SMC Corporation of America
Elite Part Number Search
Search Results "CS2T140TN-300"

Collision speed V = 1.4Va Ea = KEmax Workpiece mounting coefficient K: Fig. (3) Max. allowable kinetic energy Emax: Table (1) Kinetic energy (E) Allowable kinetic energy (Ea) ) Correction factor (Reference values) V = 1.4 x 300 = 420 Ea = 1 0.11 = 0.11 Can be used based on E = 0.088 Ea = 0.11 Load Factor 3 3-1 Load factor of load weight Wa = KWmax Workpiece mounting coefficient K: Fig

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Up to 300 Up to 100 Up to 500 Up to 100 Up to 300 Up to 500 Maximum speed (mm/s) (2) 50 (7) 100 (5) 50 (4) 100 (8) 200 (9) 100 (11) 50 (10) (1) 200 (12) 200 (6) Load eccentricity (l mm) (3) Selection graph L: Overhang (the distance from the cylinder

CS1N180A-PS CS1N200A-PS CS1N250A-PS CS1N300A-PS Seal kit includes a grease pack (125 to 160: 40 g, 180 and 200: 50 g, 250 and 300: 60 g). Order with the following part number when only the grease pack is needed.

LMV10 81023-2A-1 to 4 Note 1) LMV20 Flexible nozzle assembly Copper piping nozzle assembly O-ring 1 1 2 2 81023-31A-1 to 4 Note 1) 123116-2 3 FKM Note 1) Numbers indicate nozzle lengths. 1: 200 mm, 2: 250 mm, 3: 300 mm, 4: 350 mm 1066 LMU100/200 Series Mist Spray Unit Magnet Holder: LMH Series AL800 AL900 How to Order Dimensions ALF ALT LMH 0 1 ALD Magnet holder ALB 2 x M4 x 0.7 Air blow

m 400 1 m 350 Displayed value 300 5 m 250 200 150 100 50 0 0.5 0.4 0.3 0.2 0.1 0 Actual distance [mm] Nozzle Shape Internal Circuit and Wiring Example ISA3-N NPN (1 output) The nozzle shape must be similar to Fig. 1.

800 1250 3100 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 20 25/32 40 50/63 5 Semi-standard/Thread nominal size JC20-8-100 JC25-10-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 0.5 0.5 0.5 0.75 0.75 0.75 1 1 300 800 800 1250 1250 1250 3100 3100 M8 x 1 M10 x 1.5 M10 x 1 M12 x 1.25 M12 x 1.5 M12 x 1.75 M16 x 1.5 M16 x 2 20 25 32 32/40 40 32/40 50 50/63 5 How to

air supply Pressure in the tank New New 20 9.2 4 AV2000-A Current model 30 13.1 7.4 Up to 50% shorter 40 19.2 12.2 50 (Port size 3/4) 34.8 22.6 AV2000-A New New Fill time 50 (Port size 1") 41.3 24.4 Current model For 1(P) R 2(A) Improved adjustability at low speed air supply Needle Valve Flow Rate Characteristics Inlet pressure: 0.5 MPa 400 Air flow rate [L/min (ANR)] 350 Current model 300

400 500 100 200 300 400 500 100 200 300 400 500 Elimination ratio (%) Elimination ratio (%) Elimination ratio (%) 75 70 60 50 40 30 20 10 0 1 5 10 50 30 100 1 5 10 50 100 Flow-back count Flow-back count Flow-back count Explanation of graph Explanation of graph Example: Elimination ratio and concentration after using the FHM-100 for one hour under the following conditions.

Operating time 20 s 30 s HRZ 10 s Voltage HRZD 5 s Min. 2 s HRW 1 s 0.5 s dV dt HECR = Voltage increase ratio 0.2 s 0.1 s dV HEC 0.05 s 0.02 s Time HEB 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 dt HED Current (% for chiller main breaker volume) < For option B [With earth leakage breaker]> 3.

Applicable for the hightemperature environments Increased air flow capacity IDFB60 IDFB70 IDFB90 IDFB80 50 10 New Current model IDFB Series 49 IDFB Series 9 48 IDFB75E IDFB55E 47 IDFB22E IDFB37E 8 46 Max. 113F (45C) Max. 104F (40C) Ambient temperature Dew point [C] Dew point [F] 45 7 44 43 6 42 41 5 Max. 149F (65C) Max. 122F (50C) 40 Inlet air temperature 39 4 38 3 37 0 200 100 400 500 300

Series 12-REA Sine rodless cylinder 25, 32, 40, 50, 63 How to Order Clean series 12 Special treatment on sliding part Bore size (mm) 12 REA 25 300 Cylinder stroke (mm) Type Port type Symbol Nil TN TF Rc NPT G Model Bore size (mm) Maximum manufacturable stroke (mm) Model Port size Standard stroke (mm) Lubrication Rc1/8 NPT1/8 G1/8 Rc1/4 NPT1/4 G1/4 12-REA25 12-REA32 25 32 40 200, 250, 300

Sensors (R) (P) 7.4 3 (13) M plug connector (M) L plug connector: 10-VQD1151-L-M5 M plug connector: 10-VQD1151-M-M5 5 5 5.5 2(B) 4(A) Direct manual override Lead wire length 300 mm 27 Indicator light 17.6 11.2 3 3(R) 9 0.3 3.8 10.9 3.5 5.5 9.1 2 x mounting hole 33.5 28.5 37 38 1(P) 1(P) 5.5 12 4-M5 x 0.8 13 L plug connector (L) (P, A, B, R port) 49 50.5 M plug connector (M) 598 4 Port Direct

400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) ARP Pressure Characteristics (Representative Values) IR-A IR Conditions: Inlet pressure 0.7 MPa Outlet pressure 0.2 MPa Flow rate Q = 20 L/min (ANR) 0.30 IRV Outlet pressure (MPa) 0.25 Set point VEX 0.20 SRH SRP 0.15 SRF 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8

20 40 60 80 100 0 50 100 150 Flow rate L/min (ANR) Flow rate L/min (ANR) Condition: Inlet pressure 0.7 MPa ARM11AA1-310-1 (One-touch fittings: IN 8, OUT 6) Condition: Inlet pressure 0.5 MPa ARM11AA1-310 (One-touch fittings: IN 8, OUT 6) 0.35 0.7 0.6 0.30 Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0.00 0 0 50 100 150 200 0 50 100 150 200 250 300

0 0 50 100 200 250 150 300 VBA VBAT Flow rate L/min (ANR) Flow rate L/min (ANR) AP100 Pressure Characteristics (Representative Value) Outlet pressure 0.2 MPa Flow rate 20 L/min (ANR) Condition: Inlet pressure 0.7 MPa Condition: Inlet pressure 0.5 MPa Outlet pressure 0.2 MPa Flow rate 20 L/min (ANR) ARM5BA-306 ARM5BA-306-1 0.30 0.30 Outlet pressure (MPa) Outlet pressure (MPa) 0.25 0.25 0.20

Mode automatically changes to Monitor mode when there is no movement of the mouse for 300 seconds on the I/O Configurator. Logged in from Administrator mode, but the I/O setting or pairing setting cannot be performed. 2 Log in again from Administrator mode. Delete the password by entering the master key.

Mode automatically changes to Monitor mode when there is no movement of the mouse for 300 seconds on the I/O Configurator. Logged in from Administrator mode, but the I/O setting or pairing setting cannot be performed. 2 Log in again from Administrator mode. Delete the password by entering the master key.

. : The mode is automatically changed to monitor mode unless a mouse operation is 6 Monitor mode/ Administrator mode performed within 300 seconds in Administrator mode. -12No.EX-OMV0017 3.1.1. Login to administrator mode Password is necessary to login to the Administrator mode. The Initial password is "admin".

Mode automatically changes to Monitor mode when there is no movement of the mouse for 300 seconds on the I/O Configurator. Logged in from Administrator mode, but the I/O setting or pairing setting cannot be performed. 2 Log in again from Administrator mode. Delete the password by entering the master key.

-3165-000FL ZS-28-C-5 37104-2206-000FL -12No.PS-OMG0001CN-H PSE31() PSE30() 2 3 1 (DC(+)) (LINE(+)) (DC(+)) 2 3 (DC(-)) (DC(-)) 4 (OUT15 V) (LINE(-)) (OUT420 mA) A A A -13No.PS-OMG0001CN-H DC+5 OUT1 4 OUT2 3 2 DC-1 M3 mm 0.30.35 Nm PSE3T 3 PSE31T 2 -14No.PS-OMG0001CN-H ZS-28-A PSE30(T) PSE31(T) NPN 2 NPN 2 Max.30 V80 mA 1 V Max.30 V80 mA 1V :15 V 1 k :420 mA 300