire Length
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface, Version: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: G [Grommet
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface, Version: None, Auto Switch: w/o Auto Switch w/Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion
The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion
The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion
C55 double acting, air operated cylinders were designed to meet a broad range of automation machine applications. The C55 series achieves outstanding load performance due to its unique rubber bumpers, piston wear ring, and rod bushing. Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm,
C55 double acting, air operated cylinders were designed to meet a broad range of automation machine applications. The C55 series achieves outstanding load performance due to its unique rubber bumpers, piston wear ring, and rod bushing. Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm,
Production and packaging applications involving food and beverages often need specialized equipment to meet the strict hygiene standards required in these industry sectors. SMC, the world leader in pneumatic technology, has developed the HY series to meet these requirements. All the models in the HY series are particularly suitable for application in the "non-food" or "splash" zones of