SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2F80-250-D-M9BASBPC"

Switch operating position (ON) Hysteresis Switch reset position (OFF) Unit: mm Auto switch model Air gripper D-Y7 W N B D-Y59A B D-Y69A B D-Y7 WV N B D-Y7BA 0.8 0.6 0.7 0.5 MHL2-10Dl Note)Use a watchmakers screwdriver with a grip diameter of 5 to 6mm to tighten the auto switch set screw. Use a tightening torque of 0.05 to 0.1 Nm.

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

O-ring Port plug Body Ported Base Mounted Blanking plug (For One-touch fittings) KJP-02 A L Dimensions [mm] Applicable fitting size d Model A L D Weight [g] 2 KJP-02 8.2 17 3 0.1 3.2 KQ2P-23 16 31.5 5 1 4 KQ2P-04 16 32 6 1 23 KQ2P-04 D Silencer (For manifold EXH port) Body Ported Base Mounted Silencer is installed in the EXH port.

RESET SVON <> <> <>(M24V) (01-145) D RESET SVON <> <> <> (01-146) D RESET SVON <> 67 - <> <>(DC24V) D RESET SVON (01-147) <> <> <> (01-148) D RESET SVON <> <> (01-149) D RESET SVON <> <> Communicati on error. (01-150) D RESET SVON <> (01-192) E <> <> <> ON(SVON ON) (01-193) E <>ONSVON ON <> (01-194) E <> 68 - <> <> (1-195) E <> (01-196) E <> <>EEPROM

A Input/Output specifications 22 30 62 NPN open collector 2 output + Analog output Bracket D NPN open collector 2 output + Auto shift input Refer to the dimensions for the difference between brackets A and D. D PNP open collector 2 output + Analog output 70 PNP open collector 2 output + Auto shift input Option Note) Auto shift input is used for the auto shift function.

Dimensions LLCA--C Stations 4-Mounting hole for W Y A K D L3 L2 L1 (Max.

Flat finger [3] 4 x MM thread depth L Thread for mounting attachment K J A A D G B D B K J F C S W O (mm) Weight (g) F G Open Closed 2 2.5 3 4 L MM J K D C B Model A W MHZ2-10D3 1), 2) 11221122112211220 -0.05 0 -0.05 0 -0.05 0 -0.05 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 +0.025 0 +0.025 0 +0.025 0 +0.030 0 +2.2 0 +2.2 0 +2.3 0 +2.5 0 60 125 250 450 5 6 8 10 M2.5 x 0.45 M3 x 0.5 M4 x 0.7

Note) Note) For the special voltages, please consult with SMC. 4-14-11 Body Ported 12 Series VQZ100/200/300 How to Order Manifold: VQZ200/300 VV3QZ 2 2 08 C D Series Option 2 3 VQZ200 VQZ300 Nil None DIN rail mounting style (With DIN rail in standard length) DIN rail mounting style (Without DIN rail ) D DO Note) Note) Order DIN rail separately.

SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT A One-touch fitting d Part No. A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 D VP Color: White VG VP L DIN rail AXT100-DR-l 12.5 (Pitch) 5.25 7.5 VQ Enter suffix number into l from the table below.

Use a D-class ground connection (ground with a resistance of less than 100). The cross sectional area of the grounding cable shall be 2 mm2 or more. The Grounding point should be as near as possible to the controller. Keep the grounding cable as short as possible.

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 100mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,