SMC Corporation of America
Elite Part Number Search
Search Results "KR-10C1"

Please contact us for the latest version.sales@ocaire.com, FITTING, CONNECTORS, KR FLAME RESIST FITTINGS, HJ, KR 8MM, 0.02816 lb

Please contact us for the latest version.sales@ocaire.com, FITTING, CONNECTORS, KR FLAME RESIST FITTINGS, HG, KR 8MM, .03058 lb

Please contact us for the latest version.sales@ocaire.com, FITTING, CONNECTORS, KR FLAME RESIST FITTINGS, HB, KR 8MM, 0.06798 lb

Please contact us for the latest version.sales@ocaire.com, FITTING, CONNECTORS, KR FLAME RESIST FITTINGS, JK, KR 10MM, 0.0902 lb

Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.

Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.

Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.

Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.

Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.

Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.

Please contact us for the latest version.sales@ocaire.com KR FLAME RESIST FITTINGS. FITTING, MALE RUN TEE. CONNECTORS. KR 8MM. .06880 lb. HK.

Bore Size: 10mm, Action: Single Acting N.C., Finger Position: Standard-Side Tapped, Body Option: Basic, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Grease for Food

Bore Size: 10mm, Action: Single Acting N.C., Finger Position: Standard-Side Tapped, Body Option: Basic, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Made-to-Order: -

Bore Size: 10mm, Action: C (Single Acting N.C.), Finger Position: 1 (Standard-Side Tapped), Body Option: Basic, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Bore Size: 10mm, Action: C (Single Acting N.C.), Finger Position: 1 (Standard-Side Tapped), Body Option: Basic, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: X79 (Grease for Food)

Series: 3 (VQZ3000), Configuration: 3 (3 Position Closed Center), Seal Type: 0 (Metal Seal), Function: KR (High Pressure 0.9W - DC Only, External Pilot), Coil Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire, Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 02 (Rc1/4), Thread: T (NPTF)

Description RLQ40 RLQ50 RLQ63 Compact Cylinder with Air Cushion and Lock PT elbow Restrictor PT tee 32, 40: AS2200-(N, F)01-S 50, 63: AS2200-(N, F)02-S 32, 40: KRL06-01SW2 50, 63: KRL06-02SW2 TRB0604W KR-06C 2 Metal speed controller 5 2 Male elbow By-pass tubing Spatter cover 6 1 2 7 8 9-12-18 19 Series RLQ Compact Cylinder with Air Cushion and Lock Accessory Bracket Dimensions Single knuckle

In such a place, use of flame resistant fittings (KR/KRM series) and flame resistant tubing (TRS/TRB series) are recommended. 7. Do not use in an environment where the product is directly exposed to cutting oil, lubricant, coolant oil, etc. Please contact SMC if using for an environment exposed to cutting oil, lubricant or coolant oil, etc. 8.

KR KA KQG2 KG 2. Do not use in an environment where it will be exposed to water. Contact with water will cause outflow of the lubricating oil used in the ball bearings, and adversely affect rotating performance and equipment lifespan. 3. Fluorine based grease is used on the rotating portions.