Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -
Designation Description 1 SI24 V +24 V for SI unit operation 2 SV24 V +24 V for solenoid valve 3 SI0 V 0 V for SI unit operation 4 SV0 V 0 V for solenoid valve : Recommended mating M12 5-pin socket, part no. EX500-AP00and PCA-1401804. (Refer to page 40) The M12 connector cable has two types, SPEEDCON compatible and non-compatible.
Designation Description 1 SV24 V +24 V for solenoid valve 2 SV0 V 0 V for solenoid valve 3 SI24 V +24 V for SI unit operation 4 SI0 V 0 V for SI unit operation 5 Unused The M12 connector cable has two types, SPEEDCON compatible and non-compatible.
] 0.7 40 50 [Outlet port: 50 Hz] 0.6 [Outlet port: 50 Hz] 40 30 0.5 0.4 30 20 0.3 20 0.2 10 [Return port] 10 [Return port] 0.1 0 0 0 0 10 20 30 40 Lifting height (m) Pressure (MPa) 0 10 20 30 40 Lifting height (m) Pressure (MPa) Circulating fluid flow (l/min) Circulating fluid flow (l/min) HRZ001-H/002-H HRZ004-H/008-H HRZ002-W/008-W 0.8 0.9 50 0.8 0.7 [Outlet port: 60 Hz] 40 [Outlet port
Power supply is AC200V single phase (Note 4) Malfunction RA1 OFF ON MC MC SK EMG stop switch Driver Servo amplifier Servo motor MC (Note 7) MCCB CNP1 1-phase 200 V AC to 240 V AC (Note 11) L1 CNP3 (Note 6) U U L2 Motor V V L3 M [1] W NW P3 (Note 1) (Note 10) P4 CNP2 P+ [2] (Note 2) C [3] D (Note 11) (Note 3) Encoder CN2 Encoder L11 cable L21 (Note 8) Main circuit power supply CN3 EM2 24 V
Application 2 port 3 port 2 port 3 port VM120-01-00 VM121-01-00 VM130-01-00 VM131-01-00 VM122-M5-00 VM123-M5-00 VM132-M5-00 VM133-M5-00 Basic Mechanical operation Manual operation Roller lever VM121-01-01 VM121-01-01S VM131-01-01 VM131-01-01S VM123-M5-01 VM123-M5-01S VM133-M5-01 VM133-M5-01S Polyacetal roller Hard steel roller VM121-01-02 VM121-01-02S VM131-01-02 VM131-01-02S VM123-M5-
An example of when the SI unit station number is set to 01 is shown below.
Lead wire (m) Load voltage Indicator light Pre-wire connector Wiring (Output) Special function Type Electrical entry Data Applicable load Auto switch model 3 (L) 5 (Z) None (N) 0.5 (Nil) AC DC 3-wire (NPN equivalent) IC circuit C76 5 V Reed switch Solid state switch Grommet B54 C73 C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF 100 V, 200 V 100 V 12 V Yes Yes Relay, PLC 24 V 2-
(mm) Connection thread R Model Effective area (mm 2) Weight (g) A L2 M L1 1 8 4 L04-01 33 10 21.8 30.9 15 3.5 32.7 10 14 10 1 4 1 8 L04-02 L06-01 40 36 14 10 34.9 30.9 34.7 33.8 Applicable tubing 1 4 3 8 1 8 6 L06-02 L06-03 L08-01 43 55 46 12 10 14 35.8 37.5 36 9 21.8 34.9 36.9 31.9 16 14 17 12 1 4 3 8 1 4 L08-02 L08-03 L10-02 52 61 68 8 14 12 17 38 39.7 40.7 19 23.3 35.9 37.9 36.9 16 14
/ sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS BUS Fig. 11-3 Block diagram of the EX245-DX1 74 No.EX##-OMY0004 12.
Table 11-1 EX245-DX1 (W x L x H) mm 54 x 120 x 61 280g , PBT 24 V DC 1.6 V 50 mA 8 x M125 A code 2 / US1 30V /1 0.5A /1 2 A 1 16 PNP ON 11 to 30 V OFF -3 to 5 V 1.5mA ON Typ. 4.5 mA 24VDC 71 No.EX##-OMY0006CN 11.3. /SI IP65M12 M12,5 , Table 11-2 EX245-DX1 (TOP View) 1 24 V 2 2 DI ( n+1) 3 5 1 3 0 V (US1) 4 DI (n) 4 5 FE/ 11.4.
Graph 1 10 500st 600st 700st 400st 4 5 300st 3 200st 2 Load movement time: t(s) 100st [Example] 1 Example) 0.4 0.5 0.3 0.2 300 0.1 V' 100 200 1000 400 500 Maximum speed: V(mm/s) V W Step 2 Find the cylinder bore size.
Designation Description 1 FG Function earth 2 0 V 0 V for solenoid valve 3 24 V +24 V for solenoid valve 4 SI0 V for SI unit operation 5 SI+ +24 V for SI unit operation The power supply connector included as an accessory can be used to supply the power. Applicable wire for the power supply connector is AWG24 to AWG16 (0.2 to 1.5 mm2).
Standard 10 in. (0.25 m) 7 in. (0.18 m) 5 in. (0.13 m) Code Gauge port (Inlete) No code MPA No code M V X Pressure gauge 1) Code psig/bar unit MPa unit 2) Pressure gauge unit MPa or psig/bar selectable.
AR-OMT0015 PRODUCT NAME REGULATOR MODEL/ Series AR20K-(F,N)01 (F,N)02(B,E,G,H,M)(-1,N,R,Y,Z)-B AR25K-(F,N)02 (F,N)03(B,E,G,H,M)(-1,N,R,Y,Z)-B AR30K-(F,N)02 (F,N)03(B,E,G,H,M)(-1,N,R,Y,Z)-B AR40K-(F,N)02 (F,N)04(B,E,G,H,M)(-1,N,R,Y,Z)-B AR40K-(F,N)06(B,E,G,H,M)(-1,N,R,Y,Z)-B AR50K-(F,N)06 (F,N)10(B,E,G,M)(-1,N,R,Y,Z)-B AR60K-(F,N)10(B,E,G,M)(-1,N,R,Y,Z)-B Contents PAGE 1.
Formula (2) V Q din : Fluid flow velocity (m/s) : Fluid volume (l/min) : Effective inside diameter of piping (mm) Effective inside diameter of piping Fluid flow velocity V = Q 1 ___ 60 Rubber hose 5m/s Formula (3) din x 10__ 4 Steel piping 4.5m/s 1/2" (12.7 ) rubber hose 5/8" (15.3) rubber hose 3/4" (19) rubber hose 12 rubber hose 15 10 13 17 3/8" (9.5) rubber hose 30 9 8 20 7 6 1/4" (6.3
motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W) Connect the motor ground terminal to the driver ground terminal.
Mount switches in locations where there is no vibration greater than 98 m/s2, or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.