SMC Corporation of America
Elite Part Number Search
Search Results "ISA3-GFP-1B-L1"

Control unit: With control unit (supply port: left side), Number of stations: 2 stations, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Regulator: Round type pressure gauge with regulator

Control unit: With control unit (supply port: left side), Number of stations: 4 stations, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Regulator: Round type pressure gauge with regulator

Control unit: With control unit (supply port: left side), Number of stations: 6 stations, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: NPN 1 output, Unit specification for pressure values: SI unit fixed, Regulator: Round type pressure gauge with regulator (AR-A), Cable

Control unit: With control unit (supply port: left side), Number of stations: 1 station, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Regulator: Round type pressure gauge with regulator

Control unit: With control unit (supply port: left side), Number of stations: 2 stations, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Regulator: Round type pressure gauge with regulator

Control unit: With control unit (supply port: left side), Number of stations: 2 stations, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Regulator: Round type pressure gauge with regulator

Control unit: With control unit (supply port: left side), Number of stations: Triple, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Regulator: Round type pressure gauge with regulator (

Control unit: With control unit (supply port: left side), Number of stations: 4 stations, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Regulator: Round type pressure gauge with regulator

Control unit: With control unit (supply port: left side), Number of stations: 1 station, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Regulator: Round type pressure gauge with regulator (AR-A), Cable

Control unit: With control unit (supply port: left side), Number of stations: 1 station, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Regulator: Round type pressure gauge with regulator (AR-A), Cable

Control unit: With control unit (supply port: left side), Number of stations: 2 stations, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Regulator: Round type pressure gauge with regulator (AR-A), Cable

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply Port:

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 0.4 MPa)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 0.4 MPa)

-F: [20], ISA3-G: [50], ISA3-H: [50] ISA3-F: [3], ISA3-G: [20], ISA3-H: [20] Display Thank you for purchasing an SMC ISA3-#L series Gap Checker.

The ISA series is a non-contact style air catch sensor for applications requiring confirmation of work present for machining operations. Due to the construction of the sensor, fluctuations in the supply pressure does not influence operations. The ISA series is IP66 rated and is dust proof and drip proof. Air catch sensor, Operating pressure: 0.05 to 0.2MPa, Enclosure IP66, Port size: 1/8

F 0 Unit selection 1 [ PA] kPa Connector Switch point Hysteresis Display colour ISA3-F: [ 20], ISA3-G: [ 50], ISA3-H: [ 50] OUT1 setting Bracket mounting hole ISA3-F: [ 3], ISA3-G: [ 20], ISA3-H: [ 20] F 1 [ SoG] Green when ON, Orange when OFF out2: [ Ewin] OUT port side pressure detection window comparator mode Output mode Thank you for purchasing an SMC ISA3 series Gap Checker.

ZSE10 ISE10 Reducing setting labor Minimizing risk of mistakes in setting ISE70 Copy Copy ZSE80 ISE80 PS ISA3 ISA2 ISE35 Master sensor 1 unit Slave side 2 units 10 units PSE 3-step setting 3-step setting IS ISG 1 2 3 ZSM1 Push Push Push Push Completion of setting Adjust to the set-value by the or button. Added vacuum range.

The ISA3-L is an IO-Link compatible version of SMC's ISA3 digital gap checker.  A gap checker uses air pressure to verify the presence and proximity of a workpiece.  Applications include confirmation of raw material placement before machining or other fabrication operations, or the correct seating of a component into a jig or fixture to trigger the next assembly sequence. 

The ISA3-L is an IO-Link compatible version of SMC's ISA3 digital gap checker.  A gap checker uses air pressure to verify the presence and proximity of a workpiece.  Applications include confirmation of raw material placement before machining or other fabrication operations, or the correct seating of a component into a jig or fixture to trigger the next assembly sequence.