(g) n: Stations W = 30n + 50 W = 37n + 63 W = 61n + 101 W = 79n + 127 W = 100n + 151 Note 1) For more than 10 stations (more than 5 stations in case of 10-SS5Y7), supply pressure to P port on both sides and exhaust from EA/EB port on both sides.
FGDE Seal kit w, r, y, !3, !6: 1 pc. each FGDT FGDF u, o, !1, !2, !3, !4, !5, !6, !7 : 1 pc. each Note) Only the FGD-CA003 and CA005 includes !8 element guide in the set.
70 4 104 40 7 7 32 38 Rc 1/8 Rc 1/8 62 60 13 125 M8 x 1.25 M12 x 1.75 depth 21 115 11 82.5 4 115 45 8 8 38 47 67 75 14 150 M8 x 1.25 WH W X Y U W T V Z Bore size (mm) 20 25 32 40 30 23 30 50 112 146 182 16 53 30 25 37 60 132 167 199 20 63 25 28.5 37 60 132 167 202 20 63 20 33 44 70 25 162 73 210 227 Without Rear Plate Stroke range (mm) Long Stroke Bore size (mm) 20 25 32 40 Bore size (mm
70 4 104 Rc 1/8 Rc 1/8 62 7 7 40 125 60 32 M8 x 1.25 13 38 M12 x 1.75 depth 21 115 11 82.5 4 115 67 8 8 45 150 75 38 M8 x 1.25 14 47 WH W X Y T U V W Z Bore size (mm) 20 25 32 40 30 23 30 112 146 182 16 53 50 30 25 37 132 167 199 20 63 60 25 28.5 37 132 167 202 60 20 63 20 33 44 162 210 227 25 73 70 Without Rear Plate Stroke range (mm) Long Stroke Bore size (mm) 20 25 32 40 Bore size (mm
LVQ LQ Tightening torque for piping LVN Body class Torque (Nm) 2 3 4 5 6 1.5 to 2.0 TI/ TIL 3.0 to 3.5 7.5 to 9.0 PA 11.0 to 13.0 5.5 to 6.0 PAX PB 17-5-75 14 Series LVQ Construction Double acting type Basic type N.C. type N.O. type PB PB q q q PA PA e e e A B SMC A B SMC w r t A B A B A B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (
Calculation ZX ZR : Lifting force (N) : Stable vacuum pressure (kPa) : Pad area (cm2) : Factor of safety: Horizontal pad contact : 4 (dynamic) Vertical pad contact : 8 (dynamic) W P S t Pad ZM W = P x S x 0.1 x 1 t W ZH W ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Bore size Standard stroke (mm) MM YY L X K W J V H GA GB TA TB U G T F S DA R C Z NN Q B ML P PW YL (mm) 12 16 20 25 18 50 13 5 16 40 58 5 7.5 5 36 29 56 8 22 6 48 29 12 14 39 7 10, 20, 30, 40, 50, 75, 100 M4 x 0.7 10 M4 x 0.7 M5 x 0.8 7 M4 x 0.7 11 22 54 15 7 18 42 64 2.5 8 5.5 38 33 62 8 25 8 52 33 13 16 43 8 10, 20, 30, 40, 50, 75, 100 M5 x 0.8 13 M5 x 0.8 M5 x 0.8 5 M5 x 0.8 11 20, 30
3 e i o w !0 !5 Lateral load resisting type: MQQL (Built-in ball bushing) !1 !6 !
As a rule when W + Pa>PA adjust P so that W + Pa = PA. (2) Installing a regulator with check valve at position (b) can decrease lurching during descent and actuation delay during ascent. As a rule adjust P so that W + PA = Pa.
Without brake C section Brake electric circuit YellowC;*1 Y e l l o w O Y !
Bore size/Stroke (mm) Bore size 6 10 15 20 25 32 Standard strokes 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 Applicable Auto Switches/Refer to page 15 for detailed auto switch specifications.
, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125
Bore size/Stroke (mm) Bore size 6 10 15 20 25 32 Standard strokes 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 Applicable Auto Switches/Refer to page 15 for detailed auto switch specifications.
JM-045 How To Order Seal Kits How To Order Piston Rod Assembly Double Acting Single Rod NC1A W 150 PS NC1A 150 26A 0400 Bore 150 200 250 325 400 Option Single rod W Double rod K* Non-rotating Special Options XB5*** Over sized rod XB6*** High temperature XB7*** Low temperature XB5B6*** Oversized w/ high temperature* XC11 Dual Operation/Single Rod** Stroke (In Inches and Hundredths of
A B W A B W A B W 4.5 (2) 12 16 19 21 17 19 12 12 4 12 4 4 6 4 12 8 8 0 4.5 (2) 16 12 4 12 4 4 6 4 12 8 8 0 Note 1) ( ): D-A96, A9V Note 2) When setting an auto switch, confirm the operation and adjust its mounting position.
Back up spring Poppet spring Note Platinum silver De-energized De-energized q w e Stainless steel r Replacement Parts Part no. No.
13 70 94 11 35 32 50 6.8 11 depth 8 28 16.5 M6 X 1depth12 135 73.5 26.5 118 16 75 15 40 37 50 8.6 14 depth 10 29 160 86.5 31.5 140 104 19 M8 X 1.25 depth 16 75, 100, 125, 150, 200, 250, 300 MXP 16 75 15 40 37 50 8.6 14 depth 10 30 160 86.5 31.5 140 104 19 M8 X 1.25 depth 16 19 18 45 42 80 17 depth 12 35 142 22 M10 X 1.5 depth20 194 170 110 95 37 10.5 MG Bore size (mm) H GR GQ GL O GK J N
30 -40 -50 R(D)QB25-15 -20 -25 -30 -40 -50 R(D)QB32-20 -25 -30 -40 -50 -75 -100 R(D)QB40-20 -25 -30 -40 -50 -75 -100 R(D)QB50-30 -40 -50 -75 -100 9 8 9.5 13.5 10 3 Compact Cylinder with Air Cushion Double Acting: Single Rod Series RQ Auto Switch Mounting Bracket Part Nos.
Nil W Axial Right Left Top Bottom F R L T B Cable length Motor specification 2m 3m 4m 5m 2 3 4 5 Motor output Standard motor Matsushita Electric Industrial Co., Ltd.
1 3 Port Solenoid Valve Metal Seal Series VZ200 Model V100 Large flow capacity Low power consumption: 1.8 W (75 mA, 24 VDC) Plug connector One-touch wiring of plug connectors Common pilot exhaust subplate mounted and manifold Individual exhaust Piping Choice of pilot valve exhaust Type of actuation Common exhaust VZ212 SY VZ212 N.C. Body ported VZ222 VZ222 N.O. N.C. N.O.