Mounting: Through-hole, Standard, Bore Size: 40mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: with Boss on Head End, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Temperature Resistant Option: XB6 [Heat Resistant (-10 to 150°C)]
Magnet: Built-in, Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 16mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Rear Boss Mount, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: F7PV--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control
Magnet: Built-in, Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Rear Boss Mount, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: F7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type
Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 12mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: Double Acting, Rod End: Round Bar w/Female Rod End, Direct Mount Switch Groove: None, Mounting Bolt: Shipped Together Only for Mounting B, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Bore Size: 10mm, Action: Double Acting, Dust Cover: Fluoro Rubber (FKM), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 10mm, Action: Double Acting, Body Option: Basic Style, Dust Cover: F(Fluoro Rubber (FKM)), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Made-to-Order: -
Bore Size: 10mm, Action: Double Acting, Body Option: Basic Style, Dust Cover: F(Fluoro Rubber (FKM)), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Dust Cover Caulking
Bore Size: 10mm, Action: Double Acting, Body Option: Basic Style, Dust Cover: F(Fluoro Rubber (FKM)), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -, Made-to-Order: -
Bore Size: 10mm, Dust Cover Type: F [Fluororubber (FKM)], Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15.2, Closed Dimension L2(mm): 11.2, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 9.8, Gripping Force (Open Side at 0.5 Mpa)(N): 17, Environment, Applications: Standard / Dust Resistant / Drip-Proof,
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15.2, Closed Dimension L2(mm): 11.2, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 9.8, Gripping Force (Open Side at 0.5 Mpa)(N): 17, Environment, Applications: Standard / Dust Resistant / Drip-Proof,
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15.2, Closed Dimension L2(mm): 11.2, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 9.8, Gripping Force (Open Side at 0.5 Mpa)(N): 17, Environment, Applications: Standard / Dust Resistant / Drip-Proof,
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15.2, Closed Dimension L2(mm): 11.2, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 9.8, Gripping Force (Open Side at 0.5 Mpa)(N): 17, Environment, Applications: Standard / Dust Resistant / Drip-Proof,
Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Rear Boss Mount, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical, Lead Wire or Prewired Connector: 0.5m (Or
Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Rear Boss Mount, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number:
Part Number Description: XC4-ROD SCRAPER Product Line: A Product Line Description: ACTUATOR This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number
Part Number Description: SCRAPER MGP-XC4 Product Line: A Product Line Description: ACTUATOR Family Code: 481 Family Description: MGP COMPACT GUIDE CYLINDER Class Code: S1 Part Code: 2 Reference Code: J This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number
When cylinder is operated in dusty areas, use a strong scraper (-XC4) type. 3. Do not use in environments or locations where the equipment is exposed to cleaning solvent, etc. and oil film on rod may be washed away. Seals may break due to insufficient lubrication, causing air leakage. 13 - 4. Do not store cylinders in humid places.