0 e o !6 Component Parts Note Hard anodized Hard anodized No. Cylinder tube Rod cover Piston rod Guide Table Piston Magnet Steel ball Bumper Bumper Description Material Aluminum alloy Aluminum alloy Stainless steel The main parts are made of stainless steel.
Description Note Side plate q w e r t y u i o !
Magnet: D (Built-in), Series: J2, Mounting: E (Double-side Bossed), Bore Size: 16mm, Stroke: 175mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.), Auto Switch Mounting Type: B (Band Mounting)
Bore: 25mm, Thread: Rc, Piping: Standard Type, Stroke: 150mm, Adjustment Bolt: H (Left, Right: High Load Shock Absorber, Adjustment Bolt), End Lock: E (Right End), Auto Switch: A96V--Reed, DC Volt, LED, Vertical
Bore: 25mm, Thread: Rc, Piping: Standard Type, Stroke: 150mm, Adjustment Bolt: H (Left, Right: High Load Shock Absorber, Adjustment Bolt), End Lock: E (Right End), Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connection: L (3m)
Magnet: D (Built-in), Mounting: E (Double End Mount), Bore Size: 106 (1 1/16"), Stroke: 0800 (8"), Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 3 pcs.
AC DC Auto switch model Lead wire length (m) 0.5 (Nil) Load voltage Indicator light Wiring (Output) Special function Type Electrical entry Pre-wire connector Applicable load 3 (L) 5 (Z) Perpendicular In-line IC circuit 3-wire A96V A96 5 V Reed switch Solid state switch Grommet (NPN equivalent) Yes Yes 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV
Magnet: D (Built-in), Mounting: E (Front screw clearance hole), Bore Size: 056 (9/16"), Stroke: 050 (1/2"), Body Option: CM (Rubber Bumper & Male Rod End), Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
25~650 1150 900 63 25~800 25~650 1150 900 80 25~750 25~600 1100 900 100 25~750 25~600 1100 850 4-2 CEU2 NPN P PNP 15 4-3 CE1-R 5 5m 10 10m C 15 15m 20 20m A B CD E F G () 16 5. 5-1 17 18 5-2 19 5-3 20 6. 6-1 1 3 4 7 5 2 6 8 9 10 11 6-2 1 11 10 9 2 3 4 5 6 7 8 12 AC DC LCD 21 7. 7-1 7-1-1 1 ISO VG32 060 1m 7-1-2 M4 DIN [050] [25%85%] [1055Hz 0.75mmXYZ 2 ] 7-2 7-2
North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics Inc. (Milwaukee) 16850 W. Victor Road New Berlin, WI 53151 Tel: (262) 827-0080 FAX: (262) 827-0092 SMC Pneumatics Inc. (Atlanta) 1440 Lakes Parkway, Suite 600 Lawrenceville, GA 30043 Tel: (770) 624-1940 FAX: (770) 624-1943 SMC Pneumatics Inc.
North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics Inc. (Milwaukee) 16850 W. Victor Road New Berlin, WI 53151 Tel: (262) 827-0080 FAX: (262) 827-0092 SMC Pneumatics Inc. (Atlanta) 1440 Lakes Parkway, Suite 600 Lawrenceville, GA 30043 Tel: (770) 624-1940 FAX: (770) 624-1943 SMC Pneumatics Inc.
F C D E Setting the Indicator Needles Move the indicator needles with your fingers. If it is done with a small screw driver, etc., take care not to bend the indicator needles or scratch the gauge dial. There are 2 green indicator needles, to be set at the upper and lower limits of the pressure range.
8.88 800 (8") 1.375 1-14 1.63 2.000 1.530 1.000 8.50 3/4 NPT .75 5.13 1.31 1.32 3.25 4.25 3.000 1.63 9.00 Note: Pivot and cotter pins are included.
level gauge Without drain cock Drain cock thread piping With drain guide AF800 AF900 409 489 440.5 520.5 393.5 473.5 410 490 406.5 486.5 Push button B (With auto-drain) Model A B C D N.O N.C E AF800 AF900 150 200 410 490 33 46 140 170 439 519 440 520 200 260 Precautions Be sure to read before handling.
Refer to pages 16-14-3 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. q w Locking nut t Wiring e Warning 1. Light assembly for 24 VDC has 2 terminals and polarity. One is + for red load wire and the other is for black load wire.
Refer to pages 17-6-3 to 17-6-10 for Safety Instructions and Solenoid Valve Precautions. 4 ' C ' C 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) ) D G C D, T S S L, Z 3 ) E E 3 0 ( 2 17-3-69 2 The VX series will be revised shortly. Series VXH Construction/Dimensions Material C3771 Note No.
North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) North Amerlcan BranOh Oflaces For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics Inc. (Atlanta) SMC Pneumatics lnc. (Cleveland) SMC Pneumatics Inc. (L.A.) SMC Pneumdtics Inc.
North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) North Amerlcan BranOh Oflaces For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics Inc. (Atlanta) SMC Pneumatics lnc. (Cleveland) SMC Pneumatics Inc. (L.A.) SMC Pneumdtics Inc.
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 1100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]