With barb fitting With drain guide Metal bowl Metal bowl with level gauge Model B B 107 160 214 251 255 B B AC10A AC20A AC30A AC40A 208 246 249 234 272 275 209 247 250 AC40A-06 6 F.R.L.
Optional specifications Note) With barb fitting With drain guide Metal bowl Metal bowl with level gauge Model B B B B AC20D AC30D AC40D AC40D-06 160 209 208 214 234 247 246 251 272 250 249 255 275 14-2-23 24 F.R.L.
With barb fitting With drain guide Metal bowl Metal bowl with level gauge Model B B 107 160 214 251 255 U 38 45 45 B B AC10A AC20A AC30A AC40A 234 272 272 208 246 249 209 247 250 AC40A-06 6 F.R.L.
MGPS50 50 11 12 A 13 B 14 1 2 3 4 5 50 80 7 8 9 A 10 B 15 16 6 17 NBR 18 NBR 19 A NBR 20 B NBR / (mm) 50 MGP50-PS 19 18 17 80 MG80-PS 20 17 20 GR-S-010(10g 18 18. 18-1.
Refer to page 378 for minimum stroke with auto switch. 32 is for B-series rod size only. CH2 H B B 50 100 CH D2 H B B 50 100 M9BW With Auto Switch With auto switch (built-in magnet) Port and cushion valve positions Refer to page 359.
(2) Conversion formula from the measurement value to the process data: (PD) = (Pr b) / a Pr: Measurement value and directive value PD: Measurement value (process data) a: Inclination b: Intercept [Inclination and intercept to the unit specification] Applicable products Unit Range Inclination a Intercept b 4 L/min 0.004 0 16 L/min 0.016 0 L/min 40 L/min 0.04 0 100 L/min 0.1 0 250 L/min 0.25
SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.
2 18.5 12 12 e d i s U e d i s D Stations 1 2 3 4 5 6 7 8 n One-touch fitting [3(R), 1(P) port] Applicable tubing O.D.: 10 10 Lead wire length: L0, 0.6 m L1, 1.5 m L2, 3.0 m For top ported R 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 62.1 41.7 25.7 39.4 (58) 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 20.9 P 1 P=17.5 48.8 30 7.5 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4 : 6 : 8 L n Formula
phase J B C D A A COM COM COM B 12 VDC GND F.G.
HA AT Series AME, AMF ID 250 CA A AME AMF AMG AFF Body size AM 150 250 350 450 550 650 850 Misc. 14-20-59 Series AFF-CA, AM-CA Dimensions Series AFF, AM, AMD, AMH, AMG Size: AFF2B to 37B, AM150 to 650 (B) (B) (B) (C) (A) (A) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Description Material AS800 AS900 y u i JIS B 2401 P-7 JIS B 2401 P-7 AQ NBR O-ring u O-ring O-ring Spring NBR NBR Stainless steel JIS B 2401 P-12 JIS B 2401 G-50 14115 JIS B 2401 P-16 JIS B 2401 G-65 14124 JIS B 2401 P-48 JIS B 2401 P-38 NBR O-ring ASV i AK ASS Dimensions: AS420/500/600 Dimensions: AS800/900 ASR ASF 2-Port size 2-Port size Dimensions Dimensions L1 L2 L4 Min.
38 35 42 40.5 A 33 32.5 34 31 38 36.5 49.5 48.5 A B A B A B A B 20 25 32 40 50 63 80 100 B 24 (32) 24.5 (32.5) 25 (33) 27 (36) 32 (44) 33.5 (45.5) B 14.5 (22.5) 15 (23) 15.5 (23.5) 17.5 (26.5) 22.5 (34.5) 24 (36) 29 (43) 30 (44) B 20 (28) 20.5 (28.5) 21 (29) 23 (32) 28 (40) 29.5 (41.5) B 16 (24) 16.5 (24.5) 17 (25) 19 (28) 24 (36) 25.5 (37.5) 30.5 (44.5) 31.5 (45.5) Hs 27.5 30 33.5
X77 A B X78 Symbol Port size Accessory Port size Rc 3/8 1/2 3/4 Accessory Symbol Nil None Bracket 03 04 06 B Symbol Element seal material Note 1) Symbol Element category Element seal material Non-asbestos Fluororesin NBR FKM Material Bronze Stainless steel Polypropylene Glass fiber Cotton Cotton Stainless steel 304/Epoxy Stainless steel 316 Element type A Note 2) B S T G H P M L Sintered
X77 A B X78 Symbol Port size Accessory Port size Rc 3/8 1/2 3/4 Accessory Symbol Nil None Bracket 03 04 06 B Symbol Element seal material Note 1) Symbol Element category Element seal material Non-asbestos Fluororesin NBR FKM Material Bronze Stainless steel Polypropylene Glass fiber Cotton Cotton Stainless steel 304/Epoxy Stainless steel 316 Element type A Note 2) B S T G H P M L Sintered
0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure (kPa
Condition: Pressure 0.5MPa, Load 50%, Piping length 5m Effective area mm 2(Cv ) Cylinder speed (mm/s) 50 63 80 100 125 140 Bore size (mm) 160 180 200 250 300 Port size Rc(PT) 40 250 25(1.4) VEX312 -01, 02 500 750 02 ( 1 4) 60(3.3) 250 500 750 250 500 750 500 750 1000 500 750 1000 250 500 750 250 500 750 VEX332 -02, 03, 04 Body ported Base mounted 03 (3 8) 160(8.9) VEX350 -04, 06, 10 06 (3
B A Auto switch mounting bracket A-A B-B Dust seal band type Seal band holder roller specification C No.
For IITV00-n Total weight (g) Stations (n) x 100 + 130 (Weight of end block A, B assembly) + Weight (g) of DIN rail Note 2) Specifications other than the following are optional.
Outside Inside the controller 10k (a) 1k (a) IN0