E Round pressure gauge G Panel mount (with set nut) P JIS Symbol 0.02 to 0.2MPa setting 1 N Non-relieving type R Flow direction: Right Left Display units for product name plate and pressure gauge: PSI, F.
Applicable bore A 0.51 D C 1/4-28 UNF B 0.16 JM-025 0.44 3/4", 7/8" JM-03 0.50 0.19 5/16-24 UNF 0.50 1 1/16" JM-045 0.69 0.79 0.26 7/16-20 UNF 1 1/4", 1 1/2" JM-04 0.56 3/8-24 UNF 0.65 0.23 1 1/4", 1 1/2" (Non-rotating) JM-05 0.75 1/2-20 UNF 0.32 0.87 2" 6-14-20 21 Series NCM Mounting Bracket Accessory Material: Rolled steel P dia.
500 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature Circulating fluid temperature 50Hz 60Hz The cooling capacity will be reduced by 300W when option: T and MT are selected.
5 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature Circulating fluid temperature 60Hz 50Hz Fig. 9-5 Heating capacity(HRS060-A-20-(BJM)) 9.5.2 HRS060-W-20-(BJM) 2000 2000 Ambient Ambient temperatur temperatur Heating capacityW Heating capacityW 1500 e e 1500 40 32 25 20 5 40 32 25 20 5 1000 1000 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating
550 600 500 10 Built-in shock absorber CY1F 15 750 25 1200 Model Piping direction Centralized piping on the right side CY1F Centralized piping on the left side
Refer to P.18 for assembling method. NPN output M8 8 Pin connector (Plug) PIN No.
, Auto Switches: M9BW, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: N/A, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Axial foot type, Rod Boot: None, Custom-made Specifications: None, Stroke adjustment symbol: -
: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Type of Mount Support: U-Shaped Clevis Type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9BW, Lead Wire Length(m
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9BW, Lead Wire Length(m): 0.5, The number
Lead Wire Lead wires with a connector indication Lead wire length indication Part No. of Lead Wires with Connectors (Applicable only for connector type) D-M9BW (Example) L Model Lead wire length D-LC05 0.5 m Symbol Lead wire length D-LC30 3 m Length 0.5 m 1 m 3 m 5 m None 0.5 m 1 m 0.5 m 1 m 0.5 m 1 m 3 m Solid state 2) Reed 3) Tolerance 15 mm 30 mm 90 mm 150 mm 15 mm 30 mm 15 mm 30 mm
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches