SMC Corporation of America
Elite Part Number Search
Search Results "MDBF63-250Z-A93"

Magnet: Built-in Magnet, Mounting: Front Flange, Bore: 63mm, Stroke: 50mm, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Bore: 63mm, Port Thread: Rc, Stroke: 75mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: W (Double Knuckle Joint), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Magnet: Built-in Magnet, Mounting: Rod Flange, Bore: 63mm, Port Thread: Rc, Stroke: 75mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: Double Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in Magnet, Mounting: Rod Flange, Bore: 63mm, Port Thread: Rc, Stroke: 200mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: Double Knuckle Joint, Auto Switch: P3DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 0.3m Cord Length, M12-4 Pin Connector, 3 & 4 Out, Number: -

Magnet: Built-in Magnet, Mounting: Rod Flange, Bore: 63mm, Port Thread: Rc, Stroke: 150mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: Double Knuckle Joint, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 0.3m Cord Length, M12-4 Pin Connector, 3 & 4 Out, Number: -

Magnet: D (Built-in Magnet), Mounting: F (Front Flange), Bore: 63mm, Stroke: 50mm, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

A93V A93 V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

Note 4) Figures in ( ) in the table W are D-A93.

-X168 (Example) MY2H40G-599L-A93-XB10 Symbol Symbol 2 Long Stroke -XB11 4 Copper-free 20Available with long strokes exceeding the standard strokes.

Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, AUTO-SW, ACTUATOR, MB TIE-ROD CYLINDER, PE, 63MM MB DBL-ACT AUTO-SW, 6.63390 lb

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. *2 1 m type lead wire is only applicable to D-A93. * Solid state auto switches marked with v are produced upon receipt of order. * Do not indicate suffix N for no lead wire on the D-A3A/A44A/G39A/K39A models. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM

D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .

Please consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with p are produced upon receipt of order.

D-M9/M/9W/M9A Less than 20 stroke Note 2) Less than 55 stroke Note 2) D-A90/A93 Less than 50 stroke Note 2) Note 2) Minimum stroke for auto switch mounting in types other than those mentioned in Note 1. 152 Auto Switch Mounting CJ2Y Series Operating Range Auto Switch Mounting Brackets/Part No.

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.