(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF .
(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF.
(SCFM) FLOW AIR 3/32 *OIL FLOW (GPM) 4.0 200 1/16 3/32 3.0 150 1/16 3/64 100 2.0 3/64 1/32 1/32 50 1.0 0 3000 2000 1000 0 0 1000 2000 3000 0 (PSIG) PRESS . INLET PRESS . (PSI) *S.G. = .85 DROP OUTLET PRESS . = " O" PSI COAST PNEUMATICS 8055 E. CRYSTAL DRIVE, ANAHEIM, CA 92807 (714) 921-2255 WWW.COASTPNEUMATICS.COM SERIES 50 EW (5 WATTS AC & DC) MINIATURE HAZARDOUS LOCATION VALVES!
The vertical scale shows the load on the cylinder and is in English tons (1 ton = 2000 lbs.) If the rod and and front end of the cylinder barrel are rigidly supported, then a smaller rod will be sufficient; use the column that is 1/2 the length of the actual piston rod.
lOO (4(00) ./ --.63 --675 (3000) / I 050 -225 (IOOO) 4SO (2000) I 0 14.5 (01) 29 (0.2) 43.5 (O.3) 58 (0.0) 72.5 (0.5) PSI (MPa) Retaining lorce is the capability that can retain a Slatic load with no vlbrallOn or impact after locking. Therefore. when used at near the upper limIt, the following guide will be helpful.
Arm length L A Arm length L A Table 1 Table 1 A Model A Model CKZ3N50 CKZ3N63 CKZ3T50 CKZ3T63 5 10 Series CKZ3N Series CKZ3T 10 10 50 63 Arm length L: 150 mm Arm length L: 200 mm 3000 3000 Peak clamping force position 2500 2500 Peak clamping force position 0.7 MPa 2000 2000 Clamping force (N) Clamping force (N) 0.5 MPa 0.7 MPa 1500 1500 1000 1000 0.5 MPa 0.3 MPa 0.3 MPa 500 500 0 0 0 0.5
Note 3) It describes the grade of compressed air quality based on ISO8573-1: 1991 and JIS B 8392-1: 2000. (Refer to table on top in following page.) Mist Separator Series AM Heatless Dryer Series ID Micro Mist Separator Series AMD Application without refrigerated air dryer (Series IDF/IDU) on main line.
Flow Characteristics Air pressure 0.7 MPa (Example) To get pressure drop at 0.3 MPa of air pressure, 2000 l/min (ANR) of air flow, and model HAA22, use P = 0.0007 MPa from the table and convert P1 to 0.3 MPa.
(Example) Inlet air temperature: 100C, Cooling water temperature: 20C, Cooling water flow: 17 l/min Air flow: 2000 l/min (ANR), Air pressure: 0.7 MPa, Model: HAW22-14 Outlet air temperature at above conditions Use outlet air temperature of 37C from outlet air temperature table. At this time correction factor line becomes A .
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and deenergized states to the axis and right angle directions of the main valve and armature. (Value in the initial stage.) Note 2) At the rated voltage.
D1 20 30 40 50 10 5 -X Transfer speed: (m/min) 20Data Bore Size 32 to 100/MGPM32 to 100 (Slide bearing) MGPM32 to 100 (Slide bearing) m m 2000 l 50 mm l 50 mm 100 1000 80 Weight of transferred object: m (kg) 63 500 400 50 300 40 200 When selecting a model with a longer l dimension, be sure to choose a bore size which is sufficiently large. 32 100 Caution Caution on handling Note 1)
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Screw lead LC1-1(Either T-nuts or T-brackets for mounting) LC1-1-1000 (Controller connector) LC1-1-2000 (Controller connector) (Refer to page 85.) F H L 6mm 10mm 20mm Note) The following options are necessary for operating and setting the controller.
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. The test was performed in both an energized and deenergized state in the axial direction and at a right angle to both the main valve and the armature. (Values at the initial period) 4 Only applicable to the power-saving circuit specification.
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz. The test was performed in both an axial direction and a perpendicular direction to the lead screw. (The test was performed with the actuator in the initial state.) 5 Indicates the max. power during operation (including the controller).
EX600-ZT1 y Communication Cable with Connector/Communication Connector Cable with M12 RJ-45 connector EX9-AC 020 EN-PSRJ (Plug/RJ-45 connector) 14.8 Cable length (L) M12 RJ-45 6.4 010 1000 mm 020 2000 mm 030 3000 mm 050 5000 mm 100 10 mm (47.3) (44) L Cable core wire colors 1 2 1 2 3 4 5 6 7 8 Terminal no. Terminal no.
Proceed with caution. 2000 mm or more 400 mm or more 800 mm or more 800 mm or more 800 mm or more Ventilation HRL -A -20 3. If it is impossible to exhaust heat from the installation area indoors, or when the installation area is conditioned, provide a duct for heat exhaustion to the air outlet port of this product for ventilation.
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 Handling Warning 15. In locations where strong impacts or vibrations occur 16.
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 Handling Warning Thoroughly read the Operation Manual.
(Default settings) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature.