5 Spring pin 40 CKZT-T040 Top cover kits Note 1) T = TURCK, P = P&F Note 2) Please specify the opening angle by the code in Table 1. 195 B Series CKZT Construction (50, 63, 80) t !3 !4 A-A A A u !0 o q e !2 y i w r !1 Table 1 Replaceable Kits List Contents Kit no. Bore size (mm) Description Code Opening angle 30 H e Switch holder y Proximity switch u Parallel pin i Sheet gasket !
P/A warrants that for 18 months or 1800 service miles*, whichever occurs first from date of purchase, it will replace or make adjustment at P/As option, of any defective cylinder sold if the cylinder product is returned with P/As prior written consent, transportation prepaid by the original buyer, and received by P/A at its place of business within the warranty period.
mounting range GB A F K BN Rc(PT) P TB AL 2-TDe8 (pin O.D.)
P Polyolefin P White, Black Red, Blue Yellow, Green 20 P P 100 TPS P P P Soft Polyolefin P P 1ft = 0.3048 1in = 25.4mm 3 Series KP Clean One-Touch Fittings Recommended Applicable Tubing Polyolefin: Series TPH Soft polyolefin: Series TPS Tubing material 4, 6, 8, 10, 12 Tubing O.D.
P Polyolefin P White, Black Red, Blue Yellow, Green 20 P P 100 TPS P P P Soft Polyolefin P P 1ft = 0.3048 1in = 25.4mm 3 Series KP Clean One-Touch Fittings Recommended Applicable Tubing Polyolefin: Series TPH Soft polyolefin: Series TPS Tubing material 4, 6, 8, 10, 12 Tubing O.D.
A Adjustment amount by adjustment bolt A Adjustment amount by adjustment bolt A Adjustment amount by adjustment bolt B Adjustment amount by adjustment bolt B Adjustment amount by adjustment bolt B 90 Rotation 90 Rotation 90 Rotation 11-9-13 14 Series MSQ Construction o i t !
If you change by these by mistake, it may cause the amplifier to not work properly. 5.3.2 Change of parameter block If you read the parameters of the driver to the software, please do the read operation. From the View menu bar "parameter (A)" please click on the "parameter setting (P)". "Parameter Settings" screen will display. Please click on the Read".
If you change by these by mistake, it may cause the amplifier to not work properly. 5.3.2 Change of parameter block If you read the parameters of the driver to the software, please do the read operation. From the View menu bar "parameter (A)" please click on the "parameter setting (P)". "Parameter Settings" screen will display. Please click on the Read".
Turn another 90 from the position where tightening is felt by hand.
2 Dimensions p. 2 M Vertical Vacuum Inlet, With Adapter How to Order p. 3 Dimensions p. 3 M Vertical Vacuum Inlet, With Buffer How to Order p. 6 Dimensions p. 6 Construction p. 9 Parts Structure p. 10 Mounting Adapter Part Nos. p. 11 Buffer Assembly Part Nos. p. 12 1 Vacuum Pad 20, 25, 35, 50 Pad diameter How to Order ZP3P 20 PTSF Pad unit Pad diameter Symbol Pad diameter 20 20 25 25 35
R C R C (44) G1/2 E A H 2-P Port size B (S) E G1/2 2-M Thread depth N D A H B 2-P Port size 2-M Thread depth N D L L K K N.O.
Transfer speed acceleration set range 0.49 to 4.90 m/s 2 (By selection. Please refer to the table below.)
(Hexagon socket head taper plug) 2-P (Hexagon socket head taper plug) 2-P 2-P (Hexagon socket head taper plug) 1 1 NE PP QQ XXSS RR SS H TT UU PH RW VV UU G A N T-slot for body mounting Z + stroke (mm) P M5 x 0.8 Rc 1/8 Rc 1/4 Model MY2H16G MY2H25G MY2H40G MM M4 x 0.7 M5 x 0.8 M6 x 1 L 80 110.8 180 LD 3.4 5.5 9 LB 50.4 71.7 80.3 LA 70 100 158 J M3 x 0.5 M5 x 0.8 M6 x 1 H 28 37 58 GB 17 19.5
222 CC-Link p. 223 DeviceNet p. 224 PROFIBUS DP p. 225 Communication Cable p. 226 Field-wireable Communication Connector p. 228 Terminating Resistor p. 228 Fieldbus Related Accessories M8/M12 Connector PCA/EX9/EX500 Series Power Supply Cable/Connector EX600 Series p. 229 EX500 Series p. 231 EX260 Series p. 233 EX250 Series p. 235 Accessory Between the Sensor/Switch and the Input
Plug cap P DBacklash in the table at the center position Caution P 1. Backlash in the table in the rotating direction can be controlled by adjusting the center position properly. However, backlash (about 0.1) may occur as the rotation speed increases. If this causes any problems during operation, readjust the center position. Plug cap 299
7 P 8 Press key Press key Anal ogue out put t ype Sw i t ch out put t ype i s di spl ayed i s di spl ayed Press key Press key i s di spl ayed i s di spl ayed Press key Press key Change t he val ue by usi ng t he and Set gai n by usi ng t he and keys.
7 P 8 Press key Press key Anal ogue out put t ype Sw i t ch out put t ype i s di spl ayed i s di spl ayed Press key Press key i s di spl ayed i s di spl ayed Press key Press key Change t he val ue by usi ng t he and Set gai n by usi ng t he and keys.
Refer to p.0-39 through 0-46 for Safety Instructions, actuator precautions and auto switch precautions. With Non-rotating Rod (Double Acting: Single Rod) Adjustment Warning Operating Precautions Caution q Do not open the cushion valve above the stopper.
Contact P/A regarding the bowl assembly supply for PSI and F unit specifications.
How to Rotate the Relief Valve Body (20, 25, 32, 40) Caution The relief adjusting screw can be placed in any direction by rotating the relief valve body by following the steps given below. Procedure 1. Verify that there is no residual pressure in the cylinder. Then, loosen the mounting bracket (such as foot, flange, etc.). 2.